메뉴 건너뛰기




Volumn , Issue , 2009, Pages 3005-3009

Research on high-speed fuzzy reasoning with FPGA for fault diagnosis expert system

Author keywords

Expert system; Fault diagnosis; FPGA; Fuzzy reasoning

Indexed keywords

COMPLEX PROCESSES; DESIGN-EXPERT; DIAGNOSIS REASONING; FAULT DIAGNOSIS; FAULT DIAGNOSIS EXPERT SYSTEM; FPGA; FUNCTION TRANSFORM; FUZZY REASONING; HIGH-SPEED; LOGIC CONTROL; ON-LINE DIAGNOSIS; PROCESS COORDINATION; SINGLE-CHIP;

EID: 77449159991     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICMA.2009.5245988     Document Type: Conference Paper
Times cited : (12)

References (15)
  • 2
    • 33751094592 scopus 로고    scopus 로고
    • Fast Logic Reasoning of Fault Diagnosis Expert System with CPLD
    • Laijun Sun and Xiaoguang Hu, "Fast Logic Reasoning of Fault Diagnosis Expert System with CPLD," Electric Power Automation Equipment, vol. 26, no. 10, pp. 21-24, 2006.
    • (2006) Electric Power Automation Equipment , vol.26 , Issue.10 , pp. 21-24
    • Sun, L.1    Hu, X.2
  • 3
    • 33751085825 scopus 로고    scopus 로고
    • Design of 8-bits Bus Interface Based on CPLD
    • Fuzheng Xie and Shuxu Guo, "Design of 8-bits Bus Interface Based on CPLD," Modern Electronics Technique, vol. 6, no. 221, pp. 79-81, 2006.
    • (2006) Modern Electronics Technique , vol.6 , Issue.221 , pp. 79-81
    • Xie, F.1    Guo, S.2
  • 4
    • 33751093733 scopus 로고    scopus 로고
    • Designing SPI Interface based on CPLD
    • Yongtai He, "Designing SPI Interface based on CPLD," Computer Development &Applications, vol. 17, no. 10, pp. 27-28, 2004.
    • (2004) Computer Development &Applications , vol.17 , Issue.10 , pp. 27-28
    • He, Y.1
  • 5
    • 33750899096 scopus 로고    scopus 로고
    • Electric Dynamic Characteristics of Operating Mechanical for HV Circuit Breakers
    • Fengming Huo, Hongmei Su and J. Pan, "Electric Dynamic Characteristics of Operating Mechanical for HV Circuit Breakers," High Voltage Apparatus, vol. 37, no. 4, pp. 55-57, 2001.
    • (2001) High Voltage Apparatus , vol.37 , Issue.4 , pp. 55-57
    • Huo, F.1    Su, H.2    Pan, J.3
  • 6
    • 0031099793 scopus 로고    scopus 로고
    • Research on Mechanical Condition Monitoring for HV Circuit Breakers
    • L. Shen, Yulong Huang and Jiali Qian, "Research on Mechanical Condition Monitoring for HV Circuit Breakers," Proceeding of the CSEE, vol. 17, no. 2, pp. 113-117, 1997.
    • (1997) Proceeding of the CSEE , vol.17 , Issue.2 , pp. 113-117
    • Shen, L.1    Huang, Y.2    Qian, J.3
  • 7
    • 33750928379 scopus 로고    scopus 로고
    • Condition Assessment of Circuit Breakers Using a Trip Coil Profiling Approach
    • Dec
    • R. Henderson and D. Seeds, "Condition Assessment of Circuit Breakers Using a Trip Coil Profiling Approach," Monitors and Condition Assessment Equipment, pp. 811-813, Dec. 1996.
    • (1996) Monitors and Condition Assessment Equipment , pp. 811-813
    • Henderson, R.1    Seeds, D.2
  • 8
    • 0024479945 scopus 로고
    • On-line Monitoring and Diagnostic of Gas Circuit Breakers
    • K. Goto, T. Sakakibara, I. Kamata and S. Ikeda, "On-line Monitoring and Diagnostic of Gas Circuit Breakers," IEEE Trans. Power Delivery, vol. 4, no. 1, pp. 375-381, 1989.
    • (1989) IEEE Trans. Power Delivery , vol.4 , Issue.1 , pp. 375-381
    • Goto, K.1    Sakakibara, T.2    Kamata, I.3    Ikeda, S.4
  • 9
    • 0035683684 scopus 로고    scopus 로고
    • Bergman and W.J.B, Selecting Circuit Breaker Monitoring, Transmission and Distribution Conference and Exposition, 2, no. 28, pp. 1071-1076, 2001.
    • Bergman and W.J.B, "Selecting Circuit Breaker Monitoring," Transmission and Distribution Conference and Exposition, vol. 2, no. 28, pp. 1071-1076, 2001.
  • 10
    • 77449128066 scopus 로고    scopus 로고
    • IEEE Guide for the Selection of Monitoring for Circuit Breakers, IEEE Std C37.10.1-2000, 18 Apr. 2001.
    • IEEE Guide for the Selection of Monitoring for Circuit Breakers, IEEE Std C37.10.1-2000, 18 Apr. 2001.
  • 11
    • 33744720652 scopus 로고    scopus 로고
    • Mechanical Parameter Online Monitoring System for SF6 High Voltage Circuit Breakers
    • Changjun Wang, "Mechanical Parameter Online Monitoring System for SF6 High Voltage Circuit Breakers," Power System Technology, vol. 23, no. 7, pp. 34-37, 1999.
    • (1999) Power System Technology , vol.23 , Issue.7 , pp. 34-37
    • Wang, C.1
  • 12
    • 3042568632 scopus 로고    scopus 로고
    • Data Processing of On-line Mechanical Condition for Circuit Breakers
    • Yuee Yao, Ting Zhang and Zhangqi Wang, "Data Processing of On-line Mechanical Condition for Circuit Breakers," High Voltage Apparatus, vol. 40, no. 2, pp. 107-111, 2004.
    • (2004) High Voltage Apparatus , vol.40 , Issue.2 , pp. 107-111
    • Yao, Y.1    Zhang, T.2    Wang, Z.3
  • 13
    • 33751092218 scopus 로고    scopus 로고
    • A Research of an On-line Monitoring System for HV Circuit Breaker
    • Jan
    • Xiaoguang Hu and Fang Wang, "A Research of an On-line Monitoring System for HV Circuit Breaker," Electrotechnical Journal, pp. 36-38, Jan. 2003.
    • (2003) Electrotechnical Journal , pp. 36-38
    • Hu, X.1    Wang, F.2
  • 15
    • 33751082029 scopus 로고    scopus 로고
    • On-line Condition Monitoring and Diagnosis for High Voltage Circuit Breakers
    • Quanzhi Liu, Mingyi Shi and Zhangqi Wang, "On-line Condition Monitoring and Diagnosis for High Voltage Circuit Breakers," High Voltage Technology, vol. 27, no. 5, pp. 29-31, 2001.
    • (2001) High Voltage Technology , vol.27 , Issue.5 , pp. 29-31
    • Liu, Q.1    Shi, M.2    Wang, Z.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.