Volumn 35, Issue 7, 2010, Pages 1403-1407

The influence of a vertical ground heat exchanger length on the electricity consumption of the heat pumps

Author keywords

Energy analysis tool; Ground heat exchanger length; Ground source heat pump

Indexed keywords

ANALYTICAL SIMULATIONS; CHARACTERISTIC CURVE; COEFFICIENT OF PERFORMANCE; COOLING LOAD; DESIGN METHOD; ELECTRICITY-CONSUMPTION; ENERGY ANALYSIS; GROUND HEAT EXCHANGERS; GROUND SOURCE HEAT PUMP; HEAT PUMPS; HEATING AND COOLING OF BUILDINGS; INPUT PARAMETER; INSTALLATION COSTS; PROCESS EQUIPMENTS; SIMULATION ALGORITHMS; THERMO-PHYSICAL PROPERTY; TIME PERIODS;

EID: 77349122792     PISSN: 09601481     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.renene.2009.11.009     Document Type: Article
Times cited : (20)

References (19)
  • 1
    • 77349120847 scopus 로고    scopus 로고
    • Lund WJ. Present utilization and future prospects of geothermal energy worldwide. In: Proceedings of the Renewable Energy 2006 Conference. Makuhari Messe: Chiba, Japan; 2006.
    • Lund WJ. Present utilization and future prospects of geothermal energy worldwide. In: Proceedings of the Renewable Energy 2006 Conference. Makuhari Messe: Chiba, Japan; 2006.
  • 3
    • 77349094384 scopus 로고    scopus 로고
    • Andritsos N, Dalampakis P, Karydakis G, Kolios N, Fytikas M. Update and characteristics of low-enthalpy geothermal applications in Greece. In: proceedings of European Geothermal Congress EGC 2007, May 30-June 1, Unterhaching, Germany; 2007.
    • Andritsos N, Dalampakis P, Karydakis G, Kolios N, Fytikas M. Update and characteristics of low-enthalpy geothermal applications in Greece. In: proceedings of European Geothermal Congress EGC 2007, May 30-June 1, Unterhaching, Germany; 2007.
  • 4
    • 77349101405 scopus 로고    scopus 로고
    • Personal communication;
    • Andritsos N. Personal communication; 2008.
    • (2008)
    • Andritsos, N.1
  • 11
    • 77349104711 scopus 로고    scopus 로고
    • Michopoulos A. Theoretical and experimental approach of ground heat exchanger. In: PhD thesis, Department of Mechanical Engineering, Aristotle University of Thessaloniki, Greece; 2008 [in Greek].
    • Michopoulos A. Theoretical and experimental approach of ground heat exchanger. In: PhD thesis, Department of Mechanical Engineering, Aristotle University of Thessaloniki, Greece; 2008 [in Greek].
  • 15
    • 0003619510 scopus 로고
    • Ground heat storage thermal analyses of duct storage systems, I
    • PhD thesis. Department of Mathematical Physics, University of Lund, Sweden;
    • Hellström G. Ground heat storage thermal analyses of duct storage systems, I. In: Theory, PhD thesis. Department of Mathematical Physics, University of Lund, Sweden; 1991.
    • (1991) Theory
    • Hellström, G.1
  • 17
    • 33846473699 scopus 로고    scopus 로고
    • Three-years operation experience of a ground source heat pump system in Northern Greece
    • Michopoulos A., Bozis D., Kikidis P., Papakostas K., and Kyriakis N.A. Three-years operation experience of a ground source heat pump system in Northern Greece. Energy and Buildings 39 (2007) 328-334
    • (2007) Energy and Buildings , vol.39 , pp. 328-334
    • Michopoulos, A.1    Bozis, D.2    Kikidis, P.3    Papakostas, K.4    Kyriakis, N.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.