메뉴 건너뛰기




Volumn , Issue , 2009, Pages 273-276

Wireless power delivery system for mouse telemeter

Author keywords

[No Author keywords available]

Indexed keywords

BATTERY LIFE; DEVICE OPERATIONS; DEVICE SIZES; HIGH BANDWIDTH; PHYSIOLOGICAL DATA; PHYSIOLOGICAL PARAMETERS; SAMPLE RATE; TELEMETRY SYSTEMS; WIRELESS POWER DELIVERY;

EID: 77749321813     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/BIOCAS.2009.5372030     Document Type: Conference Paper
Times cited : (26)

References (14)
  • 3
    • 42149154894 scopus 로고    scopus 로고
    • Long term, implantable blood pressure monitoring systems
    • J. Potkay, "Long term, implantable blood pressure monitoring systems," Biomedical Microdevices, vol. 10, pp. 379-392, 2008.
    • (2008) Biomedical Microdevices , vol.10 , pp. 379-392
    • Potkay, J.1
  • 4
    • 77749244422 scopus 로고    scopus 로고
    • D. McCormick, M. Lim, R. Kirton, B. Van Vliet, P. Nielsen, D. Budget, and S. Malpas, The role of a gel filled tip in maintaining the frequency response of telemetry based blood pressure measurements, FASEB J., 22, pp. 737.28-, March 1, 2008 2008.
    • D. McCormick, M. Lim, R. Kirton, B. Van Vliet, P. Nielsen, D. Budget, and S. Malpas, "The role of a gel filled tip in maintaining the frequency response of telemetry based blood pressure measurements," FASEB J., vol. 22, pp. 737.28-, March 1, 2008 2008.
  • 7
    • 77749244423 scopus 로고    scopus 로고
    • S. C. Malpas, M. Lim, D. McCormick, R. Kirton, B. Van Vliet, A. Easteal, C. Barrett, S. Guild, and D. Budgett, A novel implantable blood pressure telemetry device; Comparison between Data Sciences and Telemetry Research systems, FASEB J., 22, pp. 738.7-, 2008.
    • S. C. Malpas, M. Lim, D. McCormick, R. Kirton, B. Van Vliet, A. Easteal, C. Barrett, S. Guild, and D. Budgett, "A novel implantable blood pressure telemetry device; Comparison between Data Sciences and Telemetry Research systems," FASEB J., vol. 22, pp. 738.7-, 2008.
  • 8
    • 24944464477 scopus 로고    scopus 로고
    • Inductive powering of a freely moving system
    • B. Lenaerts and R. Puers, "Inductive powering of a freely moving system," Sensors and Actuators A: Physical, vol. 123-124, pp. 522-530, 2005.
    • (2005) Sensors and Actuators A: Physical , vol.123-124 , pp. 522-530
    • Lenaerts, B.1    Puers, R.2
  • 10
    • 33846357446 scopus 로고    scopus 로고
    • An inductive power link for a wireless endoscope
    • B. Lenaerts and R. Puers, "An inductive power link for a wireless endoscope," Biosensors and Bioelectronics, vol. 22, pp. 1390-1395, 2007.
    • (2007) Biosensors and Bioelectronics , vol.22 , pp. 1390-1395
    • Lenaerts, B.1    Puers, R.2
  • 12
    • 0018014292 scopus 로고
    • Wireless powersupplying system for implanted electronic circuits in freely moving animals
    • A. Cools, P. Lambrechts, and J. van Bommel, "Wireless powersupplying system for implanted electronic circuits in freely moving animals," Medical and Biological Engineering and Computing, vol. 16, pp. 559-563, 1978.
    • (1978) Medical and Biological Engineering and Computing , vol.16 , pp. 559-563
    • Cools, A.1    Lambrechts, P.2    van Bommel, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.