메뉴 건너뛰기




Volumn 17, Issue 1, 2010, Pages 63-70

Positive corona inception voltages and corona currents for air at various pressures and humidities

Author keywords

Corona current; Corona inception voltage; Humidity; Positive corona; Pressure

Indexed keywords

AIR DENSITY; AIR PRESSURES; APPLIED DC-VOLTAGE; APPLIED VOLTAGES; CALCULATION METHODS; COEFFICIENT C; CORONA CHARACTERISTIC; CORONA CURRENTS; CORONA INCEPTION VOLTAGE; DRY AIR; ELECTRODE SYSTEMS; EXPERIMENTAL DETERMINATION; HUMID AIR; HUMIDITY; IONIZATION COEFFICIENT; LINEAR INTERPOLATION; METHOD OF CALCULATION; PARTICLE-IN-CELL; POSITIVE CORONA; SPACE CHARGE DENSITY;

EID: 77249102123     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2010.5412003     Document Type: Article
Times cited : (93)

References (29)
  • 3
    • 0025460659 scopus 로고
    • Inception of corona and rate of rise of voltage in diverging electric fields
    • M. Abdel-Salam and N.L. Allen, "Inception of corona and rate of rise of voltage in diverging electric fields", IEE Proc.-A, Vol.137, pp. 217-220, 1990.
    • (1990) IEE Proc.-A , vol.137 , pp. 217-220
    • Abdel-Salam, M.1    Allen, N.L.2
  • 4
    • 0242657881 scopus 로고    scopus 로고
    • Onset corona fields and electrical breakdown criteria
    • J.J. Lowke and F.D. Alessandro, "Onset corona fields and electrical breakdown criteria", J. Phys. D: Appl. Phys., Vol.36, pp. 2673-2682, 2003.
    • (2003) J. Phys. D: Appl. Phys. , vol.36 , pp. 2673-2682
    • Lowke, J.J.1    Alessandro, F.D.2
  • 5
    • 0021517811 scopus 로고
    • Theoretical evaluation of Peek's law
    • G. Hartmann, "Theoretical evaluation of Peek's law", IEEE Trans. Indus. Appl., Vol.20, pp. 1647-1651, 1984.
    • (1984) IEEE Trans. Indus. Appl. , vol.20 , pp. 1647-1651
    • Hartmann, G.1
  • 6
    • 26244439101 scopus 로고    scopus 로고
    • Onset voltage of positive glow corona in rod-plane gaps as influenced by temperature
    • M. Abdel-Salam and N.L. Allen, "Onset voltage of positive glow corona in rod-plane gaps as influenced by temperature", IEE Proc. Sci. Meas. Technol, Vol.152, pp. 227-232, 2005.
    • (2005) IEE Proc. Sci. Meas. Technol , vol.152 , pp. 227-232
    • Abdel-Salam, M.1    Allen, N.L.2
  • 7
    • 0242657881 scopus 로고    scopus 로고
    • Onset corona fields and electrical breakdown criteria
    • J. J. Lowke and F. D'Alessandro, "Onset corona fields and electrical breakdown criteria", J. Phys. D: Appl. Phys., Vol.28, pp. 2673-2682, 2003.
    • (2003) J. Phys. D: Appl. Phys. , vol.28 , pp. 2673-2682
    • Lowke, J.J.1    D'Alessandro, F.2
  • 8
    • 6344243612 scopus 로고    scopus 로고
    • Application of a corona onset criterion to calculation of corona onset voltage of stranded conductors
    • K. Yamazaki and R.G. Olsen., "Application of a corona onset criterion to calculation of corona onset voltage of stranded conductors", IEEE Trans. Dielectr. Electr. Insul., Vol.11,pp.674-680,2004.
    • (2004) IEEE Trans. Dielectr. Electr. Insul. , vol.11 , pp. 674-680
    • Yamazaki, K.1    Olsen, R.G.2
  • 9
    • 0025899754 scopus 로고
    • Positive dc corona and sparkover in short and long rod-plane gaps under variable humidity conditions
    • M. Boutlendj, N.L. Allen and H.A. Lightfoot, "Positive dc corona and sparkover in short and long rod-plane gaps under variable humidity conditions", IEE Proc.-A, Vol.138, pp.31-36, 1991.
    • (1991) IEE Proc.-A , vol.138 , pp. 31-36
    • Boutlendj, M.1    Allen, N.L.2    Lightfoot, H.A.3
  • 11
    • 0034479953 scopus 로고    scopus 로고
    • Negative corona in air using a point/cup electrode system
    • E.N. Li and J.M.K. MacAlpine, "Negative corona in air using a point/cup electrode system", IEEE Trans. Dielectr. Electr. Insul., Vol.7, pp.752- 757,2000.
    • (2000) IEEE Trans. Dielectr. Electr. Insul. , vol.7 , pp. 752-757
    • Li, E.N.1    MacAlpine, J.M.K.2
  • 12
    • 0038408576 scopus 로고    scopus 로고
    • Positive corona in air using a point/cup electrode system
    • J.M.K. MacAlpine and E.N. Li, "Positive corona in air using a point/cup electrode system", IEEE Trans. Dielectr. Electr. Insul., Vol.10,pp.307-311, 2003.
    • (2003) IEEE Trans. Dielectr. Electr. Insul. , vol.10 , pp. 307-311
    • MacAlpine, J.M.K.1    Li, E.N.2
  • 13
    • 0001180613 scopus 로고
    • A computer model for streamer propagation
    • I. Gallimberti, "A computer model for streamer propagation", J. Phys. D: Appl. Phys., Vol.5, pp. 2179-2189, 1972.
    • (1972) J. Phys. D: Appl. Phys. , vol.5 , pp. 2179-2189
    • Gallimberti, I.1
  • 14
    • 0016973011 scopus 로고
    • Dependence of positive corona streamer propagation on air pressure and water vapor content
    • C. T. Phelps and R. F. Griffiths, "Dependence of positive corona streamer propagation on air pressure and water vapor content", J. Appl. Phys., Vol.47, pp. 2929-2934, 1976.
    • (1976) J. Appl. Phys. , vol.47 , pp. 2929-2934
    • Phelps, C.T.1    Griffiths, R.F.2
  • 15
    • 0038725727 scopus 로고    scopus 로고
    • Current-voltage characteristics of corona in rod-plane gaps as influenced by temperature
    • M. Abdel-Salam and N.L. Allen, "Current-voltage characteristics of corona in rod-plane gaps as influenced by temperature", IEE Proc. Sci. Meas. Technol.,Vol. 150, pp. 135-139, 2003.
    • (2003) IEE Proc. Sci. Meas. Technol. , vol.150 , pp. 135-139
    • Abdel-Salam, M.1    Allen, N.L.2
  • 17
    • 0038603372 scopus 로고
    • Calculating the effect of high temperature on the onset voltage of negative discharges
    • M. Abdel-Salam, "Calculating the effect of high temperature on the onset voltage of negative discharges", J. Phys. D: Appl. Phys., Vol.9, pp.149- 154, 1976.
    • (1976) J. Phys. D: Appl. Phys. , vol.9 , pp. 149-154
    • Abdel-Salam, M.1
  • 18
    • 0036754371 scopus 로고    scopus 로고
    • Corona power loss, electric field, and current density profiles in bundled horizontal and vertical bipolar conductors
    • Z.M. Al-Hamouz, "Corona power loss,electric field,and current density profiles in bundled horizontal and vertical bipolar conductors", IEEE Trans. Indus. Appl.,Vol. 38, pp. 1182-1189, 2002.
    • (2002) IEEE Trans. Indus. Appl. , vol.38 , pp. 1182-1189
    • Al-Hamouz, Z.M.1
  • 19
    • 0014509536 scopus 로고
    • Analysis of corona losses on DC transmission lines part I: Unipolar lines
    • M.P. Sarma, "Analysis of corona losses on DC transmission lines part I: unipolar lines", IEEE Tran. Power Appar. Syst., Vol.88, pp. 718-731, 1969.
    • (1969) IEEE Tran. Power Appar. Syst. , vol.88 , pp. 718-731
    • Sarma, M.P.1
  • 20
    • 0023829428 scopus 로고
    • Accurate calculation of ion flow field under HVDC bipolar transmission lines
    • B.L. Qin, J.N. Sheng and Z. Yan, "Accurate calculation of ion flow field under HVDC bipolar transmission lines", IEEE Trans. Power. Del., Vol.3, pp.368-376, 1988.
    • (1988) IEEE Trans. Power. Del. , vol.3 , pp. 368-376
    • Qin, B.L.1    Sheng, J.N.2    Yan, Z.3
  • 22
    • 0022112107 scopus 로고
    • Application of integral equations to solving inverse problems of stationary electromagnetic fields
    • K. Adamiak, "Application of integral equations to solving inverse problems of stationary electromagnetic fields", Intern. J. Numer. Meth, Vol.21, pp.1447-1458, 1985.
    • (1985) Intern. J. Numer. Meth , vol.21 , pp. 1447-1458
    • Adamiak, K.1
  • 23
    • 4944258001 scopus 로고    scopus 로고
    • Simulation of corona discharge in point-plane configuration
    • DOI 10.1016/j.elstat.2004.01.021, PII S030438860400035X
    • K. Adamiak and P. Atten, "Simulation of corona discharge in point-plane configuration", J. Electr., Vol.61, pp. 85-98, 2004. (Pubitemid 38503382)
    • (2004) Journal of Electrostatics , vol.61 , Issue.2 , pp. 85-98
    • Adamiak, K.1    Atten, P.2
  • 25
  • 26
    • 0021855742 scopus 로고
    • Positive wire-to-plane corona as influenced by atmospheric humidity
    • M. Abdel-Salam, "Positive wire-to-plane corona as influenced by atmospheric humidity", IEEE Trans. Indus. Appl., Vol.21, pp. 35- 40,1985.
    • (1985) IEEE Trans. Indus. Appl. , vol.21 , pp. 35-40
    • Abdel-Salam, M.1
  • 27
    • 0023961006 scopus 로고
    • Boundary conditions for the positive direct-current corona in a coaxial system
    • J.E. Jones, J. Dupuy and G.O.S. Schreiber, ''Boundary conditions for the positive direct-current corona in a coaxial system", J. Phys. D: Appl. Phys., Vol. 21, pp. 322-333, 1988.
    • (1988) J. Phys. D: Appl. Phys. , vol.21 , pp. 322-333
    • Jones, J.E.1    Dupuy, J.2    Schreiber, G.O.S.3
  • 28
    • 42149114030 scopus 로고    scopus 로고
    • Variation of the dynamics of positive streamer with pressure and humidity in air
    • J.F. Hui, Z.C. Guan, L.M. Wang and Q.W. Li, "Variation of the Dynamics of Positive Streamer with Pressure and Humidity in Air", IEEE Trans. Dielectr. Electr. Insul., Vol.15,pp.382-388, 2008.
    • (2008) IEEE Trans. Dielectr. Electr. Insul. , vol.15 , pp. 382-388
    • Hui, J.F.1    Guan, Z.C.2    Wang, L.M.3    Li, Q.W.4
  • 29
    • 33646355690 scopus 로고    scopus 로고
    • On photoionization produced by discharges in air
    • G.V. Naidis, "On photoionization produced by discharges in air ", Plasma Sources Sci. Tech., Vol.15, pp. 253-255, 2006.
    • (2006) Plasma Sources Sci. Tech. , vol.15 , pp. 253-255
    • Naidis, G.V.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.