메뉴 건너뛰기




Volumn 15, Issue 1, 2010, Pages 74-78

Investigation of Sparse Data Mouse Imaging Using Micro-CT with a Carbon-Nanotube-Based X-ray Source

Author keywords

compressed sensing; computed tomography; image reconstruction; TV minimization

Indexed keywords

A-CARBON; ALGORITHM DEVELOPMENT; COMPRESSED SENSING; COMPUTED TOMOGRAPHY; CONE BEAM; CONVENTIONAL ALGORITHMS; CT IMAGING; CT SCANNERS; DYNAMIC IMAGING; ELECTRONIC CONTROLS; GATED IMAGING; IMAGING DOSE; IMAGING TASK; INCOMPLETE DATA; MEASURED DATA; MICRO CT; MINIMIZATION ALGORITHMS; MOUSE IMAGING; SPARSE DATA; SUBSTANTIAL REDUCTION; TEMPORAL RESOLUTION; TOTAL-VARIATION; X-RAY SOURCES;

EID: 77449091209     PISSN: 10070214     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1007-0214(10)70012-2     Document Type: Article
Times cited : (7)

References (19)
  • 1
    • 0019361169 scopus 로고
    • Fast minimum variance estimator for limited angle CT image reconstruction
    • Buonocore M.H., Brody W.R., and Macovski A. Fast minimum variance estimator for limited angle CT image reconstruction. Medical Physics 8 5 (1981) 695-702
    • (1981) Medical Physics , vol.8 , Issue.5 , pp. 695-702
    • Buonocore, M.H.1    Brody, W.R.2    Macovski, A.3
  • 3
    • 0034857331 scopus 로고    scopus 로고
    • On few-view tomographic reconstruction with megavoltage photon beams
    • Loose S., and Leszczynski K.W. On few-view tomographic reconstruction with megavoltage photon beams. Medical Physics 28 8 (2001) 1679-1688
    • (2001) Medical Physics , vol.28 , Issue.8 , pp. 1679-1688
    • Loose, S.1    Leszczynski, K.W.2
  • 4
    • 0037036596 scopus 로고    scopus 로고
    • An accurate iterative reconstruction algorithm for sparse objects: application to 3D blood vessel reconstruction from a limited number of projections
    • Li M., Yang H., and Kudo H. An accurate iterative reconstruction algorithm for sparse objects: application to 3D blood vessel reconstruction from a limited number of projections. Physics in Medicine and Biology 47 (2002) 2599-2609
    • (2002) Physics in Medicine and Biology , vol.47 , pp. 2599-2609
    • Li, M.1    Yang, H.2    Kudo, H.3
  • 5
    • 49749137392 scopus 로고    scopus 로고
    • Image reconstruction from a small number of projections
    • 045001
    • Herman G.T., and Davidi R. Image reconstruction from a small number of projections. Inverse Problems 24 (2008) 045001
    • (2008) Inverse Problems , vol.24
    • Herman, G.T.1    Davidi, R.2
  • 6
    • 29144491203 scopus 로고    scopus 로고
    • Technical Report, Stanford University, USA
    • Donoho D L. Compressed sensing. Technical Report, Stanford University, USA, 2004.
    • (2004) Compressed sensing
    • Donoho, D.L.1
  • 7
    • 31744440684 scopus 로고    scopus 로고
    • Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information
    • Candes E., Romberg J., and Tao T. Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information. IEEE Transactions on Information Theory 52 (2006) 489-509
    • (2006) IEEE Transactions on Information Theory , vol.52 , pp. 489-509
    • Candes, E.1    Romberg, J.2    Tao, T.3
  • 8
    • 33745162201 scopus 로고    scopus 로고
    • Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT
    • Sidky E.Y., Kao K.M., and Pan X. Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT. Journal of X-Ray Science and Technology 14 (2006) 119-139
    • (2006) Journal of X-Ray Science and Technology , vol.14 , pp. 119-139
    • Sidky, E.Y.1    Kao, K.M.2    Pan, X.3
  • 9
    • 51849124226 scopus 로고    scopus 로고
    • Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization
    • Sidky E.Y., and Pan X. Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization. Physics in Medicine and Biology 53 (2008) 4777-4807
    • (2008) Physics in Medicine and Biology , vol.53 , pp. 4777-4807
    • Sidky, E.Y.1    Pan, X.2
  • 10
    • 70350645492 scopus 로고    scopus 로고
    • Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithms
    • Tang J., Nett B.E., and Chen G.H. Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithms. Physics in Medicine and Biology 54 (2009) 5781-5804
    • (2009) Physics in Medicine and Biology , vol.54 , pp. 5781-5804
    • Tang, J.1    Nett, B.E.2    Chen, G.H.3
  • 11
    • 79956044491 scopus 로고    scopus 로고
    • Generation of continuous and pulsed diagnostic imaging X-ray radiation using a carbon-nanotube-based field-emission cathode
    • Yue G., Qiu Q., Gao B., et al. Generation of continuous and pulsed diagnostic imaging X-ray radiation using a carbon-nanotube-based field-emission cathode. Applied Physics Letters 81 (2002) 355-357
    • (2002) Applied Physics Letters , vol.81 , pp. 355-357
    • Yue, G.1    Qiu, Q.2    Gao, B.3
  • 12
    • 33748517225 scopus 로고    scopus 로고
    • Carbon nanotube based microfocus field emission X-ray source for microcomputed tomography
    • Liu Z., Guang Y., Lee Y.Z., et al. Carbon nanotube based microfocus field emission X-ray source for microcomputed tomography. Applied Physics Letters 89 (2006) 103111
    • (2006) Applied Physics Letters , vol.89 , pp. 103111
    • Liu, Z.1    Guang, Y.2    Lee, Y.Z.3
  • 13
    • 20844438487 scopus 로고    scopus 로고
    • Stationary scanning X-ray source based on carbon nanotube field emitters
    • Zhang J., Yang G., Cheng Y., et al. Stationary scanning X-ray source based on carbon nanotube field emitters. Applied Physics Letters 86 (2005) 184104
    • (2005) Applied Physics Letters , vol.86 , pp. 184104
    • Zhang, J.1    Yang, G.2    Cheng, Y.3
  • 19
    • 70350718948 scopus 로고    scopus 로고
    • Enhanced imaging of microcalcifications in digital breast tomosynthesis through improved image-reconstruction algorithms
    • Sidky E.Y., Pan X., Reiser I.S., et al. Enhanced imaging of microcalcifications in digital breast tomosynthesis through improved image-reconstruction algorithms. Medical Physics 36 11 (2009) 4920-4932
    • (2009) Medical Physics , vol.36 , Issue.11 , pp. 4920-4932
    • Sidky, E.Y.1    Pan, X.2    Reiser, I.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.