메뉴 건너뛰기




Volumn 49, Issue 3, 2010, Pages 216-227

Development of a new method for deriving initial fittings for hearing aids with multi-channel compression: CAMEQ2-HF

Author keywords

Automatic gain control; Fitting; Hearing aids; Multi channel compression

Indexed keywords

ARTICLE; AUDITORY THRESHOLD; HEARING; HEARING AID; HUMAN; PROSTHESIS; SPEECH AUDIOMETRY;

EID: 77149157541     PISSN: 14992027     EISSN: 17088186     Source Type: Journal    
DOI: 10.3109/14992020903296746     Document Type: Article
Times cited : (98)

References (57)
  • 1
    • 41449117026 scopus 로고    scopus 로고
    • The value of routine real ear measurement of the gain of digital hearing aids
    • Aazh H. & Moore B.C.J. 2007. The value of routine real ear measurement of the gain of digital hearing aids. J Am Acad Audiol, 18, 655-666.
    • (2007) J Am Acad Audiol , vol.18 , pp. 655-666
    • Aazh, H.1    Moore, B.C.J.2
  • 2
    • 0742323566 scopus 로고    scopus 로고
    • Comparison of three procedures for initial fitting of compression hearing aids. II. Experienced users, fitted unilaterally
    • Alcántara J.I., Moore B.C.J. & Marriage J.E. 2004. Comparison of three procedures for initial fitting of compression hearing aids. II. Experienced users, fitted unilaterally. Int J Audiol, 43, 3-14.
    • (2004) Int J Audiol , vol.43 , pp. 3-14
    • Alcántara, J.I.1    Moore, B.C.J.2    Marriage, J.E.3
  • 5
    • 0024502662 scopus 로고
    • Transfer functions and correction factors used in hearing aid evaluation and research
    • Bentler R.A. & Pavlovic C.V. 1989. Transfer functions and correction factors used in hearing aid evaluation and research. Ear Hear, 10, 58-63.
    • (1989) Ear Hear , vol.10 , pp. 58-63
    • Bentler, R.A.1    Pavlovic, C.V.2
  • 6
    • 0026665222 scopus 로고
    • Addendum to 'transfer functions and correction factors used in hearing aid evaluation and research'
    • Bentler R.A. & Pavlovic C.V. 1992. Addendum to 'transfer functions and correction factors used in hearing aid evaluation and research'. Ear Hear, 13, 284-286.
    • (1992) Ear Hear , vol.13 , pp. 284-286
    • Bentler, R.A.1    Pavlovic, C.V.2
  • 7
    • 0016522748 scopus 로고
    • Anthropometric manikin for acoustic research
    • Burkhard M.D. & Sachs R.M. 1975. Anthropometric manikin for acoustic research. J Acoust Soc Am, 58, 214-222.
    • (1975) J Acoust Soc Am , vol.58 , pp. 214-222
    • Burkhard, M.D.1    Sachs, R.M.2
  • 8
    • 0022517008 scopus 로고
    • The National Acoustic Laboratories' (NAL) new procedure for selecting the gain and frequency response of a hearing aid
    • Byrne D. & Dillon H. 1986. The National Acoustic Laboratories' (NAL) new procedure for selecting the gain and frequency response of a hearing aid. Ear Hear, 7, 257-265.
    • (1986) Ear Hear , vol.7 , pp. 257-265
    • Byrne, D.1    Dillon, H.2
  • 9
    • 0034752764 scopus 로고    scopus 로고
    • NAL-NL1 procedure for fitting nonlinear hearing aids: Characteristics and comparisons with other procedures
    • Byrne D., Dillon H., Ching T., Katsch R. & Keidser G. 2001. NAL-NL1 procedure for fitting nonlinear hearing aids: Characteristics and comparisons with other procedures. J Am Acad Audiol, 12, 37-51.
    • (2001) J Am Acad Audiol , vol.12 , pp. 37-51
    • Byrne, D.1    Dillon, H.2    Ching, T.3    Katsch, R.4    Keidser, G.5
  • 10
    • 0027941802 scopus 로고
    • An international comparison of long-term average speech spectra
    • Byrne D., Dillon H., Tran K., Arlinger S., Wilbraham K. et al. 1994. An international comparison of long-term average speech spectra. J Acoust Soc Am, 96, 2108-2120.
    • (1994) J Acoust Soc Am , vol.96 , pp. 2108-2120
    • Byrne, D.1    Dillon, H.2    Tran, K.3    Arlinger, S.4    Wilbraham, K.5
  • 11
    • 0030874880 scopus 로고    scopus 로고
    • Field-to-microphone transfer functions for completely-in-the-canal (CIC) instruments
    • Cornelisse L.E. & Seewald R.C. 1997. Field-to-microphone transfer functions for completely-in-the-canal (CIC) instruments. Ear Hear, 18, 342-345.
    • (1997) Ear Hear , vol.18 , pp. 342-345
    • Cornelisse, L.E.1    Seewald, R.C.2
  • 12
    • 0034920512 scopus 로고    scopus 로고
    • ICRA noises: Artificial noise signals with speech-like spectral and temporal properties for hearing instrument assessment
    • Dreschler W.A., Verschuure H., Ludvigsen C. & Westermann S. 2001. ICRA noises: Artificial noise signals with speech-like spectral and temporal properties for hearing instrument assessment. Audiology, 40, 148-157.
    • (2001) Audiology , vol.40 , pp. 148-157
    • Dreschler, W.A.1    Verschuure, H.2    Ludvigsen, C.3    Westermann, S.4
  • 13
    • 0002439510 scopus 로고
    • Auditory patterns
    • Fletcher H. 1940. Auditory patterns. Rev Mod Phys, 12, 47-65.
    • (1940) Rev Mod Phys , vol.12 , pp. 47-65
    • Fletcher, H.1
  • 14
    • 77149176870 scopus 로고    scopus 로고
    • Preliminary evaluation of a method for fitting hearing aids with extended bandwidth
    • submitted
    • Füllgrabe C., Baer T., Stone M.A. & Moore B.C.J. 2009. Preliminary evaluation of a method for fitting hearing aids with extended bandwidth. (submitted).
    • (2009)
    • Füllgrabe, C.1    Baer, T.2    Stone, M.A.3    Moore, B.C.J.4
  • 15
    • 0022606309 scopus 로고
    • Auditory filter shapes in subjects with unilateral and bilateral cochlear impairments
    • Glasberg B.R. & Moore B.C.J. 1986. Auditory filter shapes in subjects with unilateral and bilateral cochlear impairments. J Acoust Soc Am, 79, 1020-1033.
    • (1986) J Acoust Soc Am , vol.79 , pp. 1020-1033
    • Glasberg, B.R.1    Moore, B.C.J.2
  • 16
    • 0025110885 scopus 로고
    • Derivation of auditory filter shapes from notched-noise data
    • Glasberg B.R. & Moore B.C.J. 1990. Derivation of auditory filter shapes from notched-noise data. Hear Res, 47, 103-138.
    • (1990) Hear Res , vol.47 , pp. 103-138
    • Glasberg, B.R.1    Moore, B.C.J.2
  • 17
    • 77149132074 scopus 로고    scopus 로고
    • Perzeptive Evaluierung von Methoden zur Sprachverbesserung in modernen digitalen Hörgeräten.
    • ITG-FB 192, Kiel
    • Hamacher V. 2006. Perzeptive Evaluierung von Methoden zur Sprachverbesserung in modernen digitalen Hörgeräten. Sprachkommunikation 2006 (ITG-FB 192), Kiel.
    • (2006) Sprachkommunikation , pp. 2006
    • Hamacher, V.1
  • 18
    • 0023433815 scopus 로고
    • Insertion gain repeatability versus loudspeaker location: You want me to put my loudspeaker where?
    • Killion M.C. & Revit L.J. 1987. Insertion gain repeatability versus loudspeaker location: You want me to put my loudspeaker where? Ear Hear, 8, 68S-73S.
    • (1987) Ear Hear , vol.8
    • Killion, M.C.1    Revit, L.J.2
  • 19
    • 0020074417 scopus 로고
    • Evaluation of high-fidelity hearing aids
    • Killion M.C. & Tillman T.W. 1982. Evaluation of high-fidelity hearing aids. J Speech Hear Res, 25, 15-25.
    • (1982) J Speech Hear Res , vol.25 , pp. 15-25
    • Killion, M.C.1    Tillman, T.W.2
  • 20
    • 1942502306 scopus 로고    scopus 로고
    • Comparison of three procedures for initial fitting of compression hearing aids. III. Inexperienced versus experienced users
    • Marriage J.E., Moore B.C.J. & Alcántara J.I. 2004. Comparison of three procedures for initial fitting of compression hearing aids. III. Inexperienced versus experienced users. Int J Audiol, 43, 198-210.
    • (2004) Int J Audiol , vol.43 , pp. 198-210
    • Marriage, J.E.1    Moore, B.C.J.2    Alcántara, J.I.3
  • 21
    • 0022835122 scopus 로고
    • Parallels between frequency selectivity measured psychophysically and in cochlear mechanics
    • Moore B.C.J. 1986. Parallels between frequency selectivity measured psychophysically and in cochlear mechanics. Scand Audiol, Suppl. 25, 139-152.
    • (1986) Scand Audiol, Suppl , vol.25 , pp. 139-152
    • Moore, B.C.J.1
  • 22
    • 0033923692 scopus 로고    scopus 로고
    • Use of a loudness model for hearing aid fitting. IV. Fitting hearing aids with multi-channel compression so as to restore 'normal' loudness for speech at different levels
    • Moore B.C.J. 2000. Use of a loudness model for hearing aid fitting. IV. Fitting hearing aids with multi-channel compression so as to restore 'normal' loudness for speech at different levels. Br J Audiol, 34, 165-177.
    • (2000) Br J Audiol , vol.34 , pp. 165-177
    • Moore, B.C.J.1
  • 24
    • 1842559775 scopus 로고    scopus 로고
    • Dead regions in the cochlea: Conceptual foundations, diagnosis, and clinical applications
    • Moore B.C.J. 2004. Dead regions in the cochlea: Conceptual foundations, diagnosis, and clinical applications. Ear Hear, 25, 98-116.
    • (2004) Ear Hear , vol.25 , pp. 98-116
    • Moore, B.C.J.1
  • 25
    • 68949154290 scopus 로고    scopus 로고
    • The use of a loudness model to derive initial fittings for hearing aids: Validation studies
    • T. Anderson, C.B. Larsen, T. Poulsen, A.N. Rasmussen & J.B. Simonsen eds
    • Moore B.C.J. 2005. The use of a loudness model to derive initial fittings for hearing aids: Validation studies. In: T. Anderson, C.B. Larsen, T. Poulsen, A.N. Rasmussen & J.B. Simonsen (eds.) Hearing Aid Fitting, Denmark: Holmens Trykkeri, pp. 11-33.
    • (2005) Hearing Aid Fitting, Denmark: Holmens Trykkeri , pp. 11-33
    • Moore, B.C.J.1
  • 26
    • 0035694605 scopus 로고    scopus 로고
    • Comparison of three procedures for initial fitting of compression hearing aids. I. Experienced users, fitted bilaterally
    • Moore B.C.J., Alcántara J.I. & Marriage J.E. 2001. Comparison of three procedures for initial fitting of compression hearing aids. I. Experienced users, fitted bilaterally. Br J Audiol, 35, 339-353.
    • (2001) Br J Audiol , vol.35 , pp. 339-353
    • Moore, B.C.J.1    Alcántara, J.I.2    Marriage, J.E.3
  • 27
    • 0032806898 scopus 로고    scopus 로고
    • Use of a loudness model for hearing aid fitting. II. Hearing aids with multi-channel compression
    • Moore B.C.J., Alcántara J.I., Stone M.A. & Glasberg B.R. 1999a. Use of a loudness model for hearing aid fitting. II. Hearing aids with multi-channel compression. Br J Audiol, 33, 157-170.
    • (1999) Br J Audiol , vol.33 , pp. 157-170
    • Moore, B.C.J.1    Alcántara, J.I.2    Stone, M.A.3    Glasberg, B.R.4
  • 28
    • 0020816083 scopus 로고
    • Suggested formulae for calculating auditory-filter bandwidths and excitation patterns
    • Moore B.C.J. & Glasberg B.R. 1983. Suggested formulae for calculating auditory-filter bandwidths and excitation patterns. J Acoust Soc Am, 74, 750-753.
    • (1983) J Acoust Soc Am , vol.74 , pp. 750-753
    • Moore, B.C.J.1    Glasberg, B.R.2
  • 29
    • 0030895316 scopus 로고    scopus 로고
    • A model of loudness perception applied to cochlear hearing loss
    • Moore B.C.J. & Glasberg B.R. 1997. A model of loudness perception applied to cochlear hearing loss. Auditory Neurosci, 3, 289-311.
    • (1997) Auditory Neurosci , vol.3 , pp. 289-311
    • Moore, B.C.J.1    Glasberg, B.R.2
  • 30
    • 0031794610 scopus 로고    scopus 로고
    • Use of a loudness model for hearing aid fitting. I. Linear hearing aids
    • Moore B.C.J. & Glasberg B.R. 1998. Use of a loudness model for hearing aid fitting. I. Linear hearing aids. Br J Audiol, 32, 317-335.
    • (1998) Br J Audiol , vol.32 , pp. 317-335
    • Moore, B.C.J.1    Glasberg, B.R.2
  • 31
    • 0842283500 scopus 로고    scopus 로고
    • A revised model of loudness perception applied to cochlear hearing loss
    • Moore B.C.J. & Glasberg B.R. 2004. A revised model of loudness perception applied to cochlear hearing loss. Hear Res, 188, 70-88.
    • (2004) Hear Res , vol.188 , pp. 70-88
    • Moore, B.C.J.1    Glasberg, B.R.2
  • 32
    • 0031119324 scopus 로고    scopus 로고
    • A model for the prediction of thresholds, loudness, and partial loudness
    • Moore B.C.J., Glasberg B.R. & Baer T. 1997. A model for the prediction of thresholds, loudness, and partial loudness. J Audio Eng Soc, 45, 224-240.
    • (1997) J Audio Eng Soc , vol.45 , pp. 224-240
    • Moore, B.C.J.1    Glasberg, B.R.2    Baer, T.3
  • 33
    • 0032886381 scopus 로고    scopus 로고
    • Use of a loudness model for hearing aid fitting. III. A general method for deriving initial fittings for hearing aids with multi-channel compression
    • Moore B.C.J., Glasberg B.R. & Stone M.A. 1999b. Use of a loudness model for hearing aid fitting. III. A general method for deriving initial fittings for hearing aids with multi-channel compression. Br J Audiol, 33, 241-258.
    • (1999) Br J Audiol , vol.33 , pp. 241-258
    • Moore, B.C.J.1    Glasberg, B.R.2    Stone, M.A.3
  • 34
    • 4544332784 scopus 로고    scopus 로고
    • The effect on speech intelligibility of varying compression time constants in a digital hearing aid
    • Moore B.C.J., Stainsby T.H., Alcántara J.I. & Kühnel V. 2004. The effect on speech intelligibility of varying compression time constants in a digital hearing aid. Int J Audiol, 43, 399-409.
    • (2004) Int J Audiol , vol.43 , pp. 399-409
    • Moore, B.C.J.1    Stainsby, T.H.2    Alcántara, J.I.3    Kühnel, V.4
  • 35
    • 60849113461 scopus 로고    scopus 로고
    • Spectro-temporal characteristics of speech at high frequencies, and the potential for restoration of audibility to people with mild-to-moderate hearing loss
    • Moore B.C.J., Stone M.A., Füllgrabe C., Glasberg B.R. & Puria S. 2008. Spectro-temporal characteristics of speech at high frequencies, and the potential for restoration of audibility to people with mild-to-moderate hearing loss. Ear Hear, 29, 907-922.
    • (2008) Ear Hear , vol.29 , pp. 907-922
    • Moore, B.C.J.1    Stone, M.A.2    Füllgrabe, C.3    Glasberg, B.R.4    Puria, S.5
  • 36
    • 0038504597 scopus 로고    scopus 로고
    • Perceived naturalness of spectrally distorted speech and music
    • Moore B.C.J. & Tan C.T. 2003. Perceived naturalness of spectrally distorted speech and music. J Acoust Soc Am, 114, 408-419.
    • (2003) J Acoust Soc Am , vol.114 , pp. 408-419
    • Moore, B.C.J.1    Tan, C.T.2
  • 38
    • 0346938088 scopus 로고    scopus 로고
    • Average speech levels and spectra in various speaking/listening conditions: A summary of the Pearson, Bennett, & Fidell (1977) report
    • Olsen W.O. 1998. Average speech levels and spectra in various speaking/listening conditions: A summary of the Pearson, Bennett, & Fidell (1977) report. Am J Audiol, 7, 21-25.
    • (1998) Am J Audiol , vol.7 , pp. 21-25
    • Olsen, W.O.1
  • 39
    • 0003722547 scopus 로고
    • Speech Levels in Various Environments
    • Report No. 3281. Cambridge, Massachusetts: Bolt, Beranek and Newman
    • Pearsons K.S., Bennett R.L. & Fidell S. 1976. Speech Levels in Various Environments. Report No. 3281. Cambridge, Massachusetts: Bolt, Beranek and Newman.
    • (1976)
    • Pearsons, K.S.1    Bennett, R.L.2    Fidell, S.3
  • 40
    • 34247846191 scopus 로고    scopus 로고
    • The objective and subjective evaluation of multichannel expansion in wide dynamic range compression hearing instruments
    • Plyler P.N., Lowery K.J., Hamby H.M. & Trine T.D. 2007. The objective and subjective evaluation of multichannel expansion in wide dynamic range compression hearing instruments. J Sp Lang Hear Res, 50, 15-24.
    • (2007) J Sp Lang Hear Res , vol.50 , pp. 15-24
    • Plyler, P.N.1    Lowery, K.J.2    Hamby, H.M.3    Trine, T.D.4
  • 41
    • 84944526586 scopus 로고
    • Low-noise noise
    • Pumplin J. 1985. Low-noise noise. J Acoust Soc Am, 78, 100-104.
    • (1985) J Acoust Soc Am , vol.78 , pp. 100-104
    • Pumplin, J.1
  • 42
    • 15944404511 scopus 로고    scopus 로고
    • Real-ear measures
    • M. Valente, H. Hosford-Dunn & R.J. Roeser eds, New York: Thieme, pp
    • Revit L.J. 2000. Real-ear measures. In: M. Valente, H. Hosford-Dunn & R.J. Roeser (eds.) Audiology: Treatment, New York: Thieme, pp. 105-146.
    • (2000) Audiology: Treatment , pp. 105-146
    • Revit, L.J.1
  • 43
    • 38849157992 scopus 로고    scopus 로고
    • High frequency amplification and sound quality in listeners with normal through moderate hearing loss
    • Ricketts T.A., Dittberner A.B. & Johnson E.E. 2008. High frequency amplification and sound quality in listeners with normal through moderate hearing loss. J Speech Lang Hear Res, 51, 160-172.
    • (2008) J Speech Lang Hear Res , vol.51 , pp. 160-172
    • Ricketts, T.A.1    Dittberner, A.B.2    Johnson, E.E.3
  • 45
    • 0016345542 scopus 로고
    • Transformation of sound pressure level from the free field to the eardrum in the horizontal plane
    • Shaw E.A.G. 1974. Transformation of sound pressure level from the free field to the eardrum in the horizontal plane. J Acoust Soc Am, 56, 1848-1861.
    • (1974) J Acoust Soc Am , vol.56 , pp. 1848-1861
    • Shaw, E.A.G.1
  • 46
    • 0020622933 scopus 로고
    • Amplification bandwidth and intelligibility of speech in quiet and noise for listeners with sensorineural hearing loss
    • Skinner M.W. & Miller J.D. 1983. Amplification bandwidth and intelligibility of speech in quiet and noise for listeners with sensorineural hearing loss. Audiology, 22, 253-279.
    • (1983) Audiology , vol.22 , pp. 253-279
    • Skinner, M.W.1    Miller, J.D.2
  • 47
    • 1842507419 scopus 로고    scopus 로고
    • Is normal or less than normal overall loudness preferred by first-time hearing aid users?
    • Smeds K. 2004. Is normal or less than normal overall loudness preferred by first-time hearing aid users? Ear Hear, 25, 159-172.
    • (2004) Ear Hear , vol.25 , pp. 159-172
    • Smeds, K.1
  • 48
    • 28844503440 scopus 로고    scopus 로고
    • Preferred overall loudness. II: Listening through hearing aids in field and laboratory tests
    • Smeds K., Keidser G., Zakis J., Dillon H., Leijon A. et al. 2006. Preferred overall loudness. II: Listening through hearing aids in field and laboratory tests. Int J Audiol, 45, 12-25.
    • (2006) Int J Audiol , vol.45 , pp. 12-25
    • Smeds, K.1    Keidser, G.2    Zakis, J.3    Dillon, H.4    Leijon, A.5
  • 49
    • 0042569076 scopus 로고    scopus 로고
    • Effect of the speed of a single-channel dynamic range compressor on intelligibility in a competing speech task
    • Stone M.A. & Moore B.C.J. 2003. Effect of the speed of a single-channel dynamic range compressor on intelligibility in a competing speech task. J Acoust Soc Am, 114, 1023-1034.
    • (2003) J Acoust Soc Am , vol.114 , pp. 1023-1034
    • Stone, M.A.1    Moore, B.C.J.2
  • 50
    • 3142550470 scopus 로고    scopus 로고
    • Estimated variability of Real Ear Insertion Response (REIR) with loudspeaker type and placement
    • Stone M.A. & Moore B.C.J. 2004a. Estimated variability of Real Ear Insertion Response (REIR) with loudspeaker type and placement. Int J Audiol, 43, 271-275.
    • (2004) Int J Audiol , vol.43 , pp. 271-275
    • Stone, M.A.1    Moore, B.C.J.2
  • 51
    • 6344238549 scopus 로고    scopus 로고
    • Side effects of fast-acting dynamic range compression that affect intelligibility in a competing speech task
    • Stone M.A. & Moore B.C.J. 2004b. Side effects of fast-acting dynamic range compression that affect intelligibility in a competing speech task. J Acoust Soc Am, 116, 2311-2323.
    • (2004) J Acoust Soc Am , vol.116 , pp. 2311-2323
    • Stone, M.A.1    Moore, B.C.J.2
  • 52
    • 38849154558 scopus 로고    scopus 로고
    • Effects of spectro-temporal modulation changes produced by multi-channel compression on intelligibility in a competing-speech task
    • Stone M.A. & Moore B.C.J. 2008. Effects of spectro-temporal modulation changes produced by multi-channel compression on intelligibility in a competing-speech task. J Acoust Soc Am, 123, 1063-1076.
    • (2008) J Acoust Soc Am , vol.123 , pp. 1063-1076
    • Stone, M.A.1    Moore, B.C.J.2
  • 53
    • 0032784425 scopus 로고    scopus 로고
    • Comparison of different forms of compression using wearable digital hearing aids
    • Stone M.A., Moore B.C.J., Alcántara J.I. & Glasberg B.R. 1999. Comparison of different forms of compression using wearable digital hearing aids. J Acoust Soc Am, 106, 3603-3619.
    • (1999) J Acoust Soc Am , vol.106 , pp. 3603-3619
    • Stone, M.A.1    Moore, B.C.J.2    Alcántara, J.I.3    Glasberg, B.R.4
  • 54
    • 54049156502 scopus 로고    scopus 로고
    • Tolerable hearing-aid delays. V. Estimation of limits for open canal fittings
    • Stone M.A., Moore B.C.J., Meisenbacher K. & Derleth R.P. 2008. Tolerable hearing-aid delays. V. Estimation of limits for open canal fittings. Ear Hear, 29, 601-617.
    • (2008) Ear Hear , vol.29 , pp. 601-617
    • Stone, M.A.1    Moore, B.C.J.2    Meisenbacher, K.3    Derleth, R.P.4
  • 55
    • 0028345673 scopus 로고
    • The effect of syllabic compression and frequency shaping on speech intelligibility in hearing impaired people
    • Verschuure J., Prinsen T.T. & Dreschler W.A. 1994. The effect of syllabic compression and frequency shaping on speech intelligibility in hearing impaired people. Ear Hear, 15, 13-21.
    • (1994) Ear Hear , vol.15 , pp. 13-21
    • Verschuure, J.1    Prinsen, T.T.2    Dreschler, W.A.3
  • 56
    • 0034902191 scopus 로고    scopus 로고
    • Effects of lowpass filtering on the intelligibility of speech in quiet for people with and without dead regions at high frequencies
    • Vickers D.A., Moore B.C.J. & Baer T. 2001. Effects of lowpass filtering on the intelligibility of speech in quiet for people with and without dead regions at high frequencies. J Acoust Soc Am, 110, 1164-1175.
    • (2001) J Acoust Soc Am , vol.110 , pp. 1164-1175
    • Vickers, D.A.1    Moore, B.C.J.2    Baer, T.3
  • 57
    • 0002237909 scopus 로고
    • Masking and psychological excitation as consequences of the ear's frequency analysis
    • R. Plomp & G.F. Smoorenburg eds, Leiden: Sijthoff, pp
    • Zwicker E. 1970. Masking and psychological excitation as consequences of the ear's frequency analysis. In: R. Plomp & G.F. Smoorenburg (eds.) Frequency Analysis and Periodicity Detection in Hearing, Leiden: Sijthoff, pp. 376-394.
    • (1970) Frequency Analysis and Periodicity Detection in Hearing , pp. 376-394
    • Zwicker, E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.