메뉴 건너뛰기




Volumn 42, Issue 4, 2010, Pages 461-467

Methodology for the calculation of response factors through experimental tests and validation with simulation

Author keywords

Guarded hot box test; Response factors; Simulation; Wall transient heat flux

Indexed keywords

BUILDING PRODUCTS; DYNAMIC TESTING; EXPERIMENTAL TEST; FINITE VOLUME; HEAT FLOWS; MATERIAL PROPERTY; RESPONSE FACTOR; SIMULATION CODE; TEST RESPONSE; THERMAL CHARACTERISTICS; THERMO-PHYSICAL PROPERTY; TRANSIENT HEAT; TRANSIENT REGIME;

EID: 77649185640     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2009.10.015     Document Type: Article
Times cited : (41)

References (19)
  • 4
    • 0002662812 scopus 로고
    • Cooling load calculations by thermal response factor method
    • Stephenson D.G., and Mitalas G.P. Cooling load calculations by thermal response factor method. ASHRAE Transactions 73 part 1 (1967)
    • (1967) ASHRAE Transactions , vol.73 , Issue.PART 1
    • Stephenson, D.G.1    Mitalas, G.P.2
  • 5
    • 20344381329 scopus 로고    scopus 로고
    • Application of conduction transfer functions and periodic response factors in cooling load calculation procedures
    • Ipseng I. Application of conduction transfer functions and periodic response factors in cooling load calculation procedures. ASHRAE Transactions 110 part 2 (2004)
    • (2004) ASHRAE Transactions , vol.110 , Issue.PART 2
    • Ipseng, I.1
  • 6
    • 0004173698 scopus 로고
    • Chartered Institution of Building Services Engineers, London
    • CIBSE Guide Volume A (1986), Chartered Institution of Building Services Engineers, London
    • (1986) CIBSE Guide Volume A
  • 7
    • 0010929997 scopus 로고
    • A note on response factors and conduction transfer functions
    • Peavy B.A. A note on response factors and conduction transfer functions. ASHRAE Transactions 84 part I (1978) 688-690
    • (1978) ASHRAE Transactions , vol.84 , Issue.PART I , pp. 688-690
    • Peavy, B.A.1
  • 8
    • 10444224739 scopus 로고    scopus 로고
    • Three-dimensional conduction z-transfer functions coefficients determined from the response factors
    • Kossecka E., and Kosny J. Three-dimensional conduction z-transfer functions coefficients determined from the response factors. Energy and Buildings 37 (2005) 301-310
    • (2005) Energy and Buildings , vol.37 , pp. 301-310
    • Kossecka, E.1    Kosny, J.2
  • 9
    • 43049117169 scopus 로고    scopus 로고
    • Static and dynamic thermal characterisation of a hollow brick wall: test and numerical análisis
    • Sala J.M., Urresti A., Martin K., Flores I., and Apaolaza A. Static and dynamic thermal characterisation of a hollow brick wall: test and numerical análisis. Energy and Buildings 40 (2008) 1513-1520
    • (2008) Energy and Buildings , vol.40 , pp. 1513-1520
    • Sala, J.M.1    Urresti, A.2    Martin, K.3    Flores, I.4    Apaolaza, A.5
  • 10
    • 0015758048 scopus 로고
    • Application of system identification techniques to the determination of thermal response factors from experimental data
    • Pedersen C.O., and Mouen E.D. Application of system identification techniques to the determination of thermal response factors from experimental data. ASHRAE Transactions 79 part II (1973) 127-135
    • (1973) ASHRAE Transactions , vol.79 , Issue.PART II , pp. 127-135
    • Pedersen, C.O.1    Mouen, E.D.2
  • 12
    • 0003941440 scopus 로고    scopus 로고
    • Thermal insulation, Determination of steady-state thermal transmission properties, Calibrated and guarded hot box
    • EN ISO 8990
    • EN ISO 8990:1996, Thermal insulation, Determination of steady-state thermal transmission properties, Calibrated and guarded hot box.
    • (1996)
  • 13
    • 73649084476 scopus 로고    scopus 로고
    • Thermal performance of building materials and products, Determination of thermal resistance by means of guarded hot plate and heat flux meter methods, Products of high and medium thermal resistance
    • EN 12667
    • EN 12667:2002, Thermal performance of building materials and products, Determination of thermal resistance by means of guarded hot plate and heat flux meter methods, Products of high and medium thermal resistance.
    • (2002)
  • 14
    • 20744436196 scopus 로고    scopus 로고
    • Thermal performance of building products and components, Specific criteria for the assessment of laboratories measuring heat transfer properties, Part 3: Measurements by heat flux meter method
    • EN 1946-3
    • EN 1946-3:1999, Thermal performance of building products and components, Specific criteria for the assessment of laboratories measuring heat transfer properties, Part 3: measurements by heat flux meter method.
    • (1999)
  • 15
    • 0010811911 scopus 로고    scopus 로고
    • Building components and building elements, Thermal resistance and thermal transmittance, Calculation method
    • EN ISO 6946
    • EN ISO 6946:1997, Building components and building elements, Thermal resistance and thermal transmittance, Calculation method.
    • (1997)
  • 17
    • 77649192148 scopus 로고    scopus 로고
    • Thermal performance of building products and components, Specific criteria for the assessment of laboratories measuring heat transfer properties, Part 4: Measurements by hot box methods
    • EN 1946-4
    • EN 1946-4:2001, Thermal performance of building products and components, Specific criteria for the assessment of laboratories measuring heat transfer properties, Part 4: measurements by hot box methods.
    • (2001)
  • 18
    • 29244451965 scopus 로고    scopus 로고
    • Masonry and masonry products-methods for determining design thermal values
    • EN 1745
    • EN 1745:2002, Masonry and masonry products-methods for determining design thermal values.
    • (2002)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.