메뉴 건너뛰기




Volumn 22, Issue 5, 2009, Pages 311-314

Optimum post and tooth root diameters for a cast post-core system

Author keywords

[No Author keywords available]

Indexed keywords

BIOMEDICAL AND DENTAL MATERIALS; CHROMIUM DERIVATIVE;

EID: 77749264216     PISSN: 08948275     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (8)

References (25)
  • 1
    • 0026891415 scopus 로고
    • Are endodontically treated teeth more brittle?
    • Sedgley CM, Messer HH. Are endodontically treated teeth more brittle? J Endod 1992;18:332-335.
    • (1992) J Endod , vol.18 , pp. 332-335
    • Sedgley, C.M.1    Messer, H.H.2
  • 2
    • 0018037172 scopus 로고
    • Tooth fracture - A comparison of endodontic and restorative treatments
    • Trabert KC, Caputo AA, Abou-Rass M. Tooth fracture - A comparison of endodontic and restorative treatments. J Endod 1978;4:341-345.
    • (1978) J Endod , vol.4 , pp. 341-345
    • Trabert, K.C.1    Caputo, A.A.2    Abou-Rass, M.3
  • 3
    • 0021464874 scopus 로고
    • Clinically significant factors in dowel design
    • Sorensen JA, Martinoff JT. Clinically significant factors in dowel design. J Prosthet Dent 1984;52:28-35.
    • (1984) J Prosthet Dent , vol.52 , pp. 28-35
    • Sorensen, J.A.1    Martinoff, J.T.2
  • 4
    • 0025423895 scopus 로고
    • Ferrule design and fracture resistance of endodontically-treated teeth
    • Sorensen JA, Engelman MJ. Ferrule design and fracture resistance of endodontically-treated teeth. J Prosthet Dent 1990;63:529-536.
    • (1990) J Prosthet Dent , vol.63 , pp. 529-536
    • Sorensen, J.A.1    Engelman, M.J.2
  • 5
    • 15944364792 scopus 로고    scopus 로고
    • In vitro fracture resistance of endodontically-treated central incisors with varying ferrule heights and configurations
    • Tan PL, Aquilino SA, Gratton DG, Standford CM, Tan SC, Johnson WT, Dawson D. In vitro fracture resistance of endodontically-treated central incisors with varying ferrule heights and configurations J Prosthet Dent 2005;93:331-336.
    • (2005) J Prosthet Dent , vol.93 , pp. 331-336
    • Tan, P.L.1    Aquilino, S.A.2    Gratton, D.G.3    Standford, C.M.4    Tan, S.C.5    Johnson, W.T.6    Dawson, D.7
  • 6
    • 0036358608 scopus 로고    scopus 로고
    • Effect of length and diameter of tapered posts on the retention
    • Nergiz I, Schmage P, Ozcan M, Platzer U. Effect of length and diameter of tapered posts on the retention. J Oral Rehabil 2002;29:28-34.
    • (2002) J Oral Rehabil , vol.29 , pp. 28-34
    • Nergiz, I.1    Schmage, P.2    Ozcan, M.3    Platzer, U.4
  • 7
    • 0027636822 scopus 로고
    • Clinical success of cast metal posts and cores
    • Morgano SM, Milot P. Clinical success of cast metal posts and cores. J Prosthet Dent 1993;70:11-16.
    • (1993) J Prosthet Dent , vol.70 , pp. 11-16
    • Morgano, S.M.1    Milot, P.2
  • 8
    • 0029298713 scopus 로고
    • Survival rate and failure characteristics for two post designs
    • Torbjörner A, Karlsson S, Odman PA. Survival rate and failure characteristics for two post designs. J Prosthet Dent 1995;73:439-444.
    • (1995) J Prosthet Dent , vol.73 , pp. 439-444
    • Torbjörner, A.1    Karlsson, S.2    Odman, P.A.3
  • 9
    • 25844477140 scopus 로고    scopus 로고
    • Finite element analysis of stresses in endodontically treated, dowel-restored teeth
    • Asmussen E, Peutzfeldt A, Sahafi A. Finite element analysis of stresses in endodontically treated, dowel-restored teeth. J Prosthet Dent 2005;94:321-329.
    • (2005) J Prosthet Dent , vol.94 , pp. 321-329
    • Asmussen, E.1    Peutzfeldt, A.2    Sahafi, A.3
  • 10
    • 0030077249 scopus 로고    scopus 로고
    • Influence of post dimension on stress distribution in dentin
    • Holmes DC, Diaz-Arnold AM, Leary JM. Influence of post dimension on stress distribution in dentin. J Prosthet Dent 1996;75:140-147.
    • (1996) J Prosthet Dent , vol.75 , pp. 140-147
    • Holmes, D.C.1    Diaz-Arnold, A.M.2    Leary, J.M.3
  • 12
    • 0030118467 scopus 로고    scopus 로고
    • Restoration of pulpless teeth: Application of traditional principles in present and future context
    • Morgano SM. Restoration of pulpless teeth: Application of traditional principles in present and future context. J Prosthet Dent 1996;75:375-380.
    • (1996) J Prosthet Dent , vol.75 , pp. 375-380
    • Morgano, S.M.1
  • 13
    • 0027354733 scopus 로고
    • The philosophies of dowel diameter preparation: A literature review
    • Lloyd PM, Palik JF. The philosophies of dowel diameter preparation: A literature review. J Prosthet Dent 1993;69:32-36.
    • (1993) J Prosthet Dent , vol.69 , pp. 32-36
    • Lloyd, P.M.1    Palik, J.F.2
  • 14
    • 33847096823 scopus 로고    scopus 로고
    • Effectiveness and dentin bond strengths of two materials for reinforcing thin-walled roots
    • Wu X, Chan ATT, Chen Y-M, Yip KH-K, Smales RJ. Effectiveness and dentin bond strengths of two materials for reinforcing thin-walled roots. Dent Mater 2007;23:479-485.
    • (2007) Dent Mater , vol.23 , pp. 479-485
    • Wu, X.1    Chan, A.T.T.2    Chen, Y.-M.3    Yip, K.H.-K.4    Smales, R.J.5
  • 15
    • 0029351333 scopus 로고
    • Factors to consider for predictable posts and core build-ups of endodontically-treated teeth. Part I: Basic theoretical concepts
    • Manning KE, Yu DC, Yu HC, Kwan EW. Factors to consider for predictable posts and core build-ups of endodontically-treated teeth. Part I: Basic theoretical concepts. J Can Dent Assoc 1995;61:685-695.
    • (1995) J Can Dent Assoc , vol.61 , pp. 685-695
    • Manning, K.E.1    Yu, D.C.2    Yu, H.C.3    Kwan, E.W.4
  • 16
    • 0021513591 scopus 로고
    • The endodontically treated tooth: Restorative concepts and techniques
    • Trabert KC, Cooney JP. The endodontically treated tooth: Restorative concepts and techniques. Dent Clin North Am 1994; 28: 923-951.
    • (1994) Dent Clin North Am , vol.28 , pp. 923-951
    • Trabert, K.C.1    Cooney, J.P.2
  • 17
    • 0032185647 scopus 로고    scopus 로고
    • Retention of parallel-sided titanium posts cemented with six luting agents: An in vitro study
    • Duncan JP, Pameijer, CH. Retention of parallel-sided titanium posts cemented with six luting agents: An in vitro study. J Prosthet Dent 1998; 80:423-428.
    • (1998) J Prosthet Dent , vol.80 , pp. 423-428
    • Duncan, J.P.1    Pameijer, C.H.2
  • 18
    • 0027356917 scopus 로고
    • Effect of post design on resistance to fracture of endodontically treated teeth with complete crowns
    • Assif D, Bitenski A, Pilo R, Oren E. Effect of post design on resistance to fracture of endodontically treated teeth with complete crowns. J Prosthet Dent 1993;69:36-40.
    • (1993) J Prosthet Dent , vol.69 , pp. 36-40
    • Assif, D.1    Bitenski, A.2    Pilo, R.3    Oren, E.4
  • 19
    • 0026218607 scopus 로고
    • Resistance to torsional forces of various post and core designs
    • Hemmings KW, King PA, Setchell DJ. Resistance to torsional forces of various post and core designs. J Prosthet Dent 1991;66:325-329.
    • (1991) J Prosthet Dent , vol.66 , pp. 325-329
    • Hemmings, K.W.1    King, P.A.2    Setchell, D.J.3
  • 20
    • 0029265674 scopus 로고
    • Load fatigue of teeth restored with cast posts and cores and complete crowns
    • Libman WJ, Nicholls JI. Load fatigue of teeth restored with cast posts and cores and complete crowns. Int J Prosthodont 1995;8:155-161.
    • (1995) Int J Prosthodont , vol.8 , pp. 155-161
    • Libman, W.J.1    Nicholls, J.I.2
  • 21
    • 0038166665 scopus 로고    scopus 로고
    • Effects of post-core design and ferrule on fracture resistance of endodontically treated maxillary central incisors
    • Zhi-Yue L, Yu-Xing Z. Effects of post-core design and ferrule on fracture resistance of endodontically treated maxillary central incisors. J Prosthet Dent 2003;89:368-373.
    • (2003) J Prosthet Dent , vol.89 , pp. 368-373
    • Zhi-Yue, L.1    Yu-Xing, Z.2
  • 22
  • 24
    • 36749068864 scopus 로고    scopus 로고
    • Effect of a ferrule and increased clinical crown length on the in vitro fracture resistance of premolars restored using two dowel-and-core systems
    • Meng Q-F, Chen Y-M, Guang H-B, Yip KH-K, Smales RJ. Effect of a ferrule and increased clinical crown length on the in vitro fracture resistance of premolars restored using two dowel-and-core systems. Oper Dent 2007; 32; 595-601.
    • (2007) Oper Dent , vol.32 , pp. 595-601
    • Meng, Q.-F.1    Chen, Y.-M.2    Guang, H.-B.3    Yip, K.H.-K.4    Smales, R.J.5
  • 25
    • 4344632971 scopus 로고    scopus 로고
    • A structural analysis of in vitro failure loads and failure modes of fiber, metal, and ceramic post-and-core systems
    • Fokkinga WA, Kreulen CM, Vallittu PK, Creughers NHJ. A structural analysis of in vitro failure loads and failure modes of fiber, metal, and ceramic post-and-core systems. Int J Prosthodont 2004;17:476-482.
    • (2004) Int J Prosthodont , vol.17 , pp. 476-482
    • Fokkinga, W.A.1    Kreulen, C.M.2    Vallittu, P.K.3    Creughers, N.H.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.