메뉴 건너뛰기




Volumn 125, Issue 3, 2010, Pages 830-835

Capsular contracture and possible implant rupture: Is magnetic resonance imaging useful?

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; BREAST ENDOPROSTHESIS; CONTRACTURE; FEMALE; HUMAN; MIDDLE AGED; NUCLEAR MAGNETIC RESONANCE IMAGING; PROSTHESIS FAILURE; RETROSPECTIVE STUDY; RUPTURE;

EID: 77749314947     PISSN: 00321052     EISSN: None     Source Type: Journal    
DOI: 10.1097/PRS.0b013e3181cb6066     Document Type: Article
Times cited : (19)

References (26)
  • 1
    • 0030052048 scopus 로고    scopus 로고
    • Diagnosis of silicone gel breast implant rupture by ultrasonography
    • Chung KC, Beil RJ Jr, et al. Diagnosis of silicone gel breast implant rupture by ultrasonography. Plast Reconstr Surg. 1996; 97:104-109.
    • (1996) Plast Reconstr Surg , vol.97 , pp. 104-109
    • Chung, K.C.1    Beil Jr., R.J.2
  • 2
    • 37349077595 scopus 로고    scopus 로고
    • Breast implant rupture and connective tissue disease: A review of the literature
    • Holmich LR, Lipworth L, Friis S. Breast implant rupture and connective tissue disease: A review of the literature. Plast Reconstr Surg. 2007;120(7 Suppl 1):62S-69S.
    • (2007) Plast Reconstr Surg , vol.120 , Issue.7 SUPPL. 1
    • Holmich, L.R.1    Lipworth, L.2    Friis, S.3
  • 3
    • 4444336293 scopus 로고    scopus 로고
    • Untreated silicone breast implant rupture
    • discussion 215-216
    • Holmich LR, Vejborg IM, Conrad C, et al. Untreated silicone breast implant rupture. Plast Reconstr Surg. 2004;114:204- 214; discussion 215-216.
    • (2004) Plast Reconstr Surg , vol.114 , pp. 204-214
    • Holmich, L.R.1    Vejborg, I.M.2    Conrad, C.3
  • 4
    • 0026683292 scopus 로고
    • The basis of the FDA's decision on breast implant rupture
    • Kessler D. The basis of the FDA's decision on breast implant rupture. N Engl J Med. 1992;326:1713-1715.
    • (1992) N Engl J Med , vol.326 , pp. 1713-1715
    • Kessler, D.1
  • 5
    • 0033796965 scopus 로고    scopus 로고
    • Prevalence of rupture of silicone gel breast implants revealed on MR imaging in a population of women in Birmingham, Alabama
    • Brown SL, Soo MS, Pennello G. Prevalence of rupture of silicone gel breast implants revealed on MR imaging in a population of women in Birmingham, Alabama. AJR Am J Roentgenol. 2000;175:1057-1064.
    • (2000) AJR Am J Roentgenol , vol.175 , pp. 1057-1064
    • Brown, S.L.1    Soo, M.S.2    Pennello, G.3
  • 6
    • 0032446228 scopus 로고    scopus 로고
    • The life span of silicone gel breast implants and a comparison of mammography, ultrasonography, and magnetic resonance imaging in detecting implant rupture: A meta-analysis
    • discussion 585-586
    • Goodman CM, Cohen V, Thornby J, Netscher D. The life span of silicone gel breast implants and a comparison of mammography, ultrasonography, and magnetic resonance imaging in detecting implant rupture: A meta-analysis. Ann Plast Surg. 1998;41:577-585; discussion 585-586.
    • (1998) Ann Plast Surg , vol.41 , pp. 577-585
    • Goodman, C.M.1    Cohen, V.2    Thornby, J.3    Netscher, D.4
  • 7
    • 0042242882 scopus 로고    scopus 로고
    • Incidence of silicone breast implant rupture
    • Holmich LR, Friis S, Fryzek JP, et al. Incidence of silicone breast implant rupture. Arch Surg. 2003;138:801-806.
    • (2003) Arch Surg , vol.138 , pp. 801-806
    • Holmich, L.R.1    Friis, S.2    Fryzek, J.P.3
  • 8
    • 0035884832 scopus 로고    scopus 로고
    • Prevalence of silicone breast implant rupture among Danish women
    • discussion 859-863
    • Holmich LR, Kjøller K, Vejborg I, et al. Prevalence of silicone breast implant rupture among Danish women. Plast Reconstr Surg. 2001;108:848-858; discussion 859-863.
    • (2001) Plast Reconstr Surg , vol.108 , pp. 848-858
    • Holmich, L.R.1    Kjøller, K.2    Vejborg, I.3
  • 9
    • 0036150654 scopus 로고    scopus 로고
    • MR imaging of extracapsular silicone from breast implants: Diagnostic pitfalls
    • Berg WA, Soo MS, Pennello G. MR imaging of extracapsular silicone from breast implants: Diagnostic pitfalls. AJR Am J Roentgenol. 2002;178:465-472.
    • (2002) AJR Am J Roentgenol , vol.178 , pp. 465-472
    • Berg, W.A.1    Soo, M.S.2    Pennello, G.3
  • 10
    • 0034791076 scopus 로고    scopus 로고
    • MRI for detecting silicone breast implant rupture: Meta-analysis and implications
    • Cher DJ, Conwell JA, Mandel JS. MRI for detecting silicone breast implant rupture: Meta-analysis and implications. Ann Plast Surg. 2001;47:367-380.
    • (2001) Ann Plast Surg , vol.47 , pp. 367-380
    • Cher, D.J.1    Conwell, J.A.2    Mandel, J.S.3
  • 11
    • 0141833136 scopus 로고    scopus 로고
    • Available at: Accessed June 12, 2009
    • U.S. Food and Drug Administration. Guidance for Industry and FDA Staff: Saline, Silicone Gel, and Alternative Breast Implants. 2006. Available at: https://imail.mayo.edu/exchweb/bin/redir.asp? URL=http://www.fda.gov/ MedicalDevices/DeviceRegulation andGuidance/GuidanceDocuments/ucm071228.htm. Accessed June 12, 2009.
    • (2006) Guidance for Industry and FDA Staff: Saline Silicone Gel and Alternative Breast Implants
  • 13
    • 0026495866 scopus 로고
    • Screening mammography in 350 women with breast implants: Prevalence and findings of implant complications
    • discussion 979-981
    • Destouet JM, Monsees BS, Oser RF, Nemecek JR, Pilgram TK. Screening mammography in 350 women with breast implants: Prevalence and findings of implant complications. AJR Am J Roentgenol. 1992;159:973-978; discussion 979-981.
    • (1992) AJR Am J Roentgenol , vol.159 , pp. 973-978
    • Destouet, J.M.1    Monsees, B.S.2    Oser, R.F.3    Nemecek, J.R.4    Pilgram, T.K.5
  • 14
    • 0028012524 scopus 로고
    • Silicone breast implant ruptures in an animal model: Comparison of mammography, MR imaging, US, and CT
    • Gorczyca DP, DeBruhl ND, Ahn CY, et al. Silicone breast implant ruptures in an animal model: Comparison of mammography, MR imaging, US, and CT. Radiology. 1994;190: 227-232.
    • (1994) Radiology , vol.190 , pp. 227-232
    • Gorczyca, D.P.1    Debruhl, N.D.2    Ahn, C.Y.3
  • 15
    • 0029968739 scopus 로고    scopus 로고
    • Diagnostic value of clinical examination and various imaging techniques for breast implant rupture as determined in 81 patients having implant removal
    • Netscher DT, Weizer G, Thornby J. Diagnostic value of clinical examination and various imaging techniques for breast implant rupture as determined in 81 patients having implant removal. South Med J. 1996;89:397-404.
    • (1996) South Med J , vol.89 , pp. 397-404
    • Netscher, D.T.1    Weizer, G.2    Thornby, J.3
  • 16
    • 0033783082 scopus 로고    scopus 로고
    • Imaging spectrum of breast implant complications: Mammography, ultrasound, and magnetic resonance imaging
    • O'Toole M, Caskey CI. Imaging spectrum of breast implant complications: Mammography, ultrasound, and magnetic resonance imaging. Semin Ultrasound CT MR. 2000;21:351-361.
    • (2000) Semin Ultrasound CT MR , vol.21 , pp. 351-361
    • O'Toole, M.1    Caskey, C.I.2
  • 17
    • 37349085816 scopus 로고    scopus 로고
    • Inamed silicone breast implant U.S. study group: Inamed silicone breast implant core study results at 6 years
    • discussion 17S-18S
    • Spear SL, Murphy DK, Slicton A, Walker PS. Inamed Silicone Breast Implant U.S. Study Group: Inamed silicone breast implant core study results at 6 years. Plast Reconstr Surg. 2007; 120(7 Suppl. 1):8S-16S; discussion 17S-18S.
    • (2007) Plast Reconstr Surg , vol.120 , Issue.7 SUPPL. 1
    • Spear, S.L.1    Murphy, D.K.2    Slicton, A.3    Walker, P.S.4
  • 18
    • 67349285721 scopus 로고    scopus 로고
    • Safety and effectiveness of Mentor's MemoryGel implants at 6 years
    • Cunningham B, McCue J. Safety and effectiveness of Mentor's MemoryGel implants at 6 years. Aesthet Plast Surg. 2009; 33:440-444.
    • (2009) Aesthet Plast Surg , vol.33 , pp. 440-444
    • Cunningham, B.1    McCue, J.2
  • 19
    • 0028027976 scopus 로고
    • Comparative silicone breast implant evaluation using mammography, sonography, and magnetic resonance imaging: Experience with 59 implants
    • Ahn CY, DeBruhl ND, Gorczyca DP, Shaw WW, Bassett LW. Comparative silicone breast implant evaluation using mammography, sonography, and magnetic resonance imaging: Experience with 59 implants. Plast Reconstr Surg. 1994;94:620-627.
    • (1994) Plast Reconstr Surg , vol.94 , pp. 620-627
    • Ahn, C.Y.1    Debruhl, N.D.2    Gorczyca, D.P.3    Shaw, W.W.4    Bassett, L.W.5
  • 20
    • 0026661919 scopus 로고
    • Silicone breast implants in vivo: MR imaging
    • Gorczyca DP, Sinha S, Ahn CY, et al. Silicone breast implants in vivo: MR imaging. Radiology 1992;185:407-410.
    • (1992) Radiology , vol.185 , pp. 407-410
    • Gorczyca, D.P.1    Sinha, S.2    Ahn, C.Y.3
  • 21
    • 0027688766 scopus 로고
    • Diagnosing breast implant rupture with MR imaging, US, and mammography
    • Berg WA, Caskey CI, Hamper UM, et al. Diagnosing breast implant rupture with MR imaging, US, and mammography. Radiographics 1993;13:1323-1336.
    • (1993) Radiographics , vol.13 , pp. 1323-1336
    • Berg, W.A.1    Caskey, C.I.2    Hamper, U.M.3
  • 23
    • 0032695136 scopus 로고    scopus 로고
    • Silicone breast implant rupture: Pitfalls of magnetic resonance imaging and relative efficacies of magnetic resonance, mammography, and ultrasound
    • Ikeda DM, Borofsky HB, Herfkens RJ. Silicone breast implant rupture: Pitfalls of magnetic resonance imaging and relative efficacies of magnetic resonance, mammography, and ultrasound. Plast Reconstr Surg. 1999;104:2054-2062.
    • (1999) Plast Reconstr Surg , vol.104 , pp. 2054-2062
    • Ikeda, D.M.1    Borofsky, H.B.2    Herfkens, R.J.3
  • 24
    • 19444362236 scopus 로고    scopus 로고
    • The diagnosis of silicone breast-implant rupture: Clinical findings compared with findings at magnetic resonance imaging
    • Holmich LR, Fryzek JP, Kjøller K, et al. The diagnosis of silicone breast-implant rupture: Clinical findings compared with findings at magnetic resonance imaging. Ann Plast Surg. 2005;54:583-589.
    • (2005) Ann Plast Surg , vol.54 , pp. 583-589
    • Holmich, L.R.1    Fryzek, J.P.2    Kjøller, K.3
  • 25
    • 0031687166 scopus 로고    scopus 로고
    • Decision-analysis methodology in the work-up of women with suspected silicone breast implant rupture
    • Chung KC, Greenfield ML, Walters M. Decision-analysis methodology in the work-up of women with suspected silicone breast implant rupture. Plast Reconstr Surg. 1998;102:689-695.
    • (1998) Plast Reconstr Surg , vol.102 , pp. 689-695
    • Chung, K.C.1    Greenfield, M.L.2    Walters, M.3
  • 26
    • 0031711934 scopus 로고    scopus 로고
    • Capsular calcification associated with silicone breast implants: Incidence, determinants, and characterization
    • Peters W, Pritzker K, Smith D, et al. Capsular calcification associated with silicone breast implants: Incidence, determinants, and characterization Ann Plast Surg. 1998;41: 348-360.
    • (1998) Ann Plast Surg , vol.41 , pp. 348-360
    • Peters, W.1    Pritzker, K.2    Smith, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.