1
-
-
0023777801
-
Evaluation of a photon and an electron beam of a 6-MV linear accelerator
-
Sharma SC, Modur P, Basavatia R. Evaluation of a photon and an electron beam of a 6-MV linear accelerator. Med Phys. 1988:15(4):525-29.
-
(1988)
Med Phys
, vol.15
, Issue.4
, pp. 525529
-
-
Sharma, S.C.1
Modur, P.2
Basavatia, R.3
-
2
-
-
0025784738
-
Characteristic parameters of 6-21 MeV electron beams from a 21 MeV linear accelerator
-
Al-Ghazi MS, Lingman D, Arjune B, Gilbert LD, Thekkumthala J. Characteristic parameters of 6-21 MeV electron beams from a 21 MeV linear accelerator. Med Phys. 1991;18(4):821-28
-
(1991)
Med Phys
, vol.18
, Issue.4
, pp. 821-828
-
-
Al-Ghazi, M.S.1
Lingman, D.2
Arjune, B.3
Gilbert, L.D.4
Thekkumthala, J.5
-
3
-
-
0033431859
-
Comparative measurements on a series of accelerators by the same vendor
-
Watts RJ. Comparative measurements on a series of accelerators by the same vendor. Med Phys. 1999;26(12):2581-85.
-
(1999)
Med Phys
, vol.26
, Issue.12
, pp. 2581-2585
-
-
Watts, R.J.1
-
4
-
-
0035989939
-
Comparison of characteristics of photon and electron beams generated by Philips/Elekta and Varian linear accelerators
-
Song H, Xiao Y, Galvin JM. Comparison of characteristics of photon and electron beams generated by Philips/Elekta and Varian linear accelerators. Med Phys. 2002;29(6):960-66.
-
(2002)
Med Phys
, vol.29
, Issue.6
, pp. 960-966
-
-
Song, H.1
Xiao, Y.2
Galvin, J.M.3
-
5
-
-
2942553910
-
Comparison of electron beam characteristics from multiple accelerators
-
Followill DS, Davis DS, Ibbott GS. Comparison of electron beam characteristics from multiple accelerators. Int J Radiat Oncol Biol Phys. 2004;59(3):905-10.
-
(2004)
Int J Radiat Oncol Biol Phys
, vol.59
, Issue.3
, pp. 905-910
-
-
Followill, D.S.1
Davis, D.S.2
Ibbott, G.S.3
-
6
-
-
60549099223
-
A beam-matching concept for medical linear accelerators
-
Sjöström D, Bjelkengren U, Ottosson W, Behrens CF. A beam-matching concept for medical linear accelerators. Acta Oncol. 2009;48(2):1-9.
-
(2009)
Acta Oncol
, vol.48
, Issue.2
, pp. 1-9
-
-
Sjöström, D.1
Bjelkengren, U.2
Ottosson, W.3
Behrens, C.F.4
-
7
-
-
0032874911
-
AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams
-
Almond PR, Biggs PJ, Coursey BM, et al. AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams. Med Phys. 1999;26(9):1847-70.
-
(1999)
Med Phys
, vol.26
, Issue.9
, pp. 1847-1870
-
-
Almond, P.R.1
Biggs, P.J.2
Coursey, B.M.3
-
8
-
-
0025975407
-
Clinical electron-beam dosimetry: report of AAPM Radiation Therapy Committee Task Group No 25
-
Khan FM, Doppke KP, Hogstrom KR, et al. Clinical electron-beam dosimetry: report of AAPM Radiation Therapy Committee Task Group No. 25. Med Phys. 1991;18(1):73-109.
-
(1991)
Med Phys
, vol.18
, Issue.1
, pp. 73-109
-
-
Khan, F.M.1
Doppke, K.P.2
Hogstrom, K.R.3
-
9
-
-
50449083499
-
Accelerator beam data commissioning equipment and procedures: report of the TG-106 of the Therapy Physics Committee of the AAPM
-
Das IJ, Cheng CW, Watts RJ, et al. Accelerator beam data commissioning equipment and procedures: report of the TG-106 of the Therapy Physics Committee of the AAPM. Med Phys. 2008;35(9):4186-215.
-
(2008)
Med Phys
, vol.35
, Issue.9
, pp. 4186-4215
-
-
Das, I.J.1
Cheng, C.W.2
Watts, R.J.3
-
10
-
-
85024388088
-
Particular requirements for the safety of electron accelerators in the range 1 MeV to 50 MeV
-
International Electrotechnical Commission. IEC 60601-2-1, Clause 29.3.1.2. Available from
-
International Electrotechnical Commission. Particular requirements for the safety of electron accelerators in the range 1 MeV to 50 MeV, IEC 60601-2-1, Clause 29.3.1.2. 2002. Available from: www.iec.ch/searchpub/
-
(2002)
-
-
|