메뉴 건너뛰기




Volumn 2, Issue , 2009, Pages 533-536

Thermal comfort and indoor air quality of task ambient air conditioning in modern office buildings

Author keywords

Fresh air; Indoor air quality; Task ambient air conditioning; Thermal comfort

Indexed keywords

AMBIENT AIR; BENZENE CONCENTRATION; BREATHING ZONES; CLEAN AIR; CLEAN ENVIRONMENT; ENVIRONMENTAL SUSTAINABILITY; FORMING ENERGY; FRESH AIR; GLOBAL TRENDS; INDOOR AIR QUALITY; INDOOR SOURCES; TASK AMBIENT AIR CONDITIONING; VENTILATION EFFICIENCY; VOLUME CONCENTRATION; WORKING ENVIRONMENT;

EID: 77649298039     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICIII.2009.286     Document Type: Conference Paper
Times cited : (12)

References (9)
  • 2
    • 43049138038 scopus 로고    scopus 로고
    • Energy impact assessment for the reduction of carbon dioxide and formaldehyde exposure risk in air-conditioned offices
    • doi:10.1016/j.enbuild.2008.01.002
    • K.W. Mui, L.T. Wong and W.Y. Chan, "Energy impact assessment for the reduction of carbon dioxide and formaldehyde exposure risk in air-conditioned offices," Energy and Buildings, Vol. 40, 2008, pp. 1412-1418. doi:10.1016/j.enbuild.2008.01.002.
    • (2008) Energy and Buildings , vol.40 , pp. 1412-1418
    • Mui, K.W.1    Wong, L.T.2    Chan, W.Y.3
  • 3
    • 77649283302 scopus 로고    scopus 로고
    • http://en.wikipedia.org/wiki/Green-building
  • 4
    • 0012082110 scopus 로고    scopus 로고
    • Task/ambient conditioning systems: Engineering and application guidelines,
    • University of California, Berkeley
    • Bauman F, and Arens E, "Task/ambient conditioning systems: engineering and application guidelines," final report, University of California, Berkeley, 1996.
    • (1996) final report
    • Bauman, F.1    Arens, E.2
  • 6
    • 17044410559 scopus 로고    scopus 로고
    • CFD study on effect of the air supply location on the performance of the displacement ventilation system
    • doi:10.1016/j.buildenv.2004.09.003
    • Z. Lin, T.T. Chow, C.F. Tsang, K.F. Fong and L.S. Chan, "CFD study on effect of the air supply location on the performance of the displacement ventilation system," Building and Environment, Vol. 40, 2005, pp. 1051-1067. doi:10.1016/j.buildenv.2004.09.003.
    • (2005) Building and Environment , vol.40 , pp. 1051-1067
    • Lin, Z.1    Chow, T.T.2    Tsang, C.F.3    Fong, K.F.4    Chan, L.S.5
  • 7
    • 0003814214 scopus 로고
    • Moderate thermal environments-determination of the PMV and PPD indices and specification of the conditions for thermal comfort, ISO
    • ISO 7730, Geneva
    • ISO 7730, "Moderate thermal environments-determination of the PMV and PPD indices and specification of the conditions for thermal comfort," ISO Geneva, 1994.
    • (1994)
  • 8
    • 77649315156 scopus 로고    scopus 로고
    • Numercal simulation on the indoor air quality of displacement ventilation
    • J.W. Cao, "Numercal simulation on the indoor air quality of displacement ventilation," Beijing Jiaotong University, 2006.
    • (2006) Beijing Jiaotong University
    • Cao, J.W.1
  • 9
    • 77649286216 scopus 로고    scopus 로고
    • Design for Acceptable Indoor Air Quality
    • American Society of Heating Refrigerating Air-conditioning Engineers, Atlanta, ANSI/ASHRAE
    • American Society of Heating Refrigerating Air-conditioning Engineers, "Design for Acceptable Indoor Air Quality," American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, 2004(ANSI/ASHRAE 62-2004).
    • (2004) American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc , pp. 62-2004


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.