메뉴 건너뛰기




Volumn 5, Issue 2, 2010, Pages 163-171

An automated insertion tool for cochlear implants: Another step towards atraumatic cochlear implant surgery

Author keywords

Atraumatic electrode insertion; Automated insertion tool; Cochlear implant; Minimally invasive surgery

Indexed keywords

ARTICLE; AUTOMATION; COCHLEA PROSTHESIS; CONTROLLED STUDY; EARDRUM; ELECTRODE; EQUIPMENT DESIGN; FLUOROSCOPY; HUMAN; HUMAN TISSUE; IMPLANTATION; MATHEMATICAL ANALYSIS; MINIMALLY INVASIVE SURGERY; PRIORITY JOURNAL; SURGICAL APPROACH; SURGICAL EQUIPMENT; SURGICAL TECHNOLOGY; X RAY;

EID: 77649238375     PISSN: 18616410     EISSN: 18616429     Source Type: Journal    
DOI: 10.1007/s11548-009-0368-0     Document Type: Article
Times cited : (50)

References (29)
  • 1
    • 62349092532 scopus 로고    scopus 로고
    • Implant design and development
    • Cooper H, Craddock L, Cochlear implants 2nd ed
    • Grayden DB, Clark GM (2006) Implant design and development. In: Cooper H, Craddock L, Cochlear implants: a practical guide, 2nd ed, pp 1-20
    • (2006) A Practical Guide , pp. 1-20
    • Grayden, D.B.1    Clark, G.M.2
  • 4
  • 6
    • 8844232696 scopus 로고    scopus 로고
    • Navigation as a quality management tool in cochlear implant surgery
    • Oct 2004. [Online]. Available
    • Schipper J, Aschendorff A, Arapakis I, Klenzner T, Teszler CB, Ridder GJ, Laszig R (2004) Navigation as a quality management tool in cochlear implant surgery. J Laryngol Otol, 118(10): 764-770, Oct 2004. [Online]. Available: http://dx.doi.org/10.1258/0022215042450643
    • (2004) J Laryngol Otol , vol.118 , Issue.10 , pp. 764-770
    • Schipper, J.1    Aschendorff, A.2    Arapakis, I.3    Klenzner, T.4    Teszler, C.B.5    Ridder, G.J.6    Laszig, R.7
  • 7
    • 24044532572 scopus 로고    scopus 로고
    • Cochleostomy site: Implications for electrode placement and hearing preservation
    • DOI 10.1080/00016480510031489
    • R Briggs M Tykocinski K Stidham J Roberson 2005 Cochleostomy site: implications for electrode placement and hearing preservation Acta Otolaryngol 125 8 870 876 10.1080/00016480510031489 10.1080/00016480510031489 16158535 (Pubitemid 41224108)
    • (2005) Acta Oto-Laryngologica , vol.125 , Issue.8 , pp. 870-876
    • Briggs, R.J.S.1    Tykocinski, M.2    Stidham, K.3    Roberson, J.B.4
  • 8
    • 34547567034 scopus 로고    scopus 로고
    • ENT challenges at the small scale
    • [Online]. Available
    • Coulson CJ, Reid AP, Proops DW, Brett PN (2007) ENT challenges at the small scale. Int J Med Robot, 3(2), 91-96, [Online]. Available: http://dx.doi.org/10.1002/rcs.132
    • (2007) Int J Med Robot , vol.3 , Issue.2 , pp. 91-96
    • Coulson, C.J.1    Reid, A.P.2    Proops, D.W.3    Brett, P.N.4
  • 15
    • 34247198964 scopus 로고    scopus 로고
    • Percutaneous cochlear access using bone-mounted, customized drill guides: Demonstration of concept in vitro
    • DOI 10.1097/01.mao.0000253287.86737.2e, PII 0012949220070400000006
    • FM Warren R Balachandran JM Fitzpatrick RF Labadie 2007 Percutaneous cochlear access using bone-mounted, customized drill guides: Demonstration of concept in vitro Otol Neurotol 28 3 325 329 10.1097/01.mao.0000253287.86737.2e 10.1097/01.mao.0000253287.86737.2e 17414037 (Pubitemid 46607902)
    • (2007) Otology and Neurotology , vol.28 , Issue.3 , pp. 325-329
    • Warren, F.M.1    Balachandran, R.2    Fitzpatrick, J.M.3    Labadie, R.F.4
  • 17
    • 49749093369 scopus 로고    scopus 로고
    • An autonomous surgical robot for drilling a cochleostomy: Preliminary porcine trial
    • [Online]. Available
    • Coulson CJ, Taylor RP, Reid AP, Griffiths MV, Proops DW, Brett PN (2008) An autonomous surgical robot for drilling a cochleostomy: preliminary porcine trial. Clin Otolaryngol 33(4):343-347, [Online]. Available: http://dx.doi.org/ 10.1111/j.1749-4486.2008.01703.x
    • (2008) Clin Otolaryngol , vol.33 , Issue.4 , pp. 343-347
    • Coulson, C.J.1    Taylor, R.P.2    Reid, A.P.3    Griffiths, M.V.4    Proops, D.W.5    Brett, P.N.6
  • 20
    • 33750333181 scopus 로고    scopus 로고
    • The size of the cochlea and predictions of insertion depth angles for cochlear implant electrodes
    • (Suppl 1) [Online]. Available
    • Escudé B, James C, Deguine O, Cochard N, Eter E, Fraysse B (2006) The size of the cochlea and predictions of insertion depth angles for cochlear implant electrodes. Audiol Neurootol 11(Suppl 1):27-33, [Online]. Available: http://dx.doi.org/10.1159/000095611
    • (2006) Audiol Neurootol , vol.11 , pp. 27-33
    • Escudé, B.1    James, C.2    Deguine, O.3    Cochard, N.4    Eter, E.5    Fraysse, B.6
  • 21
    • 0033985953 scopus 로고    scopus 로고
    • Cochlear view: Postoperative radiography for cochlear implantation
    • 1:STN:280:DC%2BD3c7hsVymtQ%3D%3D 10651435
    • J Xu SA Xu LT Cohen GM Clark 2000 Cochlear view: postoperative radiography for cochlear implantation Am J Otol 21 1 49 56 1:STN:280: DC%2BD3c7hsVymtQ%3D%3D 10651435
    • (2000) Am J Otol , vol.21 , Issue.1 , pp. 49-56
    • Xu, J.1    Xu, S.A.2    Cohen, L.T.3    Clark, G.M.4
  • 22
    • 0032215286 scopus 로고    scopus 로고
    • In vivo measures of cochlear length and insertion depth of nucleus cochlear implant electrode arrays
    • 1:STN:280:DyaK1M%2FksVWkug%3D%3D
    • DR Ketten MW Skinner G Wang MW Vannier GA Gates JG Neely 1998 In vivo measures of cochlear length and insertion depth of nucleus cochlear implant electrode arrays Ann Otol Rhinol Laryngol 175 Suppl 1 16 1:STN:280: DyaK1M%2FksVWkug%3D%3D
    • (1998) Ann Otol Rhinol Laryngol , vol.175 , Issue.SUPPL , pp. 1-16
    • Ketten, D.R.1    Skinner, M.W.2    Wang, G.3    Vannier, M.W.4    Gates, G.A.5    Neely, J.G.6
  • 23
    • 0034306047 scopus 로고    scopus 로고
    • Three-dimensional geometric modeling of the cochlea using helico-spiral approximation
    • DOI 10.1109/10.871413, PII S0018929400085293
    • S Yoo G Wang J Rubinstein M Vannier 2000 Three-dimensional geometric modeling of the cochlea using helico-spiral approximation Biomed Eng IEEE Trans 47 10 1392 1402 10.1109/10.871413 10.1109/10.871413 1:STN:280: DC%2BD3crgvVCktg%3D%3D (Pubitemid 30770404)
    • (2000) IEEE Transactions on Biomedical Engineering , vol.47 , Issue.10 , pp. 1392-1402
    • Yoo, S.K.1    Wang, G.2    Rubinstein, J.T.3    Vannier, M.W.4
  • 24
    • 34547797971 scopus 로고    scopus 로고
    • 3d finite element analyses of insertion of the nucleus standard straight and the contour electrode arrays into the human cochlea
    • [Online]. Available
    • Kha HN, Chen BK, Clark GM (2007) 3d finite element analyses of insertion of the nucleus standard straight and the contour electrode arrays into the human cochlea. J Biomech 40(12):2796-2805. [Online]. Available: http://dx.doi.org/10. 1016/j.jbiomech.2007.01.013
    • (2007) J Biomech , vol.40 , Issue.12 , pp. 2796-2805
    • Kha, H.N.1    Chen, B.K.2    Clark, G.M.3
  • 26
    • 77649236508 scopus 로고    scopus 로고
    • Surgeon's Guide for the C124R (CA) cochlear implant, Cochlear Ltd., Lane Cove, NSW, Australia
    • Surgeon's Guide for the C124R (CA) cochlear implant, Cochlear Ltd., Lane Cove, NSW, Australia.
  • 27
    • 28144448338 scopus 로고    scopus 로고
    • Evaluation of the Advance Off-Stylet insertion technique and the cochlear insertion tool in temporal bones
    • DOI 10.1097/01.mao.0000179527.17285.85
    • T Stover P Issing G Graurock P Erfurt Y ElBeltagy G Paasche T Lenarz 2005 Evaluation of the advance off-stylet insertion technique and the cochlear insertion tool in temporal bones Otol Neurotol 26 6 1161 1170 10.1097/01.mao.0000179527.17285.85 10.1097/01.mao.0000179527.17285.85 16272935 (Pubitemid 41697371)
    • (2005) Otology and Neurotology , vol.26 , Issue.6 , pp. 1161-1170
    • Stover, T.1    Issing, P.2    Graurock, G.3    Erfurt, P.4    ElBeltagy, Y.5    Paasche, G.6    Lenarz, T.7
  • 28
    • 0141752840 scopus 로고    scopus 로고
    • Combining acoustic and electrical hearing
    • DOI 10.1097/00005537-200310000-00012
    • B Gantz CW Turner 2003 Combining acoustic and electrical hearing Laryngoscope 113 10 1726 1730 10.1097/00005537-200310000-00012 10.1097/00005537-200310000-00012 14520097 (Pubitemid 37210974)
    • (2003) Laryngoscope , vol.113 , Issue.10 , pp. 1726-1730
    • Gantz, B.J.1    Turner, C.W.2
  • 29
    • 2942739438 scopus 로고    scopus 로고
    • Hearing preservation in cochlear implantation for electric acoustic stimulation
    • DOI 10.1080/00016480410016432
    • W Gstoettner J Kiefer WD Baumgartner S Pok S Peters O Adunka 2004 Hearing preservation in cochlear implantation for electric acoustic stimulation Acta Otolaryngol 124 4 348 352 10.1080/00016480410016432 10.1080/00016480410016432 15224851 (Pubitemid 38797582)
    • (2004) Acta Oto-Laryngologica , vol.124 , Issue.4 , pp. 348-352
    • Gstoettner, W.1    Kiefer, J.2    Baumgartner, W.-D.3    Pok, S.4    Peters, S.5    Adunka, O.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.