메뉴 건너뛰기




Volumn 60, Issue 2, 2010, Pages 204-209

Use of passive diffusion tubes to monitor air pollutants

Author keywords

[No Author keywords available]

Indexed keywords

CARBON MONOXIDE; NITROGEN OXIDES; SULFUR DIOXIDE; TUBES (COMPONENTS);

EID: 77749296047     PISSN: 10962247     EISSN: 21622906     Source Type: Journal    
DOI: 10.3155/1047-3289.60.2.204     Document Type: Article
Times cited : (17)

References (17)
  • 1
    • 77949531066 scopus 로고    scopus 로고
    • available at, accessed 2009
    • What Are the Six Common Air Pollutants?; U.S. Environmental Protection Agency; available at http://www.epa.gov/air/urbanair (accessed 2009).
    • What Are the Six Common Air Pollutants
  • 3
    • 23844464045 scopus 로고    scopus 로고
    • Proceedings of the Hydrogen Sulfide Health Research and Risk Assessment Symposium; October 31-November 2, 2000
    • Woodall, G.M., Jr.; Smith, R.L.; Granville, G.C. Proceedings of the Hydrogen Sulfide Health Research and Risk Assessment Symposium; October 31-November 2, 2000; Inhal. Toxicol. 2005, 17, 593-639.
    • (2005) Inhal. Toxicol , vol.17 , pp. 593-639
    • Woodall Jr., G.M.1    Smith, R.L.2    Granville, G.C.3
  • 4
    • 0042330301 scopus 로고    scopus 로고
    • 2: A Review and Some Case Studies
    • 2: a Review and Some Case Studies; Environ. Pollut. 2003, 126, 301-311.
    • (2003) Environ. Pollut , vol.126 , pp. 301-311
    • Cox, R.M.1
  • 5
    • 49949089385 scopus 로고    scopus 로고
    • Passive Dosimeters for Nitrogen Dioxide in Personal/Indoor Air Sampling: A Review
    • Chang, H.Y.; Morandi, M.T.; Weisel, C.P. Passive Dosimeters for Nitrogen Dioxide in Personal/Indoor Air Sampling: a Review; J. Expo. Anal. Environ. Epidemiol. 2008, 18, 441-451.
    • (2008) J. Expo. Anal. Environ. Epidemiol , vol.18 , pp. 441-451
    • Chang, H.Y.1    Morandi, M.T.2    Weisel, C.P.3
  • 7
    • 0036064908 scopus 로고    scopus 로고
    • An Analysis of Factors that Influence Personal Exposure to Nitrogen Oxides in Residents of Richmond, Virginia
    • Zipprich, J.L.; Harris, S.A.; Fox, J.C.; Borzelleca, J.F. An Analysis of Factors that Influence Personal Exposure to Nitrogen Oxides in Residents of Richmond, Virginia; J. Expo. Anal. Environ. Epidemiol. 2002, 12, 273-285.
    • (2002) J. Expo. Anal. Environ. Epidemiol , vol.12 , pp. 273-285
    • Zipprich, J.L.1    Harris, S.A.2    Fox, J.C.3    Borzelleca, J.F.4
  • 9
    • 34548280435 scopus 로고    scopus 로고
    • Determination of Ozone in Outdoor and Indoor Environments Using Nitrite-Impregnated Passive Samplers Followed by Ion Chromatography
    • doi: 10.3155/1047-3289.57.8.974
    • Karthikeyan, S.; Perumal, S.; Balasubramanian, R.; Zuraimi, M.; Tham, K. Determination of Ozone in Outdoor and Indoor Environments Using Nitrite-Impregnated Passive Samplers Followed by Ion Chromatography; J. Air & Waste Manage. Assoc. 2007, 57, 974-980; doi: 10.3155/1047-3289.57.8.974.
    • (2007) J. Air & Waste Manage. Assoc , vol.57 , pp. 974-980
    • Karthikeyan, S.1    Perumal, S.2    Balasubramanian, R.3    Zuraimi, M.4    Tham, K.5
  • 14
    • 0035133801 scopus 로고    scopus 로고
    • Influence of Environmental Parameters on the Accuracy of Nitrogen Dioxide Passive Diffusion Tubes for Ambient Measurement
    • Kirby, C.; Fox, M.; Waterhouse, J.; Drye, T. Influence of Environmental Parameters on the Accuracy of Nitrogen Dioxide Passive Diffusion Tubes for Ambient Measurement; J. Environ. Monit. 2001, 3, 150-158.
    • (2001) J. Environ. Monit , vol.3 , pp. 150-158
    • Kirby, C.1    Fox, M.2    Waterhouse, J.3    Drye, T.4
  • 15
    • 58149396114 scopus 로고    scopus 로고
    • Mukerjee, S.; Oliver, K.D.; Seila, R.L.; Jacumin, H.H., Jr.; Croghan, C.; Daughtrey, E.H., Jr.; Neas, L.M.; Smith, L.A. Field Comparison of Passive Samplers with Reference Monitors for Ambient Volatile Organic Compounds and Nitrogen Dioxide under Week-Long Integrals; J. Environ. Monit. 2009, 11, 220-227.
    • Mukerjee, S.; Oliver, K.D.; Seila, R.L.; Jacumin, H.H., Jr.; Croghan, C.; Daughtrey, E.H., Jr.; Neas, L.M.; Smith, L.A. Field Comparison of Passive Samplers with Reference Monitors for Ambient Volatile Organic Compounds and Nitrogen Dioxide under Week-Long Integrals; J. Environ. Monit. 2009, 11, 220-227.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.