Volumn 1273, Issue C, 2004, Pages 162-166

Soft failures with cochlear implants

Author keywords

Cochlear implant; Cochlear implant device analysis; Soft failure

Indexed keywords


EID: 77249108807     PISSN: 05315131     EISSN: None     Source Type: Book Series    
DOI: 10.1016/j.ics.2004.07.028     Document Type: Article
Times cited : (1)

References (7)
  • 1
    • 0029154154 scopus 로고
    • Averaged electrode voltages: management of electrode failures in children, fluctuating threshold and comfort levels, and otosclerosis
    • L.H. Mens J.P. Brokx P. van den Broek Averaged electrode voltages: management of electrode failures in children, fluctuating threshold and comfort levels, and otosclerosis Annals of Otology, Rhinology & Laryngology. Supplement 166 1995 169 172
    • (1995) Annals of Otology, Rhinology & Laryngology. Supplement , vol.166 , pp. 169-172
    • Mens, L.H.1    Brokx, J.P.2    van den Broek, P.3
  • 2
    • 0036226310 scopus 로고    scopus 로고
    • Averaged electrode voltages in users of the Clarion cochlear implant device
    • L.H. Mens J.J. Mulder Averaged electrode voltages in users of the Clarion cochlear implant device Annals of Otology, Rhinology & Laryngology 111 2002 370 375
    • (2002) Annals of Otology, Rhinology & Laryngology , vol.111 , pp. 370-375
    • Mens, L.H.1    Mulder, J.J.2
  • 3
    • 0027715603 scopus 로고
    • Implant generated surface potentials and (partial) device failures of the Nucleus cochlear implant
    • L.H. Mens T. Oostendorp P. van den Broek Implant generated surface potentials and (partial) device failures of the Nucleus cochlear implant Advances in Oto-Rhino-Laryngology 48 1993 75 78
    • (1993) Advances in Oto-Rhino-Laryngology , vol.48 , pp. 75-78
    • Mens, L.H.1    Oostendorp, T.2    van den Broek, P.3
  • 4
    • 0028136638 scopus 로고
    • Identifying electrode failures with cochlear implant generated surface potentials
    • L.H. Mens T. Oostendorp P. van den Broek Identifying electrode failures with cochlear implant generated surface potentials Ear and Hearing 15 1994 330 338
    • (1994) Ear and Hearing , vol.15 , pp. 330-338
    • Mens, L.H.1    Oostendorp, T.2    van den Broek, P.3
  • 5
    • 0029298222 scopus 로고
    • Averaged electrode voltages used to identify nonfunctioning electrodes in cochlear implants: case study
    • A.M. Peterson R.H. Brey G.W. Facer Averaged electrode voltages used to identify nonfunctioning electrodes in cochlear implants: case study Journal of the American Academy of Audiology 6 1995 243 249
    • (1995) Journal of the American Academy of Audiology , vol.6 , pp. 243-249
    • Peterson, A.M.1    Brey, R.H.2    Facer, G.W.3
  • 7
    • 85120196473 scopus 로고    scopus 로고
    • K. Franck, U. Shah, Averaged electrode voltage to diagnose an unusual cochlear implant internal device failure, J. Am. Acad. Audio (in press).


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.