메뉴 건너뛰기




Volumn 26, Issue 12, 2009, Pages 1090-1091

Can't intubate, can't ventilate: Rescue airway sing a size 21/2 laryngeal mask airway in morbidly obese female patient

Author keywords

[No Author keywords available]

Indexed keywords

SEVOFLURANE;

EID: 77449085504     PISSN: 02650215     EISSN: 13652346     Source Type: Journal    
DOI: 10.1097/EJA.0b013e32832a2273     Document Type: Letter
Times cited : (4)

References (7)
  • 1
    • 38449090993 scopus 로고    scopus 로고
    • Remifentanil target-controlled infusion vs propofol target-controlled infusion for conscious sedation for awake fibreoptic intubation: A double-blinded randomized controlled trial
    • Rai M, Parry T, Dombrovskis A, et al. Remifentanil target-controlled infusion vs propofol target-controlled infusion for conscious sedation for awake fibreoptic intubation: a double-blinded randomized controlled trial. Br J Anaesth 2008; 100: 125-130.
    • (2008) Br J Anaesth , vol.100 , pp. 125-130
    • Rai, M.1    Parry, T.2    Dombrovskis, A.3
  • 2
    • 0031040567 scopus 로고    scopus 로고
    • Learning curves for fibreoptic nasotracheal intubation when using the endoscopic video camera
    • Smith J, Jackson A, Hurdley J, et al. Learning curves for fibreoptic nasotracheal intubation when using the endoscopic video camera. Anaesthesia 1997; 52: 101-106.
    • (1997) Anaesthesia , vol.52 , pp. 101-106
    • Smith, J.1    Jackson, A.2    Hurdley, J.3
  • 3
    • 0042242891 scopus 로고    scopus 로고
    • Structure and process quality illustrated by fibreoptic intubation: Analysis of 1612 cases
    • Heidegger T, Gerig H, Ulrich B, et al. Structure and process quality illustrated by fibreoptic intubation: analysis of 1612 cases. Anaesthesia 2003; 58: 734-739.
    • (2003) Anaesthesia , vol.58 , pp. 734-739
    • Heidegger, T.1    Gerig, H.2    Ulrich, B.3
  • 4
    • 23844536471 scopus 로고    scopus 로고
    • Use of the Aintree intubation catheter in a patient with an unexpected difficult airway
    • Zura A, Doyle D, Orlandi M. Use of the Aintree intubation catheter in a patient with an unexpected difficult airway. Can J Anesth 2005; 52: 646-649.
    • (2005) Can J Anesth , vol.52 , pp. 646-649
    • Zura, A.1    Doyle, D.2    Orlandi, M.3
  • 5
    • 33646781609 scopus 로고    scopus 로고
    • Sucessful reintubation after cervical spine exposure using an Aintree intubation catheter and a laryngeal mask airway
    • Avitsian R, Doyle D, Helfand R, et al. Sucessful reintubation after cervical spine exposure using an Aintree intubation catheter and a laryngeal mask airway. J Clin Anesth 2006; 18: 224-225.
    • (2006) J Clin Anesth , vol.18 , pp. 224-225
    • Avitsian, R.1    Doyle, D.2    Helfand, R.3
  • 6
    • 33846213885 scopus 로고    scopus 로고
    • Nonconventional uses of the Aintree intubating catheter in management of the difficult airway
    • Cook T, Seller C, Gupta K, et al. Nonconventional uses of the Aintree intubating catheter in management of the difficult airway. Anaesthesia 2007; 62: 169-174.
    • (2007) Anaesthesia , vol.62 , pp. 169-174
    • Cook, T.1    Seller, C.2    Gupta, K.3
  • 7
    • 23944464466 scopus 로고    scopus 로고
    • Low-skill fibreoptic intubation: Use of the Aintree Catheter with the classic LMA
    • Higgs A, Clark E, Premraj K. Low-skill fibreoptic intubation: use of the Aintree Catheter with the classic LMA. Anaesthesia 2005; 60: 915-920.
    • (2005) Anaesthesia , vol.60 , pp. 915-920
    • Higgs, A.1    Clark, E.2    Premraj, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.