메뉴 건너뛰기




Volumn 31, Issue 1, 2010, Pages 39-55

Robust MPC for temperature control of air-conditioning systems concerning on constraints and multitype uncertainties

Author keywords

[No Author keywords available]

Indexed keywords

AIRCONDITIONING SYSTEMS; CONSTANT AIR VOLUMES; CONTROL DESIGN; CONTROL OBJECTIVES; DISCRETE MODELS; DYNAMIC SIMULATION; DYNAMICS UNCERTAINTIES; HVAC SYSTEM; ONLINE TUNING; OPERATING ENVIRONMENT; PID CONTROL; POLYTOPES; RATE LIMIT; ROBUST CONTROLLERS; ROBUST MODEL PREDICTIVE CONTROL; ROBUST MODELS; SAMPLING PERIOD; SIMULATION TESTS; STATE-SPACE;

EID: 77649219633     PISSN: 01436244     EISSN: 14770849     Source Type: Journal    
DOI: 10.1177/0143624409352420     Document Type: Article
Times cited : (36)

References (24)
  • 3
    • 13644279246 scopus 로고    scopus 로고
    • A fuzzy decision-making approach to temperature control in air-conditioning systems
    • Thompson R., Dexter AL A fuzzy decision-making approach to temperature control in air-conditioning systems. Control Engineering Practice 2005 ; 13 (6). 689-698.
    • (2005) Control Engineering Practice , vol.13 , Issue.6 , pp. 689-698
    • Thompson, R.1    Dexter, A.L.2
  • 4
    • 0032118019 scopus 로고    scopus 로고
    • A temperature controller for VAV air-handling units based on simplified physical models
    • Salsbury TI A temperature controller for VAV air-handling units based on simplified physical models. HVAC&R Research 1998 ; 4 (3). 265-279.
    • (1998) HVAC&R Research , vol.4 , Issue.3 , pp. 265-279
    • Salsbury, T.I.1
  • 13
    • 0029772815 scopus 로고    scopus 로고
    • Long-range predictive control using fuzzy process models
    • Linkens DA, Kandiah S. Long-range predictive control using fuzzy process models. Transactions of IChemE 1996 ; 74 (Part A): 77-88.
    • (1996) Transactions of IChemE , vol.74 , pp. 77-88
    • Linkens, D.A.1    Kandiah, S.2
  • 14
    • 49249112400 scopus 로고    scopus 로고
    • Two-loop robust model predictive control for the temperature control of air-handling units
    • Huang G., Wang SW Two-loop robust model predictive control for the temperature control of air-handling units. HVAC&R Research 2008 ; 14 (4). 565-580.
    • (2008) HVAC&R Research , vol.14 , Issue.4 , pp. 565-580
    • Huang, G.1    Wang, S.W.2
  • 15
    • 67651205236 scopus 로고    scopus 로고
    • A robust model predictive control strategy for improving the control performance of air conditioning systems
    • Huang G., Wang SW, Xu XH A robust model predictive control strategy for improving the control performance of air conditioning systems. Energy Conversion and Management 2009 ; 50 (10). 2650-2658.
    • (2009) Energy Conversion and Management , vol.50 , Issue.10 , pp. 2650-2658
    • Huang, G.1    Wang, S.W.2    Xu, X.H.3
  • 16
    • 0037401745 scopus 로고    scopus 로고
    • An efficient off-line formulation of robust model predictive control using linear matrix inequalities
    • Wan Z., Kothare MV An efficient off-line formulation of robust model predictive control using linear matrix inequalities. Automatica 2003 ; 39 (5). 837-846.
    • (2003) Automatica , vol.39 , Issue.5 , pp. 837-846
    • Wan, Z.1    Kothare, M.V.2
  • 19
    • 77649215130 scopus 로고    scopus 로고
    • Trnsys. University of Wisconsin, USA, Solar Energy Laboratory, Version
    • Trnsys. A transient simulation program: documentation. University of Wisconsin, USA, Solar Energy Laboratory, Version 16, 2004.
    • (2004) A Transient Simulation Program: Documentation , pp. 16
  • 20
    • 0032643161 scopus 로고    scopus 로고
    • Dynamic simulation of building VAV air-conditioning system and evaluation of EMCS on-line control strategies
    • Wang SW Dynamic simulation of building VAV air-conditioning system and evaluation of EMCS on-line control strategies. Building and Environment 1999 ; 34 (6). 681-705.
    • (1999) Building and Environment , vol.34 , Issue.6 , pp. 681-705
    • Wang, S.W.1
  • 22
    • 0041136242 scopus 로고    scopus 로고
    • Cooling coil models to be used in transient and/or wet regimes-theoretical analysis and experimental validation
    • Lebrun J., Ding X., Eppe JP, Wasacz T. Cooling coil models to be used in transient and/or wet regimes-theoretical analysis and experimental validation: Proceedings of System Simulation in Building'90. Liege, Belgium, 1990.
    • Proceedings of System Simulation in Building'90
    • Lebrun, J.1    Ding, X.2    Eppe, J.P.3    Wasacz, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.