메뉴 건너뛰기




Volumn 24, Issue 1, 2010, Pages 392-395

Calculating flash point numbers from molecular structure: An improved method for predicting the flash points of acyclic alkanes

Author keywords

[No Author keywords available]

Indexed keywords

ACYCLIC ALKANES; AVERAGE ABSOLUTE DEVIATION; BRANCHED ALKANES; DATA SETS; FLASH POINTS; IMPROVED METHODS; NOVEL METHODS;

EID: 77149173756     PISSN: 08870624     EISSN: 15205029     Source Type: Journal    
DOI: 10.1021/ef900883u     Document Type: Conference Paper
Times cited : (18)

References (32)
  • 9
    • 77149171867 scopus 로고    scopus 로고
    • A listing of the compounds and their literature flash points is provided in the Supporting Information
    • A listing of the compounds and their literature flash points is provided in the Supporting Information.
  • 13
    • 77149180573 scopus 로고    scopus 로고
    • Equation 4 as given here is the correct form of the equation. It reproduces the values reported in ref 11 and was used in ref 5b
    • Equation 4 as given here is the correct form of the equation. It reproduces the values reported in ref 11 and was used in ref 5b.
  • 16
    • 33750162478 scopus 로고    scopus 로고
    • The AAD reported for this method with a different data set was 3.2 K
    • Vazhev, V. V.; Aldabergenov, M. K.; Vazheva, N. V. Pet. Chem. 2006, 46, 136. TheAADreported for this method with a different data set was 3.2 K.
    • (2006) Pet. Chem. , vol.46 , pp. 136
    • Vazhev, V.V.1    Aldabergenov, M.K.2    Vazheva, N.V.3
  • 28
    • 77149127852 scopus 로고    scopus 로고
    • Our data set did not include compounds with propyl or larger substituents, so parameters for such groups are not included in eqs 6 or ref 10. In the event flash points for compounds with such substituents are needed, they may be predicted with eq 9 and either experimental boiling points or values estimated by any of a number of the boiling point estimation methods discussed in ref 22
    • Our data set did not include compounds with propyl or larger substituents, so parameters for such groups are not included in eqs 6 or ref 10. In the event flash points for compounds with such substituents are needed, they may be predicted with eq 9 and either experimental boiling points or values estimated by any of a number of the boiling point estimation methods discussed in ref 22.
  • 29
    • 77149135874 scopus 로고    scopus 로고
    • BP values on branching
    • BP values on branching.
  • 30
    • 77149147883 scopus 로고    scopus 로고
    • 2=0.9899), and the coefficients for these parameters were not statistically significant
    • 2=0.9899), and the coefficients for these parameters were not statistically significant.
  • 31
    • 77149123447 scopus 로고    scopus 로고
    • A reviewer noted that even replicates of flash points determined by the same standard method can show uncertainties of 2Kor more. We are grateful to the reviewer for suggesting that we discuss the inherent uncertainties of flash point data
    • A reviewer noted that even replicates of flash points determined by the same standard method can show uncertainties of 2Kor more. We are grateful to the reviewer for suggesting that we discuss the inherent uncertainties of flash point data.
  • 32
    • 77149123770 scopus 로고    scopus 로고
    • This additivity is explicit in eq 10 and is implicit in eq 9 because YBP values vary with structure as shown in eq 6
    • This additivity is explicit in eq 10 and is implicit in eq 9 because YBP values vary with structure as shown in eq 6.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.