메뉴 건너뛰기




Volumn 9, Issue SPEC. ISS. A, 2009, Pages

Lung cancer screening update

Author keywords

Lung cancer; Mass screening; Screening; Tomography; X ray computed

Indexed keywords

ADULT; AGED; COMPUTER ASSISTED TOMOGRAPHY; FOLLOW UP; HUMAN; INCIDENCE; LUNG DISEASE; LUNG NODULE; LUNG TUMOR; MASS SCREENING; METHODOLOGY; MIDDLE AGED; POSITRON EMISSION TOMOGRAPHY; RADIOGRAPHY; REVIEW; RISK; SCINTISCANNING; SENSITIVITY AND SPECIFICITY; SMOKING; STATISTICS; SURVIVAL; UTILIZATION REVIEW;

EID: 77649201589     PISSN: None     EISSN: 14707330     Source Type: Journal    
DOI: 10.1102/1470-7330.2009.9045     Document Type: Article
Times cited : (4)

References (30)
  • 1
    • 0034551651 scopus 로고    scopus 로고
    • Primary prevention, smoking, and smoking cessation: Implications for future trends in lung cancer prevention
    • doi:10.1002/1097-0142(20001201)89:11+-52506::AID-CNCR3343.3. CO+ADs-2-+ACM-. PMid:11147637.
    • Burns DM. Primary prevention, smoking, and smoking cessation: implications for future trends in lung cancer prevention. Cancer 2000+ADs-89: 2506-9. doi:10.1002/1097-0142(20001201)89:11+-52506::AID-CNCR3343.3.CO+ADs-2- +ACM-. PMid:11147637.
    • (2000) Cancer , vol.89 , pp. 2506-2506
    • Burns, D.M.1
  • 2
    • 0026573360 scopus 로고
    • The effect of surgical treatment on survival from early lung cancer
    • doi:10.1378/ chest.101.4.1013. PMid:1313349.
    • Flehinger BJ, Kimmel M, Melamed MR. The effect of surgical treatment on survival from early lung cancer. Implications for screening. Chest 1992+ADs-101: 1013-18. doi:10.1378/ chest.101.4.1013. PMid:1313349.
    • (1992) Implications for Screening. Chest , vol.101 , pp. 1013-1013
    • Flehinger, B.J.1    Kimmel, M.2    Melamed, M.R.3
  • 3
    • 24944438229 scopus 로고    scopus 로고
    • Limitations of screening for lung cancer with low dose spiral computed tomography
    • doi:10.1158/1078-0432.CCR-05-9000. PMid:16000601.
    • Jett JR. Limitations of screening for lung cancer with low dose spiral computed tomography. Clin Cancer Res 2005+ADs-11: 4988s-92s. doi:10.1158/1078-0432.CCR-05-9000. PMid:16000601.
    • (2005) Clin Cancer Res , vol.11
    • Jett, J.R.1
  • 4
    • 0033542870 scopus 로고    scopus 로고
    • Early Lung Cancer Action Project: Overall design and findings from baseline screening
    • doi:10.1016/S0140-6736(99)06093-6.
    • Henschke CI, McCauley DI, Yankelevitz DF, et al. Early Lung Cancer Action Project: overall design and findings from baseline screening. Lancet 1999+ADs-354: 99-105. doi:10.1016/S0140-6736(99)06093-6.
    • (1999) Lancet , vol.354 , pp. 99-99
    • Henschke, D.F.1
  • 5
    • 0032565365 scopus 로고    scopus 로고
    • Mass screening for lung cancer with mobile spiral computed tomography scanner
    • doi:10.1016/S0140-6736(97)08229-9.
    • Sone S, Takashima S, Li F, Yang Z, et al. Mass screening for lung cancer with mobile spiral computed tomography scanner. Lancet 1998+ADs-351: 1242-5. doi:10.1016/S0140-6736(97)08229-9.
    • (1998) Lancet , vol.351 , pp. 1242-1242
    • Sone, Z.1
  • 6
    • 0028939173 scopus 로고
    • CT of the chest: Minimal tube current required for good image quality with the least radiation dose
    • Mayo JR, Hartmanj TE, Lee KS, Primack SL, Vedal S, Muller NL. CT of the chest: minimal tube current required for good image quality with the least radiation dose. Am J Roentgenol 1995+ADs-164: 603-7.
    • (1995) Am J Roentgenol , vol.164 , pp. 603-603
    • Mayo, J.R.1    Hartmanj, T.E.2    Lee, K.S.3    Primack, S.L.4    Vedal, S.5    Muller, N.L.6
  • 7
    • 0034789877 scopus 로고    scopus 로고
    • Multi-slice computed tomography as a screening tool for colon cancer, lung cancer and coronary artery disease
    • doi:10.1007/s003300100950. PMid:11702131.
    • Schoepf UJ, Becker CR, Obuchowski NA, et al. Multi-slice computed tomography as a screening tool for colon cancer, lung cancer and coronary artery disease. Eur Radiol 2001+ADs-11: 1975-85. doi:10.1007/s003300100950. PMid:11702131.
    • (2001) Eur Radiol , vol.11 , pp. 1975-1975
    • Schoepf, N.A.1
  • 8
    • 33750315764 scopus 로고    scopus 로고
    • Survival of patients with stage i lung cancer detected on CT screening
    • doi:10.1056/NEJMoa060476. PMid:17065637.
    • The International Early Lung Cancer Action Program Investigators.Survival of patients with stage I lung cancer detected on CT screening. N Engl J Med 2006+ADs-355: 1763-71. doi:10.1056/NEJMoa060476. PMid:17065637.
    • (2006) N Engl J Med , vol.355 , pp. 1763-1763
  • 9
    • 33847691553 scopus 로고    scopus 로고
    • Computed tomography screening and lung cancer outcomes
    • doi:10.1001/jama.297.9.953. PMid:17341709.
    • Bach PB, Jett JR, Pastorino U, Tockman MS, Swensen SJ, Begg CB. Computed tomography screening and lung cancer outcomes. JAMA 2007+ADs-297: 953-61. doi:10.1001/jama.297.9.953. PMid:17341709.
    • (2007) JAMA , vol.297 , pp. 953-953
    • Bach, P.B.1    Jett, J.R.2    Pastorino, U.3    Tockman, M.S.4    Swensen, S.J.5    Begg, C.B.6
  • 10
    • 0037372749 scopus 로고    scopus 로고
    • Lung cancer screening with CT: Mayo Clinic experience
    • doi:10.1148/radiol.2263020036. PMid:12601181.
    • Swensen SJ, Jett JR, Hartman TE, et al. Lung cancer screening with CT: Mayo Clinic experience. Radiology 2003+ADs-226: 756-61. doi:10.1148/radiol. 2263020036. PMid:12601181.
    • (2003) Radiology , vol.226 , pp. 756-756
    • Swensen, T.E.1
  • 11
    • 43549102959 scopus 로고    scopus 로고
    • Estimating longterm effectiveness of lung cancer screening in the Mayo CT screening study
    • doi:10.1148/ radiol.2481071446. PMid:18458247.
    • McMahon PM, Kong CY, Johnson BE, et al. Estimating longterm effectiveness of lung cancer screening in the Mayo CT screening study. Radiology 2008+ADs-248: 278-87. doi:10.1148/ radiol.2481071446. PMid:18458247.
    • (2008) Radiology , vol.248 , pp. 278-278
    • McMahon, B.E.1
  • 12
    • 0344551795 scopus 로고    scopus 로고
    • Radiological examination for peripheral lung cancers and benign nodules less than 10 mm
    • doi:10.1016/S0169-5002(03)00360-X. PMid:14644516.
    • Ohtsuka T, Nomori H, Horio H, Naruke T, Suemasu K. Radiological examination for peripheral lung cancers and benign nodules less than 10 mm. Lung Cancer 2003+ADs-42: 291-6. doi:10.1016/S0169-5002(03)00360-X. PMid:14644516.
    • (2003) Lung Cancer , vol.42 , pp. 291-291
    • Ohtsuka, T.1    Nomori, H.2    Horio, H.3    Naruke, T.4    Suemasu, K.5
  • 13
    • 0033962497 scopus 로고    scopus 로고
    • Lung nodule enhancement at CT: Multicentric study
    • Swensen SJ, Viggiano RW, Midthun DE, et al. Lung nodule enhancement at CT: multicentric study. Radiology 2000+ADs-214: 73-80.
    • (2000) Radiology , vol.214 , pp. 73-73
    • Swensen, D.E.1
  • 14
    • 0041464868 scopus 로고    scopus 로고
    • Early lungcancer detection with spiral CT and positron emission tomography in heavy smokers: 2-year results
    • doi:10.1016/S0140-6736(03)14188-8.
    • Pastorino U, Bellomi M, Landoni C, De Fiori E. Early lungcancer detection with spiral CT and positron emission tomography in heavy smokers: 2-year results. Lancet 2003+ADs-362: 593-7. doi:10.1016/S0140-6736(03)14188-8.
    • (2003) Lancet , vol.362 , pp. 593-593
    • Pastorino, U.1    Bellomi, M.2    Landoni, C.3    De Fiori, E.4
  • 15
    • 35548995051 scopus 로고    scopus 로고
    • Evolution of pulmonary nodules55mm detected with low-dose CT in asymptomatic smokers
    • doi:10.1259/bjr/46019726. PMid:17928499.
    • Bellomi M, Rampinelli C, Veronesi G, Ferretti S, De Fiori E, Maisonneuve P. Evolution of pulmonary nodules55mm detected with low-dose CT in asymptomatic smokers. Br J Radiol 2007+ADs-80: 708-12. doi:10.1259/bjr/46019726. PMid:17928499.
    • (2007) Br J Radiol , vol.80 , pp. 708-708
    • Bellomi, M.1    Rampinelli, C.2    Veronesi, G.3    Ferretti, S.4    De Fiori, E.5    Maisonneuve, P.6
  • 16
    • 20144389751 scopus 로고    scopus 로고
    • CT screening for lung cancer: Five-year prospective experience
    • doi:10.1148/radiol.2351041662. PMid:15695622.
    • Swensen SJ, Jett JR, Hartman TE, et al. CT screening for lung cancer: five-year prospective experience. Radiology 2005+ADs-235: 259-65. doi:10.1148/radiol.2351041662. PMid:15695622.
    • (2005) Radiology , vol.235 , pp. 259-259
    • Swensen, T.E.1
  • 17
    • 1642296713 scopus 로고    scopus 로고
    • CT screening for lung cancer: Suspiciousness of nodules according to size on baseline scans
    • doi:10.1148/ radiol.2311030634. PMid:14990809.
    • Henschke CI, Yankelevitz DF, Naidich DP, et al. CT screening for lung cancer: suspiciousness of nodules according to size on baseline scans. Radiology 2004+ADs-231: 164-8. doi:10.1148/ radiol.2311030634. PMid:14990809.
    • (2004) Radiology , vol.231 , pp. 164-164
    • Henschke, D.P.1
  • 18
    • 37349024293 scopus 로고    scopus 로고
    • Lung cancer: Interobserver agreement on interpretation of pulmonary findings at low-dose CT
    • doi:10.1148/ radiol.2461062097. PMid:18024436.
    • Gierada D, Pilgram K, Ford M, et al. Lung cancer: interobserver agreement on interpretation of pulmonary findings at low-dose CT. Radiology 2008+ADs-246: 265-72. doi:10.1148/ radiol.2461062097. PMid:18024436.
    • (2008) Radiology , vol.246 , pp. 265-265
    • Gierada, M.1
  • 19
    • 27144449606 scopus 로고    scopus 로고
    • Guidelines for management of small pulmonary nodules detected on CT scans: A statement from the Fleischner Society
    • doi:10.1148/radiol.2372041887. PMid:16244247.
    • MacMahon H, Austin JH, Gamsu G, et al. Guidelines for management of small pulmonary nodules detected on CT scans: a statement from the Fleischner Society. Radiology 2005+ADs-237: 395-400. doi:10.1148/radiol.2372041887. PMid:16244247.
    • (2005) Radiology , vol.237 , pp. 395-395
    • MacMahon, G.1
  • 20
    • 67049132429 scopus 로고    scopus 로고
    • Accuracy and repeatibility of automatic volume calculation of small pulmonary nodules
    • doi:10.2214/ AJR.08.1825. PMid:19457831.
    • Rampinelli C, De Fiori E, Raimondi S, Bellomi M. Accuracy and repeatibility of automatic volume calculation of small pulmonary nodules. Am J Roentgenol 2009+ADs-192: 1657-61. doi:10.2214/ AJR.08.1825. PMid:19457831.
    • (2009) Am J Roentgenol , vol.192 , pp. 1657-1657
    • Rampinelli, C.1    De Fiori, E.2    Raimondi, S.3    Bellomi, M.4
  • 21
    • 33750374198 scopus 로고    scopus 로고
    • Characterization of the solitary pulmonary nodule: 18F-FDG PET versus nodule-enhancement CT
    • doi:10.2214/AJR.05.1166. PMid:17056930.
    • Christensen JA, Nathan MA, Mullan BP. Characterization of the solitary pulmonary nodule: 18F-FDG PET versus nodule-enhancement CT. AJR Am J Roentgenol 2006+ADs-187: 1361-7. doi:10.2214/AJR.05.1166. PMid:17056930.
    • (2006) AJR Am J Roentgenol , vol.187 , pp. 1361-1361
    • Christensen, J.A.1    Nathan, M.A.2    Mullan, B.P.3
  • 22
    • 43549126325 scopus 로고    scopus 로고
    • Lung cancer screening with low-dose computed tomography: A non-invasive diagnostic protocol for baseline lung nodules
    • doi:10.1016/j.lungcan.2008.01.001. PMid:18308420.
    • Veronesi G, Bellomi M, Mulshine JL, et al. Lung cancer screening with low-dose computed tomography: a non-invasive diagnostic protocol for baseline lung nodules. Lung Cancer 2008+ADs-61: 340-9. doi:10.1016/j.lungcan.2008.01.001. PMid:18308420.
    • (2008) Lung Cancer , vol.61 , pp. 340-340
    • Veronesi, J.L.1
  • 23
    • 52049123321 scopus 로고    scopus 로고
    • Difficulties encountered managing nodules detected during the first year of a lung cancer screening program
    • Veronesi G, Bellomi M, Scanagatta P, et al. Difficulties encountered managing nodules detected during the first year of a lung cancer screening program. J Thorac Cardiovasc Surg 2008+ADs-136: 611-7.
    • (2008) J Thorac Cardiovasc Surg , vol.136 , pp. 611-611
    • Veronesi, P.1
  • 24
    • 0036109223 scopus 로고    scopus 로고
    • CT screening for lung cancer: Frequency and significance of partsolid and nonsolid nodules
    • Henschke CI, Yankelevitz DF, Mirtcheva R, et al. CT screening for lung cancer: frequency and significance of partsolid and nonsolid nodules. AJR Am J Roentgenol 2002+ADs-178: 1053-7.
    • (2002) AJR Am J Roentgenol , vol.178 , pp. 1053-1053
    • Henschke, R.1
  • 25
    • 34548672818 scopus 로고    scopus 로고
    • Persistent pulmonary nodular ground-glass opacity at thin-section CT: Histopathologic comparisons
    • Ha YK, Young MS, Kyung SL. Persistent pulmonary nodular ground-glass opacity at thin-section CT: histopathologic comparisons. Radiology 2007+ADs-245: 267-75.
    • (2007) Radiology , vol.245 , pp. 267-267
    • Ha, Y.K.1    Young, M.S.2    Kyung, S.L.3
  • 26
    • 33846564385 scopus 로고    scopus 로고
    • Risk-based selection from the general population in a screening trial: Selection criteria, recruitment and power for the Dutch-Belgian randomised lung cancer multislice CT screening trial (NELSON)
    • doi:10.1002/ijc.22134.
    • van Ierse CA, de Koning HJ, Draisma G, et al. Risk-based selection from the general population in a screening trial: selection criteria, recruitment and power for the Dutch-Belgian randomised lung cancer multislice CT screening trial (NELSON). Int J Cancer 2006+ADs-120: 868-74. doi:10.1002/ijc.22134.
    • (2006) Int J Cancer , vol.120 , pp. 868-868
    • Van Ierse, C.A.1    De Koning, H.J.2    Draisma, G.3
  • 27
    • 84874037317 scopus 로고    scopus 로고
    • Board of Scientific Advisors.National Cancer Institute
    • Board of Scientific Advisors, National Cancer Institute. Meeting minutes, Bethesda, MD, (March 2005). http://deainfo.nci.nih.-gov/advisory/bsa/bsa0305/ 07mar05mins.htm
    • Meeting minutes, Bethesda, MD, (March 2005)
  • 29
    • 52049088874 scopus 로고    scopus 로고
    • Pathologic and molecular features of screening low-dose computed tomography (LDCT)-detected lung cancer: A baseline and 2-year repeat study
    • doi:10.1016/j.lungcan.2008.03.012. PMid:18450320.
    • Pelosi G, Sonzogni A, Veronesi G, et al. Pathologic and molecular features of screening low-dose computed tomography (LDCT)-detected lung cancer: a baseline and 2-year repeat study. Lung Cancer 2008+ADs-62: 202-14. doi:10.1016/j.lungcan.2008.03.012. PMid:18450320.
    • (2008) Lung Cancer , vol.62 , pp. 202-202
    • Pelosi, G.1
  • 30
    • 42549106938 scopus 로고    scopus 로고
    • Mean sojourn time and effectiveness of mortality reduction for lung cancer screening with computed tomography
    • doi:10.1002/ ijc.23413.
    • Chien C-R, Chen TH-H. Mean sojourn time and effectiveness of mortality reduction for lung cancer screening with computed tomography. Int J Cancer 2008+ADs-122: 2594-9. doi:10.1002/ ijc.23413.
    • (2008) Int J Cancer , vol.122 , pp. 2594-2594
    • Chien, C.-R.1    Chen, T.-H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.