메뉴 건너뛰기




Volumn , Issue , 2006, Pages 207-226

Modelling, Analysis and Fabrication of Below-knee Prosthetic Sockets Using Rapid Prototyping

Author keywords

Computer aided modelling; Fabrication of below knee prosthetic socket; Finite element analysis (FEA); Prosthetic rectification; Prosthetic socket interface stress; Socket accuracy

Indexed keywords


EID: 77749307586     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1002/0470033983.ch10     Document Type: Chapter
Times cited : (5)

References (15)
  • 1
    • 0041047463 scopus 로고
    • Abaqus, Version 5.5, ABAQUS, Inc., Rhode Island
    • Abaqus (1995) ABAQUS/Standard User's Manual, Version 5.5, ABAQUS, Inc., Rhode Island.
    • (1995) ABAQUS/Standard User's Manual
  • 2
    • 0030414950 scopus 로고    scopus 로고
    • Rapid prototyping from a computer scientist's point-of-view
    • Dolenc, A. and Mäkelä, I. (1996) Rapid prototyping from a computer scientist's point-of-view. Rapid Prototyping J., 2(2),18-25.
    • (1996) Rapid Prototyping J. , vol.2 , Issue.2 , pp. 18-25
    • Dolenc, A.1    Mäkelä, I.2
  • 3
    • 0030418571 scopus 로고    scopus 로고
    • Accuracy issues in CAD to RP translations
    • Georges, M. F. and Chuck, K. (1996) Accuracy issues in CAD to RP translations. Rapid Prototyping J., 2(2),4-17.
    • (1996) Rapid Prototyping J. , vol.2 , Issue.2 , pp. 4-17
    • Georges, M.F.1    Chuck, K.2
  • 4
    • 84889435121 scopus 로고    scopus 로고
    • Imageware Version 5.0, Imageware, Inc., San Diego
    • Imageware (1996) SURFACER Training Guide, Version 5.0, Imageware, Inc., San Diego.
    • (1996) SURFACER Training Guide
  • 6
    • 84889419365 scopus 로고    scopus 로고
    • Research and Development Department of Otto Bock Orthopadische Industrie GmbH Duderstadt, West Germany
    • Otto Bock (1996) Otto Bock modular below knee prostheses. Research and Development Department of Otto Bock Orthopadische Industrie GmbH Duderstadt, West Germany.
    • (1996) Otto Bock modular below knee prostheses
    • Bock, O.1
  • 7
    • 0025946787 scopus 로고
    • Analysis of a below-knee patellar tendon-bearing prosthesis: a finite element study
    • Quesada, P. and Skinner, H. B. (1991) Analysis of a below-knee patellar tendon-bearing prosthesis: a finite element study. J. Rehabil. Res. and Dev., 28(3),1-12.
    • (1991) J. Rehabil. Res. and Dev. , vol.28 , Issue.3 , pp. 1-12
    • Quesada, P.1    Skinner, H.B.2
  • 8
    • 0027752359 scopus 로고
    • Normal and shear stresses on a residual limb in a prosthetic socket during ambulation: Comparison of finite element results with experimental measurements
    • Sanders, J. E. and Daly, C. H. (1993) Normal and shear stresses on a residual limb in a prosthetic socket during ambulation: Comparison of finite element results with experimental measurements. J. Rehabil. Res. and Dev., 30(2),191-204.
    • (1993) J. Rehabil. Res. and Dev. , vol.30 , Issue.2 , pp. 191-204
    • Sanders, J.E.1    Daly, C.H.2
  • 9
    • 0027752359 scopus 로고
    • Interface shear stress during ambulation with below-knee prosthetic limb
    • Sanders, J. E., Daly, C. H. and Burgess, E. M. (1993) Interface shear stress during ambulation with below-knee prosthetic limb. J. Rehabil. Res. and Dev., 30(2),191-204.
    • (1993) J. Rehabil. Res. and Dev. , vol.30 , Issue.2 , pp. 191-204
    • Sanders, J.E.1    Daly, C.H.2    Burgess, E.M.3
  • 10
    • 0030200561 scopus 로고    scopus 로고
    • Parametric analysis using the finite element method to investigate prosthetic interface stresses for persons with trans-tibial amputation
    • Silver-Thorn, M. B. and Childress, D. S. (1996) Parametric analysis using the finite element method to investigate prosthetic interface stresses for persons with trans-tibial amputation. J. Rehabil. Res. and Dev., 33(3),227-38.
    • (1996) J. Rehabil. Res. and Dev. , vol.33 , Issue.3 , pp. 227-238
    • Silver-Thorn, M.B.1    Childress, D.S.2
  • 11
    • 0023513060 scopus 로고
    • Dynamic testing of below-knee prosthesis: assembly and components
    • Wevers, H. W. and Durance, J. P. (1987) Dynamic testing of below-knee prosthesis: assembly and components. Prosthetics and Orthotics Int., 11,117-23.
    • (1987) Prosthetics and Orthotics Int. , vol.11 , pp. 117-123
    • Wevers, H.W.1    Durance, J.P.2
  • 12
    • 0036459080 scopus 로고    scopus 로고
    • Structural integrity of polypropylene prosthetic sockets manufactured using the polymer deposition technique
    • Goh, J. C., Lee, P. V. and Ng, P. (2002) Structural integrity of polypropylene prosthetic sockets manufactured using the polymer deposition technique. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 216(6),359-68.
    • (2002) Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine , vol.216 , Issue.6 , pp. 359-368
    • Goh, J.C.1    Lee, P.V.2    Ng, P.3
  • 14
    • 0036095497 scopus 로고    scopus 로고
    • Prosthetic sockets fabrication using rapid prototyping technology
    • Ng, P., Lee, V. S. P. and Goh, J. C. H. (2002) Prosthetic sockets fabrication using rapid prototyping technology. Rapid Prototyping J., 8(1),53-9.
    • (2002) Rapid Prototyping J. , vol.8 , Issue.1 , pp. 53-59
    • Ng, P.1    Lee, V.S.P.2    Goh, J.C.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.