-
1
-
-
0035283698
-
Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformal irradiation of carcinoma of the prostate
-
DOI 10.1016/S0360-3016(00)01446-2, PII S0360301600014462
-
H. Alasti, " Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformal irradiation of carcinoma of the prostate.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 49, 869-884 (2001). 10.1016/S0360-3016(00)01446-2 (Pubitemid 32112210)
-
(2001)
International Journal of Radiation Oncology Biology Physics
, vol.49
, Issue.3
, pp. 869-884
-
-
Alasti, H.1
Petric M.Peter2
Catton, C.N.3
Warde, P.R.4
-
2
-
-
0031783649
-
Prostate target volume variations during a course of radiotherapy
-
DOI 10.1016/S0360-3016(98)00248-X, PII S036030169800248X
-
J. Antolak, " Prostate target volume variations during a course of radiotherapy.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 42, 661-672 (1998). 10.1016/S0360-3016(98)00248-X (Pubitemid 28501118)
-
(1998)
International Journal of Radiation Oncology Biology Physics
, vol.42
, Issue.3
, pp. 661-672
-
-
Antolak, J.A.1
Rosen, I.I.2
Childress, C.H.3
Zagars, G.K.4
Pollack, A.5
-
3
-
-
0030061461
-
Analysis of prostate and seminal vesicle motion: Implications for treatment planning
-
DOI 10.1016/0360-3016(95)02081-0
-
C. J. Beard, " Analysis of prostate and seminal vesicle motion: Implications for treatment planning.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 34, 451-458 (1996). 10.1016/0360-3016(95)02081-0 (Pubitemid 26031592)
-
(1996)
International Journal of Radiation Oncology Biology Physics
, vol.34
, Issue.2
, pp. 451-458
-
-
Beard, C.J.1
Kijewski, P.2
Bussiere, M.3
Gelman, R.4
Gladstone, D.5
Shaffer, K.6
Plunkett, M.7
Costello, P.8
Coleman, C.N.9
-
4
-
-
23844553577
-
A review of prostate motion with considerations for the treatment of prostate cancer
-
DOI 10.1016/j.meddos.2005.03.005, PII S0958394705001007
-
T. E. Byrne, " A review of prostate motion with considerations for the treatment of prostate cancer.," Med. Dosim. ZZZZZZ 0739-0211 30, 155-161 (2005). 10.1016/j.meddos.2005.03.005 (Pubitemid 41160455)
-
(2005)
Medical Dosimetry
, vol.30
, Issue.3
, pp. 155-161
-
-
Byrne, T.E.1
-
5
-
-
0000933454
-
Evaluation of changes in the location and shape of the prostate and rectum during a seven week course of conformal radiotherapy
-
IOBPD3 0360-3016,. 10.1016/0360-3016(93)90783-R
-
J. D. Forma, " Evaluation of changes in the location and shape of the prostate and rectum during a seven week course of conformal radiotherapy.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 27, 222-222 (1993). 10.1016/0360-3016(93)90783-R
-
(1993)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.27
, pp. 222-222
-
-
Forma, J.D.1
-
6
-
-
0030932845
-
Measurement of patient positioning errors in three-dimensional conformal radiotherapy of the prostate
-
DOI 10.1016/S0360-3016(96)00526-3, PII S0360301696005263
-
J. Hanley, " Measurement of patient positioning errors in three-dimensional conformal radiotherapy of the prostate.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 37, 435-444 (1997). 10.1016/S0360- 3016(96)00526-3 (Pubitemid 27138731)
-
(1997)
International Journal of Radiation Oncology Biology Physics
, vol.37
, Issue.2
, pp. 435-444
-
-
Hanley, J.1
Lumley, M.A.2
Mageras, G.S.3
Sun, J.4
Zelefsky, M.J.5
Leibel, S.A.6
Fuks, Z.7
Kutcher, G.J.8
-
7
-
-
33748945694
-
Daily variations in delivered doses in patients treated with radiotherapy for localized prostate cancer
-
IOBPD3 0360-3016,. 10.1016/j.ijrob2006.06.011
-
P. Kupelian, " Daily variations in delivered doses in patients treated with radiotherapy for localized prostate cancer.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 66, 876-882 (2006). 10.1016/j.ijrobp.2006. 06.011
-
(2006)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.66
, pp. 876-882
-
-
Kupelian, P.1
-
8
-
-
0038503664
-
Use of portal images and BAT ultrasonography to measure setup error and organ motion for prostate IMRT: Implications for treatment margins
-
DOI 10.1016/S0360-3016(03)00290-6
-
D. J. Little, " Use of portal images and BAT ultrasonography to measure setup error and organ motion for prostate IMRT: Implications for treatment margins.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 56, 1218-1224 (2003). 10.1016/S0360-3016(03)00290-6 (Pubitemid 36842871)
-
(2003)
International Journal of Radiation Oncology Biology Physics
, vol.56
, Issue.5
, pp. 1218-1224
-
-
Little, D.J.1
Dong, L.2
Levy, L.B.3
Chandra, A.4
Kuban, D.A.5
-
9
-
-
7244252932
-
The impact of daily shifts on prostate IMRT dose distributions
-
DOI 10.1118/1.1784592
-
N. P. Orton and W. A. Tome, " The impact of daily shifts on prostate IMRT dose distributions.," Med. Phys. MPHYA6 0094-2405 31 (10), 2845-2848 (2004). 10.1118/1.1784592 (Pubitemid 39431013)
-
(2004)
Medical Physics
, vol.31
, Issue.10
, pp. 2845-2848
-
-
Orton, N.P.1
Tome, W.A.2
-
10
-
-
0027564490
-
Movements of the prostate due to rectal and bladder distension: Implication for radiotherapy
-
ZZZZZZ 0739-0211.
-
S. E. Schild, H. E. Casale, and L. P. Bellefontaine, " Movements of the prostate due to rectal and bladder distension: Implication for radiotherapy.," Med. Dosim. ZZZZZZ 0739-0211 18, 13-15 (1993).
-
(1993)
Med. Dosim.
, vol.18
, pp. 13-15
-
-
Schild, S.E.1
Casale, H.E.2
Bellefontaine, L.P.3
-
11
-
-
0034100976
-
Detection of internal organ movement in prostate cancer patients using portal images
-
DOI 10.1118/1.598913
-
J. C. Stroom, " Detection of internal organ movement in prostate cancer patients using portal images.," Med. Phys. MPHYA6 0094-2405 27 (3), 452-461 (2000). 10.1118/1.598913 (Pubitemid 30171793)
-
(2000)
Medical Physics
, vol.27
, Issue.3
, pp. 452-461
-
-
Stroom, J.C.1
Kroonwijk, M.2
Pasma, K.L.3
Koper, P.C.M.4
Van Dieren, E.B.5
Heijmen, B.J.M.6
-
12
-
-
0025779040
-
Treatment planning issues related to prostate movement in response to differential filling of the rectum and bladder
-
IOBPD3 0360-3016,. 10.1016/0360-3016(91)90244-X
-
R. K. Ten Haken, " Treatment planning issues related to prostate movement in response to differential filling of the rectum and bladder.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 20, 1317-1324 (1991). 10.1016/0360-3016(91)90244-X
-
(1991)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.20
, pp. 1317-1324
-
-
Ten Haken, R.K.1
-
13
-
-
0032917307
-
Quantification and predictors of prostate position variability in 50 patients evaluated with multiple CT scans during conformal radiotherapy
-
DOI 10.1016/S0167-8140(99)00011-0, PII S0167814099000110
-
M. J. Zelefsky, " Quantification and predictors of prostate position variability in 50 patients evaluated with multiple CT scans during conformal radiotherapy.," Radiother. Oncol. RAONDT 0167-8140 50, 225-234 (1999). 10.1016/S0167-8140(99)00011-0 (Pubitemid 29155549)
-
(1999)
Radiotherapy and Oncology
, vol.50
, Issue.2
, pp. 225-234
-
-
Zelefsky, M.J.1
Crean, D.2
Mageras, G.S.3
Lyass, O.4
Happersett, L.5
Clifton Ling, C.6
Leibel, S.A.7
Fuks, Z.8
Bull, S.9
Kooy, H.M.10
Van Herk, M.11
Kutcher, G.J.12
-
14
-
-
77749279081
-
Evaluation of inter- and intrafraction organ motion during intensity modulated radiation therapy (IMRT) for localized prostate cancer measured by a newly developed on-board image-guided system
-
ZZZZZZ 0288-2043.
-
K. Britton, " Evaluation of inter- and intrafraction organ motion during intensity modulated radiation therapy (IMRT) for localized prostate cancer measured by a newly developed on-board image-guided system.," Radiat. Med. ZZZZZZ 0288-2043 30, 155-161 (2005).
-
(2005)
Radiat. Med.
, vol.30
, pp. 155-161
-
-
Britton, K.1
-
15
-
-
0036680142
-
Locoregional treatment outcomes for inoperable anthracycline-resistant breast cancer
-
DOI 10.1016/S0360-3016(02)02878-X, PII S036030160202878X
-
E. Huang, " Intrafraction prostate motion during IMRT for prostate cancer.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 53, 261-268 (2002). 10.1016/S0360-3016(02)02878-X (Pubitemid 34787859)
-
(2002)
International Journal of Radiation Oncology Biology Physics
, vol.53
, Issue.5
, pp. 1225-1233
-
-
Huang, E.1
McNeese, M.D.2
Strom, E.A.3
Perkins, G.H.4
Katz, A.5
Hortobagyi, G.N.6
Valero, V.7
Kuerer, H.M.8
Singletary S.Eva9
Hunt, K.K.10
Buzdar, A.U.11
Buchholz, T.A.12
-
16
-
-
0028784185
-
Evaluation of changes in the size and location of the prostate, seminal vesicles, bladder, and rectum during a course of external beam radiation therapy
-
IOBPD3 0360-3016 (),. 10.1016/0360-3016(95)00225-1
-
J. C. Roeske, " Evaluation of changes in the size and location of the prostate, seminal vesicles, bladder, and rectum during a course of external beam radiation therapy.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 33 (5), 1321-1329 (1995). 10.1016/0360-3016(95)00225-1
-
(1995)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.33
, Issue.5
, pp. 1321-1329
-
-
Roeske, J.C.1
-
17
-
-
10044223321
-
Online image-guided intensity-modulated radiotherapy for prostate cancer: How much improvement can we expect? A theoretical assessment of clinical benefits and potential dose escalation by improving precision and accuracy of radiation delivery
-
IOBPD3 0360-3016,. 10.1016/j.ijrob2004.07.342
-
M. Ghilezan, " Online image-guided intensity-modulated radiotherapy for prostate cancer: How much improvement can we expect? A theoretical assessment of clinical benefits and potential dose escalation by improving precision and accuracy of radiation delivery.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 60, 1602-1610 (2004). 10.1016/j.ijrobp.2004.07.342
-
(2004)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.60
, pp. 1602-1610
-
-
Ghilezan, M.1
-
18
-
-
0032866087
-
A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets
-
DOI 10.1016/S0360-3016(99)00118-2, PII S0360301699001182
-
D. A. Jaffray, " A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 45, 773-789 (1999). 10.1016/S0360-3016(99)00118-2 (Pubitemid 29462661)
-
(1999)
International Journal of Radiation Oncology Biology Physics
, vol.45
, Issue.3
, pp. 773-789
-
-
Jaffray, D.A.1
Drake, D.G.2
Moreau, M.3
Martinez, A.A.4
Wong, J.W.5
-
19
-
-
32744459742
-
Using daily MVCT images to calculate daily rectal dose volume histograms in prostate cancer patients treated with a helical tomotherapy unit
-
IOBPD3 0360-3016,. 10.1016/j.ijrob2004.07.620
-
K. Langen, " Using daily MVCT images to calculate daily rectal dose volume histograms in prostate cancer patients treated with a helical tomotherapy unit.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 60, S613 (2004). 10.1016/j.ijrobp.2004.07.620
-
(2004)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.60
, pp. 613
-
-
Langen, K.1
-
20
-
-
22144485867
-
Initial experience with megavoltage (MV) CT guidance for daily prostate alignments
-
IOBPD3 0360-3016,. 10.1016/j.ijrob2005.02.047
-
K. Langen, " Initial experience with megavoltage (MV) CT guidance for daily prostate alignments.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 62, 1517-1524 (2005). 10.1016/j.ijrobp.2005.02.047
-
(2005)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.62
, pp. 1517-1524
-
-
Langen, K.1
-
21
-
-
27144520502
-
Automatic prostate localization on cone-beam CT scans for high precision image-guided radiotherapy
-
IOBPD3 0360-3016,. 10.1016/j.ijrob2005.07.973
-
M. H. P. Smitsmans, " Automatic prostate localization on cone-beam CT scans for high precision image-guided radiotherapy.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 63, 975-984 (2005). 10.1016/j.ijrobp.2005. 07.973
-
(2005)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.63
, pp. 975-984
-
-
Smitsmans, M.H.P.1
-
22
-
-
12844261801
-
Image-guided radiotherapy for prostate cancer by CT-linear accelerator combination: Prostate movements and dosimetric considerations
-
IOBPD3 0360-3016,. 10.1016/j.ijrob2004.06.010
-
J. R. Wong, " Image-guided radiotherapy for prostate cancer by CT-linear accelerator combination: Prostate movements and dosimetric considerations.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 61, 561-569 (2005). 10.1016/j.ijrobp.2004.06.010
-
(2005)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.61
, pp. 561-569
-
-
Wong, J.R.1
-
23
-
-
33751177982
-
Dosimetric feasibility of cone-beam CT-based treatment planning compared to CT-based treatment planning
-
IOBPD3 0360-3016 (),. 10.1016/j.ijrob2006.08.031
-
S. Yoo and F. Yin, " Dosimetric feasibility of cone-beam CT-based treatment planning compared to CT-based treatment planning.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 66 (5), 1553-1561 (2006). 10.1016/j.ijrobp.2006.08.031
-
(2006)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.66
, Issue.5
, pp. 1553-1561
-
-
Yoo, S.1
Yin, F.2
-
24
-
-
41849130277
-
On-line re-optimization of prostate IMRT plans for adaptive radiation therapy
-
PHMBA7 0031-9155,. 10.1088/0031-9155/53/3/011
-
Q. J. Wu, " On-line re-optimization of prostate IMRT plans for adaptive radiation therapy.," Phys. Med. Biol. PHMBA7 0031-9155 53, 673-691 (2008). 10.1088/0031-9155/53/3/011
-
(2008)
Phys. Med. Biol.
, vol.53
, pp. 673-691
-
-
Wu, Q.J.1
-
25
-
-
0035384866
-
Consistent image registration
-
ITMID4 0278-0062 (),. 10.1109/42.932742
-
G. E. Christensen and H. J. Johnson, " Consistent image registration.," IEEE Trans. Med. Imaging ITMID4 0278-0062 20 (7), 568-582 (2001). 10.1109/42.932742
-
(2001)
IEEE Trans. Med. Imaging
, vol.20
, Issue.7
, pp. 568-582
-
-
Christensen, G.E.1
Johnson, H.J.2
-
26
-
-
7044260966
-
Unbiased diffeomorphic atlas construction for computational anatomy
-
DOI 10.1016/j.neuroimage.2004.07.068, PII S1053811904003842, Mathematics in Brain Imaging
-
S. Joshi, " Unbiased diffeomorphic atlas construction for computational anatomy.," Neuroimage ZZZZZZ 1053-8119 23, S151-S160 (2004). 10.1016/j.neuroimage.2004.07.068 (Pubitemid 39421714)
-
(2004)
NeuroImage
, vol.23
, Issue.SUPPL. 1
-
-
Joshi, S.1
Davis, B.2
Jomier, M.3
Gerig, G.4
-
27
-
-
58149235042
-
A fast inverse consistent deformable image registration method based on symmetric optical flow computation
-
PHMBA7 0031-9155,. 10.1088/0031-9155/53/21/017
-
D. Yang, " A fast inverse consistent deformable image registration method based on symmetric optical flow computation.," Phys. Med. Biol. PHMBA7 0031-9155 53, 6143-6165 (2008). 10.1088/0031-9155/53/21/017
-
(2008)
Phys. Med. Biol.
, vol.53
, pp. 6143-6165
-
-
Yang, D.1
-
28
-
-
20044387033
-
Validation of an accelerated 'demons' algorithm for deformable image registration in radiation therapy
-
DOI 10.1088/0031-9155/50/12/011
-
H. Wang, " Validation of an accelerated demons' algorithm for deformable image registration in radiation therapy.," Phys. Med. Biol. PHMBA7 0031-9155 50, 2887-2905 (2005). 10.1088/0031-9155/50/12/011 (Pubitemid 40771018)
-
(2005)
Physics in Medicine and Biology
, vol.50
, Issue.12
, pp. 2887-2905
-
-
Wang, H.1
Dong, L.2
O'Daniel, J.3
Mohan, R.4
Garden, A.S.5
Kian Ang, K.6
Kuban, D.A.7
Bonnen, M.8
Chang, J.Y.9
Cheung, R.10
-
29
-
-
38349013410
-
Hybrid multiscale landmark and deformable image registration
-
ZZZZZZ 1547-1063 ().
-
D. Paqin, D. Levy, and L. Xing, " Hybrid multiscale landmark and deformable image registration.," Math. Biosci. Eng. ZZZZZZ 1547-1063 17 (4), 711-737 (2007).
-
(2007)
Math. Biosci. Eng.
, vol.17
, Issue.4
, pp. 711-737
-
-
Paqin, D.1
Levy, D.2
Xing, L.3
-
30
-
-
40049094996
-
How does CT image noise affect 3D deformable image registration for image-guided radiotherapy planning?
-
DOI 10.1118/1.2837292
-
M. J. Murphy, " How does CT image noise affect 3D deformable image registration for image-guided radiotherapy planning.," Med. Phys. MPHYA6 0094-2405 35 (3), 1145-1153 (2008). 10.1118/1.2837292 (Pubitemid 351322660)
-
(2008)
Medical Physics
, vol.35
, Issue.3
, pp. 1145-1153
-
-
Murphy, M.J.1
Wei, Z.2
Fatyga, M.3
Williamson, J.4
Anscher, M.5
Wallace, T.6
Weiss, E.7
-
31
-
-
37549061055
-
A simple fixed-point approach to invert deformation field
-
MPHYA6 0094-2405 (),. 10.1118/1.2816107
-
M. Chen, W. L. Q. Chen, and K. J. Ruchala, " A simple fixed-point approach to invert deformation field.," Med. Phys. MPHYA6 0094-2405 35 (1), 81-88 (2008). 10.1118/1.2816107
-
(2008)
Med. Phys.
, vol.35
, Issue.1
, pp. 81-88
-
-
Chen, M.1
Chen, W.L.Q.2
Ruchala, K.J.3
-
32
-
-
77749241845
-
-
personal communication.
-
G. Christensen, personal communication (2009).
-
(2009)
-
-
Christensen, G.1
-
33
-
-
0032153006
-
Image matching as a diffusion process: An analogy with Maxwell's demons
-
MIAECY 1361-8415,. 10.1016/S1361-8415(98)80022-4
-
J. P. Thirion, " Image matching as a diffusion process: An analogy with Maxwell's demons.," Med. Image Anal. MIAECY 1361-8415 2, 243-260 (1998). 10.1016/S1361-8415(98)80022-4
-
(1998)
Med. Image Anal.
, vol.2
, pp. 243-260
-
-
Thirion, J.P.1
-
34
-
-
23944489820
-
Dose reconstruction in deforming lung anatomy: Dose grid size effects and clinical implications
-
DOI 10.1118/1.1949749
-
M. Rosu, " Dose reconstruction in deforming lung anatomy: Dose grid size effects and clinical implications.," Med. Phys. MPHYA6 0094-2405 32, 2487-2495 (2005). 10.1118/1.1949749 (Pubitemid 41197185)
-
(2005)
Medical Physics
, vol.32
, Issue.8
, pp. 2487-2495
-
-
Rosu, M.1
Chetty, I.J.2
Balter, J.M.3
Kessler, M.L.4
McShan, D.L.5
Ten Haken, R.K.6
-
35
-
-
50449084524
-
An energy transfer method for 4D Monte Carlo dose calculation
-
MPHYA6 0094-2405 (),. 10.1118/1.2968215
-
J. V. Siebers and H. Zhong, " An energy transfer method for 4D Monte Carlo dose calculation.," Med. Phys. MPHYA6 0094-2405 35 (9), 4096-4105 (2008). 10.1118/1.2968215
-
(2008)
Med. Phys.
, vol.35
, Issue.9
, pp. 4096-4105
-
-
Siebers, J.V.1
Zhong, H.2
-
36
-
-
35848952290
-
Comparative evaluation of similarity measures for the rigid registration of multi-modal head images
-
DOI 10.1088/0031-9155/52/18/008, PII S0031915507426070
-
D. Škerl, B. L. J. M. Fitzpatrick, and F. Pernuš, " Comparative evaluation of similarity measures for the rigid registration of multi-modal head images.," Phys. Med. Biol. PHMBA7 0031-9155 52, 5587-5601 (2007). 10.1088/0031-9155/52/18/008 (Pubitemid 350056685)
-
(2007)
Physics in Medicine and Biology
, vol.52
, Issue.18
, pp. 5587-5601
-
-
Skerl, D.1
Likar, B.2
Fitzpatrick, J.M.3
Pernus, F.4
-
37
-
-
34547800279
-
FEM-based evaluation of deformable image registration for radiation therapy
-
DOI 10.1088/0031-9155/52/16/001, PII S0031915507471196, 001
-
H. Zhong, T. Peters, and J. V. Siebers, " FEM-based evaluation of deformable image registration for radiation therapy.," Phys. Med. Biol. PHMBA7 0031-9155 52, 4721-4738 (2007). 10.1088/0031-9155/52/16/001 (Pubitemid 47232283)
-
(2007)
Physics in Medicine and Biology
, vol.52
, Issue.16
, pp. 4721-4738
-
-
Zhong, H.1
Peters, T.2
Siebers, J.V.3
-
38
-
-
0035045155
-
Organ/patient geometric variation in external beam radiotherapy and its effects
-
DOI 10.1118/1.1357224
-
D. Yan and D. Lockman, " Organ/patient geometric variation in external beam radiotherapy and its effects.," Med. Phys. MPHYA6 0094-2405 28, 593-602 (2001). 10.1118/1.1357224 (Pubitemid 32323312)
-
(2001)
Medical Physics
, vol.28
, Issue.4
, pp. 593-602
-
-
Yan, D.1
Lockman, D.2
-
39
-
-
77749241844
-
Inclusion of geometric uncertainties in treatment plan evaluation
-
IOBPD3 0360-3016.
-
M. v. Herk, P. Remeijer, and J. V. Lebesque, " Inclusion of geometric uncertainties in treatment plan evaluation.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 44, 665-675 (2002).
-
(2002)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.44
, pp. 665-675
-
-
M, V.H.1
Remeijer, P.2
Lebesque, J.V.3
-
40
-
-
41849104547
-
Assessment of dose reconstruction errors in image-guided radiation therapy
-
PHMBA7 0031-9155 (),. 10.1088/0031-9155/53/3/013
-
H. Zhong, E. Weiss, and J. V. Siebers, " Assessment of dose reconstruction errors in image-guided radiation therapy.," Phys. Med. Biol. PHMBA7 0031-9155 53 (3), 719-736 (2008). 10.1088/0031-9155/53/3/013
-
(2008)
Phys. Med. Biol.
, vol.53
, Issue.3
, pp. 719-736
-
-
Zhong, H.1
Weiss, E.2
Siebers, J.V.3
|