메뉴 건너뛰기




Volumn 12, Issue 3, 2010, Pages 306-313

Accuracy of pedicle screw placement in the lumbosacral spine using conventional technique: Computed tomography postoperative assessment in 102 consecutive patients - Clinical article

Author keywords

Pedicle screw; Screw misplacement; Spinal fusion; Spinal instrumentation; Transpedicular screw fixation

Indexed keywords

ANTIBIOTIC AGENT;

EID: 77649159270     PISSN: 15475654     EISSN: 15475646     Source Type: Journal    
DOI: 10.3171/2009.9.SPINE09261     Document Type: Article
Times cited : (114)

References (39)
  • 1
    • 18844477686 scopus 로고    scopus 로고
    • The effect of transpedicular screw misplacement on late spinal stability
    • Açikbaş SC, Arslan FY, Tuncer MR: The effect of transpedicular screw misplacement on late spinal stability. Acta Neurochir (Wien) 145:949-955, 2003
    • (2003) Acta Neurochir (Wien) , vol.145 , pp. 949-955
    • Açikbaş, S.C.1    Arslan, F.Y.2    Tuncer, M.R.3
  • 2
    • 0034061781 scopus 로고
    • Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine
    • Amiot LP, Lang K, Putzier M, Zippel H, Labelle H: Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine (Phila Pa 1976) 25:606-614, 2000
    • (1976) Spine (Phila Pa , vol.25
    • Amiot, L.P.1    Lang, K.2    Putzier, M.3    Zippel, H.4    Labelle, H.5
  • 4
    • 0037111853 scopus 로고
    • Image-guided spine surgery: A cadaver study comparing conventional open laminoforaminotomy and two image-guided techniques for pedicle screw placement in posterolateral fusion and nonfusion models
    • Austin MS, Vaccaro AR, Brislin B, Nachwalter R, Hilibrand AS, Albert TJ: Image-guided spine surgery: a cadaver study comparing conventional open laminoforaminotomy and two image-guided techniques for pedicle screw placement in posterolateral fusion and nonfusion models. Spine (Phila Pa 1976) 27:2503-2508, 2002
    • (1976) Spine (Phila Pa , vol.27
    • Austin, M.S.1    Vaccaro, A.R.2    Brislin, B.3    Nachwalter, R.4    Hilibrand, A.S.5    Albert, T.J.6
  • 7
    • 33845487571 scopus 로고    scopus 로고
    • Stepwise methodology for plain radiographic assessment of pedicle screw placement: A comparison with computed tomography
    • Choma TJ, Denis F, Lonstein JE, Perra JH, Schwender JD, Garvey TA, et al: Stepwise methodology for plain radiographic assessment of pedicle screw placement: a comparison with computed tomography. J Spinal Disord Tech 19:547-553, 2006
    • (2006) J Spinal Disord Tech , vol.19 , pp. 547-553
    • Choma, T.J.1    Denis, F.2    Lonstein, J.E.3    Perra, J.H.4    Schwender, J.D.5    Garvey, T.A.6
  • 8
    • 0031410282 scopus 로고
    • Anatomic relations between the lumbar pedicle and the adjacent neural structures
    • Ebraheim NA, Xu R, Darwich M, Yeasting RA: Anatomic relations between the lumbar pedicle and the adjacent neural structures. Spine (Phila Pa 1976) 22:2338-2341, 1997
    • (1976) Spine (Phila Pa , vol.22
    • Ebraheim, N.A.1    Xu, R.2    Darwich, M.3    Yeasting, R.A.4
  • 9
    • 0029044493 scopus 로고
    • Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography
    • Farber GL, Place HM, Mazur RA, Jones DE, Damiano TR: Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography. Spine (Phila Pa 1976) 20:1494-1499, 1995
    • (1976) Spine (Phila Pa , vol.20
    • Farber, G.L.1    Place, H.M.2    Mazur, R.A.3    Jones, D.E.4    Damiano, T.R.5
  • 10
    • 0031573532 scopus 로고
    • Volvo Award winner in clinical studies. Degenerative lumbar spondylolisthesis with spinal stenosis: A prospective, randomized study comparing decompressive laminectomy and arthrodesis with and without spinal instrumentation
    • Fischgrund JS, Mackay M, Herkowitz HN, Brower R, Montgomery DM, Kurz LT: 1997 Volvo Award winner in clinical studies. Degenerative lumbar spondylolisthesis with spinal stenosis: a prospective, randomized study comparing decompressive laminectomy and arthrodesis with and without spinal instrumentation. Spine (Phila Pa 1976) 22:2807-2812, 1997
    • (1976) Spine (Phila Pa , vol.22
    • Fischgrund, J.S.1    Mackay, M.2    Herkowitz, H.N.3    Brower, R.4    Montgomery, D.M.5    Kurz, L.T.6
  • 11
    • 0033559587 scopus 로고
    • A randomized prospective study of posterolateral lumbar fusion. Outcomes with and without pedicle screw instrumentation
    • France JC, Yaszemski MJ, Lauerman WC, Cain JE, Glover JM, Lawson KJ, et al: A randomized prospective study of posterolateral lumbar fusion. Outcomes with and without pedicle screw instrumentation. Spine (Phila Pa 1976) 24:553-560, 1999
    • (1976) Spine (Phila Pa , vol.24
    • France, J.C.1    Yaszemski, M.J.2    Lauerman, W.C.3    Cain, J.E.4    Glover, J.M.5    Lawson, K.J.6
  • 12
    • 0033794424 scopus 로고    scopus 로고
    • The use of pedicle-screw internal fixation for the operative treatment of spinal disorders
    • Gaines RW Jr: The use of pedicle-screw internal fixation for the operative treatment of spinal disorders. J Bone Joint Surg Am 82-A:1458-1476, 2000
    • (2000) J Bone Joint Surg Am , vol.82-A , pp. 1458-1476
    • Gaines Jr, R.W.1
  • 13
    • 0025267440 scopus 로고
    • Accuracy of pedicular screw placement in vivo
    • Gertzbein SD, Robbins SE: Accuracy of pedicular screw placement in vivo. Spine (Phila Pa 1976) 15:11-14, 1990
    • (1976) Spine (Phila Pa , vol.15
    • Gertzbein, S.D.1    Robbins, S.E.2
  • 14
    • 58149164617 scopus 로고    scopus 로고
    • Perioperative complications of primary posterior lumbar interbody fusion for nonisthmic spondylolisthesis: Analysis of risk factors
    • Hosono N, Namekata M, Makino T, Miwa T, Kaito T, Kaneko N, et al: Perioperative complications of primary posterior lumbar interbody fusion for nonisthmic spondylolisthesis: analysis of risk factors. J Neurosurg Spine 9:403-407, 2008
    • (2008) J Neurosurg Spine , vol.9 , pp. 403-407
    • Hosono, N.1    Namekata, M.2    Makino, T.3    Miwa, T.4    Kaito, T.5    Kaneko, N.6
  • 15
    • 0036458441 scopus 로고    scopus 로고
    • Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations
    • Jutte PC, Castelein RM: Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations. Eur Spine J 11:594-598, 2002
    • (2002) Eur Spine J , vol.11 , pp. 594-598
    • Jutte, P.C.1    Castelein, R.M.2
  • 16
    • 33745788417 scopus 로고    scopus 로고
    • Karim A, Mukherjee D, Gonzalez-Cruz J, Ogden A, Smith D, Nanda A: Accuracy of pedicle screw placement for lumbar fusion using anatomical landmarks versus open laminectomy: a comparison of two surgical techniques in cadaveric specimens. Neurosurgery 59 (1 Suppl):ONS13-ONS19, 2006
    • Karim A, Mukherjee D, Gonzalez-Cruz J, Ogden A, Smith D, Nanda A: Accuracy of pedicle screw placement for lumbar fusion using anatomical landmarks versus open laminectomy: a comparison of two surgical techniques in cadaveric specimens. Neurosurgery 59 (1 Suppl):ONS13-ONS19, 2006
  • 17
    • 77649128967 scopus 로고    scopus 로고
    • Accuracy of pedicle screw insertion without computer assistance
    • Khan SA, Lukhele M, Nainkin L: Accuracy of pedicle screw insertion without computer assistance. J Bone Joint Surg Br 90 (Suppl III):462, 2008
    • (2008) J Bone Joint Surg Br , vol.90 , Issue.SUPPL. III , pp. 462
    • Khan, S.A.1    Lukhele, M.2    Nainkin, L.3
  • 18
    • 25444518981 scopus 로고
    • Evaluation of pedicle screw placement in the deformed spine using intraoperative plain radiographs: A comparison with computerized tomography
    • Kim YJ, Lenke LG, Cheh G, Riew KD: Evaluation of pedicle screw placement in the deformed spine using intraoperative plain radiographs: a comparison with computerized tomography. Spine (Phila Pa 1976) 30:2084-2088, 2005
    • (1976) Spine (Phila Pa , vol.30
    • Kim, Y.J.1    Lenke, L.G.2    Cheh, G.3    Riew, K.D.4
  • 19
    • 33846683025 scopus 로고
    • Pedicle screw placement accuracy: A meta-analysis
    • Kosmopoulos V, Schizas C: Pedicle screw placement accuracy: a meta-analysis. Spine (Phila Pa 1976) 32:E111-E120, 2007
    • (1976) Spine (Phila Pa , vol.32
    • Kosmopoulos, V.1    Schizas, C.2
  • 20
    • 0033834616 scopus 로고    scopus 로고
    • Accuracy of pedicle screw insertion with and without computer assistance: A randomised controlled clinical study in 100 consecutive patients
    • Laine T, Lund T, Ylikoski M, Lohikoski J, Schlenzka D: Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J 9:235-240, 2000
    • (2000) Eur Spine J , vol.9 , pp. 235-240
    • Laine, T.1    Lund, T.2    Ylikoski, M.3    Lohikoski, J.4    Schlenzka, D.5
  • 21
    • 0031438992 scopus 로고    scopus 로고
    • Accuracy of pedicle screw insertion: A prospective CT study in 30 low back patients
    • Laine T, Mäkitalo K, Schlenzka D, Tallroth K, Poussa M, Alho A: Accuracy of pedicle screw insertion: a prospective CT study in 30 low back patients. Eur Spine J 6:402-405, 1997
    • (1997) Eur Spine J , vol.6 , pp. 402-405
    • Laine, T.1    Mäkitalo, K.2    Schlenzka, D.3    Tallroth, K.4    Poussa, M.5    Alho, A.6
  • 22
    • 1842564006 scopus 로고
    • Assessment of pedicle screw placement utilizing conventional radiography and computed tomography: A proposed systematic approach to improve accuracy of interpretation
    • Learch TJ, Massie JB, Pathria MN, Ahlgren BA, Garfin SR: Assessment of pedicle screw placement utilizing conventional radiography and computed tomography: a proposed systematic approach to improve accuracy of interpretation. Spine (Phila Pa 1976) 29:767-773, 2004
    • (1976) Spine (Phila Pa , vol.29
    • Learch, T.J.1    Massie, J.B.2    Pathria, M.N.3    Ahlgren, B.A.4    Garfin, S.R.5
  • 23
    • 23244450640 scopus 로고
    • Accuracy of computerized frameless stereotactic image-guided pedicle screw placement into previously fused lumbar spines
    • Lim MR, Girardi FP, Yoon SC, Huang RC, Cammisa FP Jr: Accuracy of computerized frameless stereotactic image-guided pedicle screw placement into previously fused lumbar spines. Spine (Phila Pa 1976) 30:1793-1798, 2005
    • (1976) Spine (Phila Pa , vol.30
    • Lim, M.R.1    Girardi, F.P.2    Yoon, S.C.3    Huang, R.C.4    Cammisa Jr, F.P.5
  • 25
    • 0031750966 scopus 로고    scopus 로고
    • Efficacy of pedicle screw fixation in the treatment of spinal instability and failed back surgery: A 5-year review
    • Masferrer R, Gomez CH, Karahalios DG, Sonntag VK: Efficacy of pedicle screw fixation in the treatment of spinal instability and failed back surgery: a 5-year review. J Neurosurg 89:371-377, 1998
    • (1998) J Neurosurg , vol.89 , pp. 371-377
    • Masferrer, R.1    Gomez, C.H.2    Karahalios, D.G.3    Sonntag, V.K.4
  • 28
    • 61549092238 scopus 로고    scopus 로고
    • Placement of thoracolumbar pedicle screws using three-dimensional image guidance: Experience in a large patient cohort. Clinical article
    • Nottmeier EW, Seemer W, Young PM: Placement of thoracolumbar pedicle screws using three-dimensional image guidance: experience in a large patient cohort. Clinical article. J Neurosurg Spine 10:33-39, 2009
    • (2009) J Neurosurg Spine , vol.10 , pp. 33-39
    • Nottmeier, E.W.1    Seemer, W.2    Young, P.M.3
  • 29
    • 33646459226 scopus 로고    scopus 로고
    • Surgical complications of posterior lumbar interbody fusion with total facetectomy in 251 patients
    • Okuda S, Miyauchi A, Oda T, Haku T, Yamamoto T, Iwasaki M: Surgical complications of posterior lumbar interbody fusion with total facetectomy in 251 patients. J Neurosurg Spine 4:304-309, 2006
    • (2006) J Neurosurg Spine , vol.4 , pp. 304-309
    • Okuda, S.1    Miyauchi, A.2    Oda, T.3    Haku, T.4    Yamamoto, T.5    Iwasaki, M.6
  • 30
    • 7944236645 scopus 로고    scopus 로고
    • Clinical outcomes and complications associated with pedicle screw fixation-augmented lumbar interbody fusion
    • Rivet DJ, Jeck D, Brennan J, Epstein A, Lauryssen C: Clinical outcomes and complications associated with pedicle screw fixation-augmented lumbar interbody fusion. J Neurosurg Spine 1:261-266, 2004
    • (2004) J Neurosurg Spine , vol.1 , pp. 261-266
    • Rivet, D.J.1    Jeck, D.2    Brennan, J.3    Epstein, A.4    Lauryssen, C.5
  • 31
    • 0022625438 scopus 로고
    • Internal fixation of the lumbar spine with pedicle screw plating
    • Roy-Camille R, Saillant G, Mazel C: Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop Relat Res 203:7-17, 1986
    • (1986) Clin Orthop Relat Res , vol.203 , pp. 7-17
    • Roy-Camille, R.1    Saillant, G.2    Mazel, C.3
  • 32
    • 34248550738 scopus 로고    scopus 로고
    • Computer tomography assessment of pedicle screw insertion in percutaneous posterior transpedicular stabilization
    • Schizas C, Michel J, Kosmopoulos V, Theumann N: Computer tomography assessment of pedicle screw insertion in percutaneous posterior transpedicular stabilization. Eur Spine J 16:613-617, 2007
    • (2007) Eur Spine J , vol.16 , pp. 613-617
    • Schizas, C.1    Michel, J.2    Kosmopoulos, V.3    Theumann, N.4
  • 33
    • 0031057090 scopus 로고
    • Accuracy of computer-assisted pedicle screw placement. An in vivo computed tomography analysis
    • Schwarzenbach O, Berlemann U, Jost B, Visarius H, Arm E, Langlotz F, et al: Accuracy of computer-assisted pedicle screw placement. An in vivo computed tomography analysis. Spine (Phila Pa 1976) 22:452-458, 1997
    • (1976) Spine (Phila Pa , vol.22
    • Schwarzenbach, O.1    Berlemann, U.2    Jost, B.3    Visarius, H.4    Arm, E.5    Langlotz, F.6
  • 34
    • 0022642420 scopus 로고
    • Segmental spine plates with pedicle screw fixation. A new internal fixation device for disorders of the lumbar and thoracolumbar spine
    • Steffee AD, Biscup RS, Sitkowski DJ: Segmental spine plates with pedicle screw fixation. A new internal fixation device for disorders of the lumbar and thoracolumbar spine. Clin Orthop Relat Res 203:45-53, 1986
    • (1986) Clin Orthop Relat Res , vol.203 , pp. 45-53
    • Steffee, A.D.1    Biscup, R.S.2    Sitkowski, D.J.3
  • 35
    • 0029609525 scopus 로고
    • Internal fixation (pedicle screw fixation) for fusions of the lumbar spine
    • Vaccaro AR, Garfin SR: Internal fixation (pedicle screw fixation) for fusions of the lumbar spine. Spine 20 (24 Suppl):S157-S165, 1995
    • (1995) Spine , vol.20 , Issue.24 SUPPL.
    • Vaccaro, A.R.1    Garfin, S.R.2
  • 36
    • 0023790873 scopus 로고
    • Spinal pedicle fixation: Reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement
    • Weinstein JN, Spratt KF, Spengler D, Brick C, Reid S: Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine (Phila Pa 1976) 13:1012-1018, 1988
    • (1976) Spine (Phila Pa , vol.13
    • Weinstein, J.N.1    Spratt, K.F.2    Spengler, D.3    Brick, C.4    Reid, S.5
  • 37
    • 77649095555 scopus 로고    scopus 로고
    • Transpedicular screw fixation in the thoracic and lumbar spine with a novel cannulated poliaxial screw system
    • Weise L, Suess O, Picht T, Kombos T: Transpedicular screw fixation in the thoracic and lumbar spine with a novel cannulated poliaxial screw system. Medical Devices: Evidence and Research 1:33-39, 2008
    • (2008) Medical Devices: Evidence and Research , vol.1 , pp. 33-39
    • Weise, L.1    Suess, O.2    Picht, T.3    Kombos, T.4
  • 38
    • 0034099254 scopus 로고
    • Clinical evaluation and computed tomography scan analysis of screw tracts after percutaneous insertion of pedicle screws in the lumbar spine
    • Wiesner L, Kothe R, Schulitz KP, Rüther W: Clinical evaluation and computed tomography scan analysis of screw tracts after percutaneous insertion of pedicle screws in the lumbar spine. Spine (Phila Pa 1976) 25:615-621, 2000
    • (1976) Spine (Phila Pa , vol.25
    • Wiesner, L.1    Kothe, R.2    Schulitz, K.P.3    Rüther, W.4
  • 39
    • 0028046151 scopus 로고
    • Comprehensive literature review. Pedicle screw fixation devices
    • Yahiro MA: Comprehensive literature review. Pedicle screw fixation devices. Spine (Phila Pa 1976) 19 (20 Suppl):S2274-S2278, 1994
    • (1976) Spine (Phila Pa , vol.19 , Issue.20 SUPPL.
    • Yahiro, M.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.