메뉴 건너뛰기




Volumn 26, Issue 13, 2004, Pages 1939-1956

Influence of damping systems on building structures subject to seismic effects

Author keywords

Acceleration; Displacement; Earthquake; Finite element analysis; Friction damper; Viscoelastic damper

Indexed keywords

CIVIL ENGINEERING; CONCRETE CONSTRUCTION; EARTHQUAKES; FRICTION; MATHEMATICAL MODELS; PARAMETER ESTIMATION; STIFFNESS; VISCOELASTICITY;

EID: 7744231445     PISSN: 01410296     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.engstruct.2004.07.008     Document Type: Article
Times cited : (56)

References (11)
  • 1
    • 0003588248 scopus 로고
    • A methodology for design of viscoelastic dampers in earthquake-resistant structures
    • Technical report UCB/EERC-93/09, Earthquake Engineering Research Center, University of California, Berkeley
    • Abbas H, Kelly JM. A methodology for design of viscoelastic dampers in earthquake-resistant structures. Technical report UCB/EERC-93/09, Earthquake Engineering Research Center, University of California, Berkeley, 1993.
    • (1993)
    • Abbas, H.1    Kelly, J.M.2
  • 2
    • 0033082898 scopus 로고    scopus 로고
    • Optimal placement of DVFC controllers on buildings subjected to earthquake loading
    • Abdullah M. Optimal placement of DVFC controllers on buildings subjected to earthquake loading Earthquake Eng Struct Dyn 28 1999 127-141
    • (1999) Earthquake Eng. Struct. Dyn. , vol.28 , pp. 127-141
    • Abdullah, M.1
  • 4
    • 0013096292 scopus 로고
    • Seismic response of a 2/5 scale steel structure with added viscoelastic dampers
    • Technical report NCEER-91-0012. State University of New York, Buffalo, NY
    • Chang KC, Soong TT, Oh ST, Lai ML. Seismic response of a 2/5 scale steel structure with added viscoelastic dampers. Technical report NCEER-91-0012. State University of New York, Buffalo, NY, 1991.
    • (1991)
    • Chang, K.C.1    Soong, T.T.2    Oh, S.T.3    Lai, M.L.4
  • 5
    • 0003445464 scopus 로고    scopus 로고
    • Passive energy dissipation systems for structural design and retrofit
    • Monograph No. 1, Multidisciplinary Center for Earthquake Engineering Research, State University of New York, Buffalo, NY
    • Constantinou MC, Soong TT, Dargush GF. Passive energy dissipation systems for structural design and retrofit. Monograph No. 1, Multidisciplinary Center for Earthquake Engineering Research, State University of New York, Buffalo, NY, 1998.
    • (1998)
    • Constantinou, M.C.1    Soong, T.T.2    Dargush, G.F.3
  • 7
    • 0013095914 scopus 로고    scopus 로고
    • The application example of the hybrid damping system combined the hysteretic damper with viscous damper to high-rise building
    • Sydney, Australia
    • Hisano K. Kuribayashi H. Saitou K. The application example of the hybrid damping system combined the hysteretic damper with viscous damper to high-rise building Proceedings of the 5th International Conference on Motion and Vibration Control, Sydney, Australia vol. 1 2000 451-456
    • (2000) Proceedings of the 5th International Conference on Motion and Vibration Control , vol.1 , pp. 451-456
    • Hisano, K.1    Kuribayashi, H.2    Saitou, K.3
  • 8
    • 0013092016 scopus 로고    scopus 로고
    • Improving the seismic response of structures by the use of dampers in shear walls
    • ME thesis, School of Civil Engineering, Queensland University of Technology, Brisbane, Australia
    • Madsen LPB. Improving the seismic response of structures by the use of dampers in shear walls. ME thesis, School of Civil Engineering, Queensland University of Technology, Brisbane, Australia, 2001.
    • (2001)
    • Madsen, L.P.B.1
  • 9
    • 0042327601 scopus 로고    scopus 로고
    • Passive energy dissipation devices for seismic applications
    • Technical report NISTIR 5923. Institute of Standards and Technology, Gaithersburg, MD, 20899, November
    • Sadek F, Mohraz B, Taylor WA, Chung RM. Passive energy dissipation devices for seismic applications. Technical report NISTIR 5923. Building and Fire Research Laboratory, National Institute of Standards and Technology, Gaithersburg, MD, 20899, November 1996.
    • (1996) Building and Fire Research Laboratory National
    • Sadek, F.1    Mohraz, B.2    Taylor, W.A.3    Chung, R.M.4
  • 10
    • 7744237945 scopus 로고    scopus 로고
    • Viscous damper versus friction damper for retrofit of a non-ductile reinforced concrete building with unreinforced masonry infill
    • SEAOC 1999 Convention
    • Shao D, Miyamoto HK. Viscous damper versus friction damper for retrofit of a non-ductile reinforced concrete building with unreinforced masonry infill. SEAOC 1999 Convention.
    • Shao, D.1    Miyamoto, H.K.2
  • 11
    • 84908144695 scopus 로고
    • The use of fast Fourier transform for the estimation of power spectra: A method based on time averaging over short modified periodograms
    • AU-15
    • Welch P.D. The use of fast Fourier transform for the estimation of power spectra: A method based on time averaging over short modified periodograms IEEE Trans Audio Electroacoust AU-15 1967 70-73
    • (1967) IEEE Trans Audio Electroacoust , pp. 70-73
    • Welch, P.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.