메뉴 건너뛰기




Volumn 5, Issue 3, 2009, Pages 219-224

Comparison of solid-phase extraction and solid-phase microextraction using octadecylsilane phase for the determination of pesticides in water samples

Author keywords

Gas chromatography mass spectrometry (GCMS); Pesticides analysis; Solid phase extraction (SPE); Solid phase microextraction (SPME); Water analysis

Indexed keywords

EXTRACTION; GAS CHROMATOGRAPHY; MASS SPECTROMETRY; PHASE SEPARATION; WATER TREATMENT;

EID: 77649139374     PISSN: 15734110     EISSN: None     Source Type: Journal    
DOI: 10.2174/157341109788680309     Document Type: Article
Times cited : (9)

References (22)
  • 1
    • 40849124384 scopus 로고    scopus 로고
    • Analysis of 17 polar to semi-polar pesticides in the Ebro river delta during the main growing season of rice by automated on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry
    • Kuster, M.; López de Alda, M.J.; Barata, C.; Raldúa, D.; Barceló, D. Analysis of 17 polar to semi-polar pesticides in the Ebro river delta during the main growing season of rice by automated on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry. Talanta, 2008, 75, 390-401.
    • (2008) Talanta , vol.75 , pp. 390-401
    • Kuster, M.1    López de Alda, M.J.2    Barata, C.3    Raldúa, D.4    Barceló, D.5
  • 2
    • 36549035732 scopus 로고    scopus 로고
    • Triazophos residues and dissipation rates in wheat crops and soil
    • Li, W.; Qiu, S.P.; Wu, Y.J. Triazophos residues and dissipation rates in wheat crops and soil. Ecotox. Environ. Safe, 2008, 69, 312- 316.
    • (2008) Ecotox. Environ. Safe , vol.69 , pp. 312-316
    • Li, W.1    Qiu, S.P.2    Wu, Y.J.3
  • 3
    • 14844333262 scopus 로고    scopus 로고
    • Assessment of pesticides contamination in soil samples from an intensive horticulture area, using ultrasonic extraction and gas chromatography-mass spectrometry
    • Goncalves, C.; Alpendurada, M.F. Assessment of pesticides contamination in soil samples from an intensive horticulture area, using ultrasonic extraction and gas chromatography-mass spectrometry. Talanta, 2005, 65, 1179-1189.
    • (2005) Talanta , vol.65 , pp. 1179-1189
    • Goncalves, C.1    Alpendurada, M.F.2
  • 4
    • 36348983217 scopus 로고    scopus 로고
    • Occurrence of fungicide and insecticide residues in trade samples of leafy vegetables
    • González-Rodríguez, R.M., Rial-Otero R., Cancho-Grande B., Simal-Gandara J. Occurrence of fungicide and insecticide residues in trade samples of leafy vegetables. Food Chem., 2008, 107, 1342- 1347.
    • (2008) Food Chem , vol.107 , pp. 1342-1347
    • González-Rodríguez, R.M.1    Rial-Otero, R.2    Cancho-Grande, B.3    Simal-Gandara, J.4
  • 6
    • 0034802839 scopus 로고    scopus 로고
    • Determination of tebufenpyrad and oxadiazon by solid-phase microextraction and gas chromatography-mass spectrometry
    • Navalón, A.; Prieto, A.; Araujo, L.; Vilchez, J.L. Determination of tebufenpyrad and oxadiazon by solid-phase microextraction and gas chromatography-mass spectrometry. Chromatographia, 2001, 54, 377-382.
    • (2001) Chromatographia , vol.54 , pp. 377-382
    • Navalón, A.1    Prieto, A.2    Araujo, L.3    Vilchez, J.L.4
  • 7
    • 34250377242 scopus 로고    scopus 로고
    • MEKC combined with SPE and sample stacking for multiple analysis of pesticides in water samples at the ng/L level
    • Ravelo-Pérez, L.M.; Hernández-Borges, J.; Cifuentes, A.; Rodríguez-Delgado, M.A. MEKC combined with SPE and sample stacking for multiple analysis of pesticides in water samples at the ng/L level. Electrophoresis, 2007, 28, 1805-1814.
    • (2007) Electrophoresis , vol.28 , pp. 1805-1814
    • Ravelo-Pérez, L.M.1    Hernández-Borges, J.2    Cifuentes, A.3    Rodríguez-Delgado, M.A.4
  • 8
    • 34247598252 scopus 로고    scopus 로고
    • Determination of several pesticides in water by solid-phase extraction, liquid chromatography and electrospray tandem mass spectrometry
    • Rodrigues, A.M.; Ferreira, V.; Cardoso, V.V.; Ferreira, E.; Benoliel, M.J. Determination of several pesticides in water by solid-phase extraction, liquid chromatography and electrospray tandem mass spectrometry. J. Chromatogr. A, 2007, 1150, 267- 278.
    • (2007) J. Chromatogr. A , vol.1150 , pp. 267-278
    • Rodrigues, A.M.1    Ferreira, V.2    Cardoso, V.V.3    Ferreira, E.4    Benoliel, M.J.5
  • 9
    • 33645067620 scopus 로고    scopus 로고
    • Multi-residue analysis of some polar pesticides in water samples with SPE and LC-MS-MS
    • Liu, F.; Bischoff, G.; Pestemer, W.; Xu, W.; Kofoet, A. Multi-residue analysis of some polar pesticides in water samples with SPE and LC-MS-MS. Chromatographia, 2006, 63, 233-237.
    • (2006) Chromatographia , vol.63 , pp. 233-237
    • Liu, F.1    Bischoff, G.2    Pestemer, W.3    Xu, W.4    Kofoet, A.5
  • 10
    • 33751241389 scopus 로고    scopus 로고
    • Contamination levels of selected organochlorine and organophosphate pesticides in the Selangor River, Malaysia between 2002 and 2003
    • Leong, K.H.; Benjamin Tan, L.L.; Mustafa, A.M. Contamination levels of selected organochlorine and organophosphate pesticides in the Selangor River, Malaysia between 2002 and 2003. Chemosphere, 2007, 66, 1153-1159.
    • (2007) Chemosphere , vol.66 , pp. 1153-1159
    • Leong, K.H.1    Benjamin Tan, L.L.2    Mustafa, A.M.3
  • 12
    • 33847103548 scopus 로고    scopus 로고
    • Multiresidue analysis of three groups of pesticides in washing waters from olive processing by solid-phase extraction-gas chromatography with electron capture and thermionic specific detection
    • Guardia-Rubio, M.; Ruiz-Medina, A.; Pascual-Reguera, M.I.; Fernández de Córdova, M.L. Multiresidue analysis of three groups of pesticides in washing waters from olive processing by solid-phase extraction-gas chromatography with electron capture and thermionic specific detection. Microchem. J., 2007, 85, 257-264.
    • (2007) Microchem. J. , vol.85 , pp. 257-264
    • Guardia-Rubio, M.1    Ruiz-Medina, A.2    Pascual-Reguera, M.I.3    Fernández de Córdova, M.L.4
  • 13
    • 33749252696 scopus 로고    scopus 로고
    • n multiresidue determination of amidosulfuron, azimsulfuron, nicosulfuron, thifensulfuron methyl, tribenuron methyl and azoxystrobin in surface waters
    • n multiresidue determination of amidosulfuron, azimsulfuron, nicosulfuron, thifensulfuron methyl, tribenuron methyl and azoxystrobin in surface waters. Anal. Chim. Acta, 2006, 579, 146-151.
    • (2006) Anal. Chim. Acta , vol.579 , pp. 146-151
    • Polati, S.1    Bottaro, M.2    Frascarolo, P.3    Gosetti, F.4    Gianotti, V.5    Gennaro, M.C.6
  • 14
    • 33745991950 scopus 로고    scopus 로고
    • Study of presence of pesticides in surface waters in the Ebro river basin (Spain)
    • Claver, A.; Peña, O.; Rodríguez, L.; Ovelleiro, J.L. Study of presence of pesticides in surface waters in the Ebro river basin (Spain). Chemosphere, 2006, 64, 1437-1443.
    • (2006) Chemosphere , vol.64 , pp. 1437-1443
    • Claver, A.1    Peña, O.2    Rodríguez, L.3    Ovelleiro, J.L.4
  • 15
    • 34347340505 scopus 로고    scopus 로고
    • Determination of organochlorine pesticides in ground water samples using solid-phase microextraction by gas chromatography-electron capture detection
    • Júnior, J.L.R., Ré-Poppi, N. Determination of organochlorine pesticides in ground water samples using solid-phase microextraction by gas chromatography-electron capture detection. Talanta, 2007, 72, 1833-1841.
    • (2007) Talanta , vol.72 , pp. 1833-1841
    • Júnior, J.L.R.1    Ré-Poppi, N.2
  • 16
    • 34247353772 scopus 로고    scopus 로고
    • Analysis of chloroacetanilide herbicides in water samples by solid-phase microextraction coupled with gas chromatography-mass spectrometry
    • Xu, X.; Yang, H.; Wang, L.; Han, B.; Wang, X.; Lee, F.S.C. Analysis of chloroacetanilide herbicides in water samples by solid-phase microextraction coupled with gas chromatography-mass spectrometry. Anal. Chim. Acta, 2007, 591, 87-96.
    • (2007) Anal. Chim. Acta , vol.591 , pp. 87-96
    • Xu, X.1    Yang, H.2    Wang, L.3    Han, B.4    Wang, X.5    Lee, F.S.C.6
  • 17
    • 33846207578 scopus 로고    scopus 로고
    • Optimisation and validation of a solid-phase microextraction method for simultaneous determination of different types of pesticides in water by gas chromatography-mass spectrometry
    • Beceiro-González, E.; Concha-Grana, E.; Guimaraes, A.; Goncalves, C.; Muniategui-Lorenzo, S.; Alpendurada, M.F. Optimisation and validation of a solid-phase microextraction method for simultaneous determination of different types of pesticides in water by gas chromatography-mass spectrometry. J. Chromatogr. A, 2007, 1141, 165-173.
    • (2007) J. Chromatogr. A , vol.1141 , pp. 165-173
    • Beceiro-González, E.1    Concha-Grana, E.2    Guimaraes, A.3    Goncalves, C.4    Muniategui-Lorenzo, S.5    Alpendurada, M.F.6
  • 18
    • 27744506782 scopus 로고    scopus 로고
    • Development of an SPME-GC-MS/MS method for the determination of pesticides in rainwater: Laboratory and field experiments
    • Sauret-Szczepanski, N.; Mirabel, P.; Wortham, H. Development of an SPME-GC-MS/MS method for the determination of pesticides in rainwater: Laboratory and field experiments. Environ. Pollut., 2006, 139, 133-142.
    • (2006) Environ. Pollut. , vol.139 , pp. 133-142
    • Sauret-Szczepanski, N.1    Mirabel, P.2    Wortham, H.3
  • 19
    • 0000559618 scopus 로고    scopus 로고
    • Solid-phase microextraction of PAHs from aqueous samples using fibers coated with HPLC chemically bonded silica stationary phases
    • Liu, Y.; Lee, M.L.; Hageman, K.J.; Yang, Y.; Hawthorne, S.B. Solid-phase microextraction of PAHs from aqueous samples using fibers coated with HPLC chemically bonded silica stationary phases. Anal. Chem., 1997, 69, 5001-5005.
    • (1997) Anal. Chem. , vol.69 , pp. 5001-5005
    • Liu, Y.1    Lee, M.L.2    Hageman, K.J.3    Yang, Y.4    Hawthorne, S.B.5
  • 20
    • 0000412010 scopus 로고    scopus 로고
    • Solid phase microextraction for quantitative analysis in non- equilibrium situations
    • Ai, J. Solid phase microextraction for quantitative analysis in non- equilibrium situations. Anal. Chem., 1997, 69, 1230-1236.
    • (1997) Anal. Chem. , vol.69 , pp. 1230-1236
    • Ai, J.1
  • 21
    • 0011195845 scopus 로고
    • Is my calibration linear?
    • Analytical Methods Committee
    • Analytical Methods Committee. Is my calibration linear? Analyst, 1994, 119, 2363-2366.
    • (1994) Analyst , vol.119 , pp. 2363-2366


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.