메뉴 건너뛰기




Volumn 96, Issue 5, 2010, Pages 390-397

Three dimensional echocardiography: Approaches and clinical utility

Author keywords

[No Author keywords available]

Indexed keywords

AORTA VALVE; ARTICLE; HEART ATRIUM; HEART LEFT VENTRICLE FUNCTION; HEART LEFT VENTRICLE MASS; HEART LEFT VENTRICLE VOLUME; HEART RIGHT VENTRICLE VOLUME; HUMAN; MITRAL VALVE; MITRAL VALVE REGURGITATION; MITRAL VALVE STENOSIS; PRIORITY JOURNAL; THREE DIMENSIONAL ECHOCARDIOGRAPHY; THREE DIMENSIONAL IMAGING; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; VALVULAR HEART DISEASE;

EID: 77649212972     PISSN: 13556037     EISSN: 1468201X     Source Type: Journal    
DOI: 10.1136/hrt.2007.132803     Document Type: Article
Times cited : (32)

References (17)
  • 1
    • 33847251987 scopus 로고    scopus 로고
    • Hung J, Lang R, Flachskampf F, et al. 3D Echocardiography: a review of the current status and future directions. J Am Soc Echocardiogr 2007;20:213-33. ▶ From the American Society of Echocardiography, a comprehensive review of 3D echocardiography imaging techniques and clinical applications.
    • Hung J, Lang R, Flachskampf F, et al. 3D Echocardiography: a review of the current status and future directions. J Am Soc Echocardiogr 2007;20:213-33. ▶ From the American Society of Echocardiography, a comprehensive review of 3D echocardiography imaging techniques and clinical applications.
  • 2
    • 33646691308 scopus 로고    scopus 로고
    • Comparison of orifice area by transthoracic three-dimensional Doppler echocardiography versus proximal isovelocity surface area (PISA) method for assessment of mitral regurgitation
    • Iwakura K, Ito H, Kawano S, et al. Comparison of orifice area by transthoracic three-dimensional Doppler echocardiography versus proximal isovelocity surface area (PISA) method for assessment of mitral regurgitation. Am J Cardiol 2006;97:1630-7.
    • (2006) Am J Cardiol , vol.97 , pp. 1630-1637
    • Iwakura, K.1    Ito, H.2    Kawano, S.3
  • 3
    • 0028877208 scopus 로고
    • Three-dimensional echocardiography improves noninvasive assessment of left ventricular volume and performance
    • One of the original studies demonstrating the accuracy of left ventricular determination by 3D echocardiography, ▶
    • Siu SC, Levine RA, Rivera JM, et al. Three-dimensional echocardiography improves noninvasive assessment of left ventricular volume and performance. Am Heart J 1995;130:812-22. ▶ One of the original studies demonstrating the accuracy of left ventricular volume determination by 3D echocardiography.
    • (1995) Am Heart J , vol.130 , pp. 812-822
    • Siu, S.C.1    Levine, R.A.2    Rivera, J.M.3
  • 4
    • 33747431187 scopus 로고    scopus 로고
    • Sugeng L, Mor-Avi V, Weinert L, et al. Quantitative assessment of left ventricular size and function: side-by-side comparison of real-time three-dimensional echocardiography and computed tomography with magnetic resonance reference. Circulation 2006;114:654-61. ▶ Validation study of real-time 3D echocardiographic quantification of LV
    • Sugeng L, Mor-Avi V, Weinert L, et al. Quantitative assessment of left ventricular size and function: side-by-side comparison of real-time three-dimensional echocardiography and computed tomography with magnetic resonance reference. Circulation 2006;114:654-61. ▶ Validation study of real-time 3D echocardiographic quantification of LV volume.
  • 5
    • 58149171451 scopus 로고    scopus 로고
    • Left ventricular volume measurement with echocardiography: A comparison of left ventricular opacification, three-dimensional echocardiography, or both with magnetic resonance imaging
    • Jenkins C, Moir S, Chan J, et al. Left ventricular volume measurement with echocardiography: a comparison of left ventricular opacification, three-dimensional echocardiography, or both with magnetic resonance imaging. Eur Heart J 2009;30:98-106.
    • (2009) Eur Heart J , vol.30 , pp. 98-106
    • Jenkins, C.1    Moir, S.2    Chan, J.3
  • 6
    • 47349116645 scopus 로고    scopus 로고
    • Mor-Avi V, Jenkins C, Kuhl HP, et al. Real-time 3-dimensional echocardiographic quantification of left ventricular multicenter study of validation with magnetic resonance imaging and investigation of sources of error. JACC Cardiovasc Imaging 2008;1:413-23. ▶ A multicentre study demonstrating the reliability of 3D echocardiographic derived LV and their high correlation with cMR. This paper explores some of the reasons that 3D echocardiography can underestimate LV when compared to cMR.
    • Mor-Avi V, Jenkins C, Kuhl HP, et al. Real-time 3-dimensional echocardiographic quantification of left ventricular volumes: multicenter study of validation with magnetic resonance imaging and investigation of sources of error. JACC Cardiovasc Imaging 2008;1:413-23. ▶ A multicentre study demonstrating the reliability of 3D echocardiographic derived LV volumes and their high correlation with cMR. This paper explores some of the reasons that 3D echocardiography can underestimate LV volume when compared to cMR.
  • 7
    • 0008353117 scopus 로고    scopus 로고
    • Real-time, three dimensional echocardiography: Feasibility of dynamic right ventricular volume measurement with saline contrast
    • Ota T, Fleishman CE, Strub M, et al. Real-time, three dimensional echocardiography: feasibility of dynamic right ventricular volume measurement with saline contrast. Am Heart J 1999;137:958-66.
    • (1999) Am Heart J , vol.137 , pp. 958-966
    • Ota, T.1    Fleishman, C.E.2    Strub, M.3
  • 8
    • 64649092670 scopus 로고    scopus 로고
    • Left atrial volume measurement with automated border detection by 3-dimensional echocardiography: Comparison with magnetic resonance imaging
    • Artang R, Migrino RQ, Harmann L, et al. Left atrial volume measurement with automated border detection by 3-dimensional echocardiography: comparison with magnetic resonance imaging. Cardiovasc Ultrasound 2009;7:16.
    • (2009) Cardiovasc Ultrasound , vol.7 , pp. 16
    • Artang, R.1    Migrino, R.Q.2    Harmann, L.3
  • 9
    • 24344471725 scopus 로고    scopus 로고
    • Jenkins C, Bricknell K, Marwick TH. Use of real-time three-dimensional echocardiography to measure left atrial comparison with other echocardiographic techniques. J Am Soc Echocardiogr 2005;18:991-7. ▶ Study showing the value of 3D echocardiography for serial assessment of cardiac structure and function. Compared to 2D echocardiographic methods, reduced test-retest variation with 3D echocardiographic measurement of LV EF, and mass measurements is demonstrated.
    • Jenkins C, Bricknell K, Marwick TH. Use of real-time three-dimensional echocardiography to measure left atrial volume: comparison with other echocardiographic techniques. J Am Soc Echocardiogr 2005;18:991-7. ▶ Study showing the value of 3D echocardiography for serial assessment of cardiac structure and function. Compared to 2D echocardiographic methods, reduced test-retest variation with 3D echocardiographic measurement of LV volume, EF, and mass measurements is demonstrated.
  • 10
    • 50249146343 scopus 로고    scopus 로고
    • Measurement of left ventricular mass by real-time three-dimensional echocardiography: Validation against magnetic resonance and comparison with two-dimensional and M-mode measurements
    • Takeuchi M, Nishikage T, Mor-Avi V, et al. Measurement of left ventricular mass by real-time three-dimensional echocardiography: validation against magnetic resonance and comparison with two-dimensional and M-mode measurements. J Am Soc Echocardiogr 2008;21:1001-5.
    • (2008) J Am Soc Echocardiogr , vol.21 , pp. 1001-1005
    • Takeuchi, M.1    Nishikage, T.2    Mor-Avi, V.3
  • 11
    • 2542447998 scopus 로고    scopus 로고
    • Zamorano J, Cordeiro P, Sugeng L, et al. Real-time three-dimensional echocardiography for rheumatic mitral valve stenosis evaluation: an accurate and novel approach. J Am Coll Cardiol 2004;43:2091-6. ▶ Early report of the accuracy of real-time 3D transthoracic echocardiography for the quantitation of mitral valve area in mitral stenosis.
    • Zamorano J, Cordeiro P, Sugeng L, et al. Real-time three-dimensional echocardiography for rheumatic mitral valve stenosis evaluation: an accurate and novel approach. J Am Coll Cardiol 2004;43:2091-6. ▶ Early report of the accuracy of real-time 3D transthoracic echocardiography for the quantitation of mitral valve area in mitral stenosis.
  • 12
    • 26244463956 scopus 로고    scopus 로고
    • Usefulness of three-dimensionally guided assessment of mitral stenosis using matrix-array ultrasound
    • Demonstration of the feasibility and reproducibility of 3D guided measurement of the mitral orifice area in mitral stenosis, ▶
    • Sebag IA, Morgan JG, Handschumacher MD, et al. Usefulness of three-dimensionally guided assessment of mitral stenosis using matrix-array ultrasound. Am J Cardiol. 2005;96:1151-6. ▶Demonstration of the feasibility and reproducibility of 3D guided measurement of the mitral orifice area in mitral stenosis.
    • (2005) Am J Cardiol , vol.96 , pp. 1151-1156
    • Sebag, I.A.1    Morgan, J.G.2    Handschumacher, M.D.3
  • 13
    • 33845290234 scopus 로고    scopus 로고
    • Pepi M, Tamborini G, Maltagliati A, et al. Head-to-head comparison of two- and three-dimensional transthoracic and transesophageal echocardiography in the localization of mitral valve prolapse. J Am Coll Cardiol 2006;48:2524-30. ▶ Nicely illustrated study demonstrating that the precise location of mitral valve prolapse defects can be visualised better on real-time 3D transthoracic echo and 3D transoesophageal echo (by reconstruction technique) compared to 2D methods.
    • Pepi M, Tamborini G, Maltagliati A, et al. Head-to-head comparison of two- and three-dimensional transthoracic and transesophageal echocardiography in the localization of mitral valve prolapse. J Am Coll Cardiol 2006;48:2524-30. ▶ Nicely illustrated study demonstrating that the precise location of mitral valve prolapse defects can be visualised better on real-time 3D transthoracic echo and 3D transoesophageal echo (by reconstruction technique) compared to 2D methods.
  • 14
    • 0035131230 scopus 로고    scopus 로고
    • Mechanism of ischemic mitral regurgitation with segmental left ventricular dysfunction: Three-dimensional echocardiographic studies in models of acute and chronic progressive regurgitation
    • Otsuji Y, Handschumacher MD, Liel-Cohen N, et al. Mechanism of ischemic mitral regurgitation with segmental left ventricular dysfunction: three-dimensional echocardiographic studies in models of acute and chronic progressive regurgitation. J Am Coll Cardiol 2001;37:641-8.
    • (2001) J Am Coll Cardiol , vol.37 , pp. 641-648
    • Otsuji, Y.1    Handschumacher, M.D.2    Liel-Cohen, N.3
  • 15
    • 0028432448 scopus 로고
    • Ultrasonic dynamic three-dimensional visualization of the heart with a multiplane transesophageal imaging transducer
    • Roelandt JR, ten Cate FJ, Vletter WB, et al. Ultrasonic dynamic three-dimensional visualization of the heart with a multiplane transesophageal imaging transducer. J Am Soc Echocardiogr 1994;7:217-29.
    • (1994) J Am Soc Echocardiogr , vol.7 , pp. 217-229
    • Roelandt, J.R.1    ten Cate, F.J.2    Vletter, W.B.3
  • 16
    • 56549128656 scopus 로고    scopus 로고
    • Real-time three-dimensional transesophageal echocardiography in valve disease: Comparison with surgical findings and evaluation of prosthetic valves
    • Study highlighting the feasibility and accuracy of 3D transoesophageal echocardiography to image and assess the morphology of native and prosthetic heart valves, ▶
    • Sugeng L, Shernan SK, Weinert L, et al. Real-time three-dimensional transesophageal echocardiography in valve disease: comparison with surgical findings and evaluation of prosthetic valves. J Am Soc Echocardiogr 2008;21:1347-54. ▶ Study highlighting the feasibility and accuracy of 3D transoesophageal echocardiography to image and assess the morphology of native and prosthetic heart valves.
    • (2008) J Am Soc Echocardiogr , vol.21 , pp. 1347-1354
    • Sugeng, L.1    Shernan, S.K.2    Weinert, L.3
  • 17
    • 56249135051 scopus 로고    scopus 로고
    • Initial experience with real-time three-dimensional transesophageal echocardiography in patients undergoing transcatheter atrial septal defect closure
    • Passeri JJ, Inglessis I, Palacios IF, et al. Initial experience with real-time three-dimensional transesophageal echocardiography in patients undergoing transcatheter atrial septal defect closure. Circulation 2007;116:II-401.
    • (2007) Circulation , vol.116 , Issue.II-401
    • Passeri, J.J.1    Inglessis, I.2    Palacios, I.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.