-
1
-
-
26444510219
-
Extending reperfusion therapy for acute ischemic stroke: Emerging pharmacological, mechanical, and imaging strategies
-
Molina CA, Saver JL. Extending reperfusion therapy for acute ischemic stroke: emerging pharmacological, mechanical, and imaging strategies. Stroke 2005; 36 (10): 2311-2320
-
(2005)
Stroke
, vol.36
, Issue.10
, pp. 2311-2320
-
-
Molina, C.A.1
Saver, J.L.2
-
2
-
-
0042282011
-
Trial design and reporting standards for intra-arterial cerebral thrombolysis for acute ischemic stroke
-
Higashida RT, Furlan AJ, Roberts H, et al. Trial design and reporting standards for intra-arterial cerebral thrombolysis for acute ischemic stroke. Stroke 2003; 34 (8): e109-37
-
(2003)
Stroke
, vol.34
, Issue.8
-
-
Higashida, R.T.1
Furlan, A.J.2
Roberts, H.3
-
3
-
-
34247844511
-
Guidelines for the earlymanagement of adults with ischemic stroke: A guideline from the American Heart Association/American Stroke Association Stroke Council, Clinical Cardiology Council, Cardiovascular Radiology and Intervention Council
-
Atherosclerotic Peripheral Vascular Disease and Quality of Care Outcomes in Research Interdisciplinary Working Groups: The American Academy of Neurology affirms the value of this guideline as an educational tool for neurologists
-
Adams JrHP, del Zoppo G,AlbertsMJ, et al.Guidelines for the earlymanagement of adults with ischemic stroke: a guideline from the American Heart Association/ American Stroke Association Stroke Council, Clinical Cardiology Council, Cardiovascular Radiology and Intervention Council, and the Atherosclerotic Peripheral Vascular Disease and Quality of Care Outcomes in Research Interdisciplinary Working Groups: the American Academy of Neurology affirms the value of this guideline as an educational tool for neurologists. Stroke 2007; 38 (5): 1655-1711
-
(2007)
Stroke
, vol.38
, Issue.5
, pp. 1655-1711
-
-
Adams Jr., H.P.1
Zoppo, G.2
Alberts, M.J.3
-
4
-
-
52649165720
-
Thrombolysiswith alteplase 3 to 4.5 hours after acute ischemic stroke
-
HackeW, KasteM,Bluhmki E, et al.Thrombolysiswith alteplase 3 to 4.5 hours after acute ischemic stroke. N Engl J Med 2008; 359 (13): 1317-1329
-
(2008)
N Engl J Med
, vol.359
, Issue.13
, pp. 1317-1329
-
-
Hacke, W.1
Kaste, M.2
Bluhmki, E.3
-
5
-
-
35649003821
-
Facilities available in European hospitals treating stroke patients
-
Leys D, Ringelstein EB, Kaste M, et al. Facilities available in European hospitals treating stroke patients. Stroke 2007; 38 (11): 2985-2991
-
(2007)
Stroke
, vol.38
, Issue.11
, pp. 2985-2991
-
-
Leys, D.1
Ringelstein, E.B.2
Kaste, M.3
-
6
-
-
7644242450
-
Ultrasound identification and lysis of clots
-
Alexandrov AV. Ultrasound identification and lysis of clots. Stroke 2004; 35 (11 Suppl. 1): 2722-2725
-
(2004)
Stroke
, vol.35
, Issue.11 SUPPL. 1
, pp. 2722-2725
-
-
Alexandrov, A.V.1
-
7
-
-
8644230974
-
Ultrasound-enhanced systemic thrombolysis for acute ischemic stroke
-
Alexandrov AV, Molina CA, Grotta JC, et al. Ultrasound-enhanced systemic thrombolysis for acute ischemic stroke. N Engl JMed 2004; 351 (21): 2170-2178
-
(2004)
N Engl JMed
, vol.351
, Issue.21
, pp. 2170-2178
-
-
Alexandrov, A.V.1
Molina, C.A.2
Grotta, J.C.3
-
9
-
-
0026856566
-
Enhancement of fibrinolysiswith ultrasound energy
-
TachibanaK.Enhancement of fibrinolysiswith ultrasound energy. JVasc IntervRadiol 1992; 3 (2): 299-303
-
(1992)
J Vasc Interv Radiol
, vol.3
, Issue.2
, pp. 299-303
-
-
Tachibana, K.1
-
10
-
-
0026726595
-
Effect of ultrasound on tissue-type plasminogen activator-induced thrombolysis
-
Lauer CG, Burge R, Tang DB, et al. Effect of ultrasound on tissue-type plasminogen activator-induced thrombolysis. Circulation 1992; 86 (4): 1257-1264
-
(1992)
Circulation
, vol.86
, Issue.4
, pp. 1257-1264
-
-
Lauer, C.G.1
Burge, R.2
Tang, D.B.3
-
11
-
-
0029759756
-
Transcutaneous ultrasound augments lysis of arterial thrombi in vivo
-
Luo H, Nishioka T, Fishbein MC, et al. Transcutaneous ultrasound augments lysis of arterial thrombi in vivo. Circulation 1996; 94 (4): 775-778
-
(1996)
Circulation
, vol.94
, Issue.4
, pp. 775-778
-
-
Luo, H.1
Nishioka, T.2
Fishbein, M.C.3
-
12
-
-
77149140625
-
Ultrasound therapy for stroke and regenerative medicine
-
Tachibana K. Ultrasound therapy for stroke and regenerative medicine. Int Congr Ser 2004; 1274: 153-158
-
(2004)
Int Congr ser
, vol.1274
, pp. 153-158
-
-
Tachibana, K.1
-
13
-
-
8644277187
-
Ultrasound energy and the dissolution of thrombus
-
Polak JF.Ultrasound energy and the dissolution of thrombus.NEngl JMed 2004; 351 (21): 2154-2155
-
(2004)
N Engl J Med
, vol.351
, Issue.21
, pp. 2154-2155
-
-
Polak, J.F.1
-
14
-
-
0030826774
-
Ultrasound reversibly disaggregates fibrin fibers
-
Braaten JV, Goss RA, Francis CW. Ultrasound reversibly disaggregates fibrin fibers. Thromb Haemost 1997; 78 (3): 1063-1068
-
(1997)
Thromb Haemost
, vol.78
, Issue.3
, pp. 1063-1068
-
-
Braaten, J.V.1
Goss, R.A.2
Francis, C.W.3
-
15
-
-
0032521423
-
Binding of tissue-plasminogen activator to fibrin: Effect of ultrasound
-
Siddiqi F, Odrljin TM, Fay PJ, et al. Binding of tissue-plasminogen activator to fibrin: effect of ultrasound. Blood 1998; 91 (6): 2019-2025
-
(1998)
Blood
, vol.91
, Issue.6
, pp. 2019-2025
-
-
Siddiqi, F.1
Odrljin, T.M.2
Fay, P.J.3
-
16
-
-
20844441598
-
Et al.Ultrasound affects distribution of plasminogen and tissue-type plasminogen activator in whole blood clots in vitro
-
Devcic-Kuhar B, Pfaffenberger S, Gherardini L, et al.Ultrasound affects distribution of plasminogen and tissue-type plasminogen activator in whole blood clots in vitro. Thromb Haemost 2004; 92 (5): 980-985
-
(2004)
Thromb Haemost
, vol.92
, Issue.5
, pp. 980-985
-
-
Devcic-Kuhar, B.1
Pfaffenberger, S.2
Gherardini, L.3
-
17
-
-
0029154850
-
Albumin microbubble echo-contrast material as an enhancer for ultrasound accelerated thrombolysis
-
Tachibana K, Tachibana S. Albumin microbubble echo-contrast material as an enhancer for ultrasound accelerated thrombolysis. Circulation 1995; 92 (5): 1148-1150
-
(1995)
Circulation
, vol.92
, Issue.5
, pp. 1148-1150
-
-
Tachibana, K.1
Tachibana, S.2
-
18
-
-
0027270150
-
Enhancementof thrombolysis by externalultrasound
-
LuoH, SteffenW,CercekB, et al.Enhancementof thrombolysis by externalultrasound. Am Heart J 1993; 125 (6): 1564-1569
-
(1993)
Am Heart J
, vol.125
, Issue.6
, pp. 1564-1569
-
-
Luo, H.1
Steffen, W.2
Cercek, B.3
-
19
-
-
33645124729
-
Pulsed high-intensity focused ultrasound enhances thrombolysis in an in vitro model
-
FrenkelV,Oberoi J, Stone MJ, et al. Pulsed high-intensity focused ultrasound enhances thrombolysis in an in vitro model. Radiology 2006; 239 (1): 86-93
-
(2006)
Radiology
, vol.239
, Issue.1
, pp. 86-93
-
-
Frenkelvoberoi, J.1
Stone, M.J.2
-
20
-
-
20144364780
-
Influence of ultrasound operating parameters on ultrasound-induced thrombolysis in vitro
-
Schafer S, Kliner S, KlinghammerL, et al. Influence of ultrasound operating parameters on ultrasound-induced thrombolysis in vitro. Ultrasound MedBiol 2005; 31 (6): 841-847
-
(2005)
Ultrasound MedBiol
, vol.31
, Issue.6
, pp. 841-847
-
-
Schafer, S.1
Klinghammerl, K.S.2
-
21
-
-
19944427615
-
Can a commercial diagnostic ultrasounddevice accelerate thrombolysis?An in vitro skullmodel
-
Pfaffenberger S, Devcic-Kuhar B, Kollmann C, et al. Can a commercial diagnostic ultrasounddevice accelerate thrombolysis?An in vitro skullmodel. Stroke 2005; 36 (1): 124-128
-
(2005)
Stroke
, vol.36
, Issue.1
, pp. 124-128
-
-
Pfaffenberger, S.1
Devcic-Kuhar, B.2
Kollmann, C.3
-
22
-
-
0032497273
-
Enhancement of fibrinolysis with 40-kHz ultrasound
-
SuchkovaV, SiddiqiFN, CarstensenEL, et al. Enhancement of fibrinolysis with 40-kHz ultrasound. Circulation 1998; 98 (10): 1030-1035
-
(1998)
Circulation
, vol.98
, Issue.10
, pp. 1030-1035
-
-
Suchkova, V.1
Siddiqi, F.N.2
Carstensen, E.L.3
-
23
-
-
22044441701
-
Transcranial low-frequency ultrasoundmediated thrombolysis in brain ischemia: Increased risk of hemorrhage with combined ultrasound and tissue plasminogen activator: Results of a phase II clinical trial
-
Daffertshofer M, Gass A, Ringleb P, et al. Transcranial low-frequency ultrasoundmediated thrombolysis in brain ischemia: increased risk of hemorrhage with combined ultrasound and tissue plasminogen activator: results of a phase II clinical trial. Stroke 2005; 36 (7): 1441-1446
-
(2005)
Stroke
, vol.36
, Issue.7
, pp. 1441-1446
-
-
Daffertshofer, M.1
Gass, A.2
Ringleb, P.3
-
24
-
-
0037766220
-
Effect of ultrasound on thrombolysis of middle cerebral artery occlusion
-
Eggers J, Koch B, Meyer K, et al. Effect of ultrasound on thrombolysis of middle cerebral artery occlusion. Ann Neurol 2003; 53 (6): 797-800
-
(2003)
Ann Neurol
, vol.53
, Issue.6
, pp. 797-800
-
-
Eggers, J.1
Koch, B.2
Meyer, K.3
-
25
-
-
33644851343
-
Microbubble administration accelerates clot lysis during continuous 2-MHz ultrasound monitoring in stroke patients treated with intravenous tissue plasminogen activator
-
MolinaCA, RiboM,RubieraM, et al. Microbubble administration accelerates clot lysis during continuous 2-MHz ultrasound monitoring in stroke patients treated with intravenous tissue plasminogen activator. Stroke 2006; 37 (2): 425-429
-
(2006)
Stroke
, vol.37
, Issue.2
, pp. 425-429
-
-
Ribomrubieram, M.1
-
26
-
-
44449175178
-
A pilot randomized clinical safety study of sonothrombolysis augmentation with ultrasound-activated perflutrenlipid microspheres for acute ischemic stroke
-
Alexandrov AV, Mikulik R, Ribo M, et al. A pilot randomized clinical safety study of sonothrombolysis augmentation with ultrasound-activated perflutrenlipid microspheres for acute ischemic stroke. Stroke 2008; 39 (5): 1464-1469
-
(2008)
Stroke
, vol.39
, Issue.5
, pp. 1464-1469
-
-
Alexandrov, A.V.1
Mikulik, R.2
Ribo, M.3
-
27
-
-
77149177184
-
-
[online]. Available from URL: [Accessed 2009 Sep 28]
-
IMARx.TUCSONtrial [online]. Available fromURL: http://www.imarx.com/ ImaRx/ clinical-trials5-0 [Accessed 2009 Sep 28]
-
TUCSON Trial
-
-
-
28
-
-
34250719807
-
Trancranial ultrasound combined with intravenous microbubbles and tissue plasminogen activator for acute ischemic stroke: A randomized controlled study [abstract]
-
Larrue AV, Arnaud C. Trancranial ultrasound combined with intravenous microbubbles and tissue plasminogen activator for acute ischemic stroke: a randomized controlled study [abstract]. Stroke 2007; 38: 472
-
(2007)
Stroke
, vol.38
, pp. 472
-
-
Larrue, A.V.1
Arnaud, C.2
-
29
-
-
42549110330
-
Microbubble potentiated transcranial duplex ultrasound enhances IV thrombolysis in acute stroke
-
Perren F, Loulidi J, Poglia D, et al. Microbubble potentiated transcranial duplex ultrasound enhances IV thrombolysis in acute stroke. J ThrombThrombolysis 2008; 25: 219-223
-
(2008)
J Thromb Thrombolysis
, vol.25
, pp. 219-223
-
-
Perren, F.1
Loulidi, J.2
Poglia, D.3
-
30
-
-
15244339173
-
Sonothrombolysis in acute ischemic stroke for patients ineligible for rt-PA
-
Eggers J, Seidel G, Koch B, et al. Sonothrombolysis in acute ischemic stroke for patients ineligible for rt-PA. Neurology 2005; 64 (6): 1052-1054
-
(2005)
Neurology
, vol.64
, Issue.6
, pp. 1052-1054
-
-
Eggers, J.1
Seidel, G.2
Koch, B.3
-
31
-
-
34347337611
-
The InterventionalManagement of Stroke (IMS) II study
-
IMS II Trial Investigators
-
IMS II Trial Investigators. The InterventionalManagement of Stroke (IMS) II study. Stroke 2007; 38 (7): 2127-2135
-
(2007)
Stroke
, vol.38
, Issue.7
, pp. 2127-2135
-
-
-
32
-
-
0042512293
-
Ultrasound in the treatment of ischaemic stroke
-
Daffertshofer M, Hennerici M. Ultrasound in the treatment of ischaemic stroke. Lancet Neurol 2003; 2 (5): 283-290
-
(2003)
Lancet Neurol
, vol.2
, Issue.5
, pp. 283-290
-
-
Daffertshofer, M.1
Hennerici, M.2
-
33
-
-
48149110814
-
Ultrasound enhanced thrombolysis in acute arterial ischemia
-
Tsivgoultrasound enhanced thrombolysis in acute arterial ischemia. Ultrasonics 2008; 48 (4): 303-311
-
(2008)
Ultrasonics
, vol.48
, Issue.4
, pp. 303-311
-
-
Tsivgoulis, G.1
Culp, W.C.2
Alexandrov, A.V.3
-
34
-
-
38949156591
-
Design of a PROspective multi-national CLOTBUST collaboration on reperfusion therapies for stroke (CLOTBUST-PRO)
-
Saqqur M, Tsivgoulis G, Molina CA, et al. Design of a PROspective multi-national CLOTBUST collaboration on reperfusion therapies for stroke (CLOTBUST-PRO). Int J Stroke 2008; 3 (1): 66-72
-
(2008)
Int J Stroke
, vol.3
, Issue.1
, pp. 66-72
-
-
Saqqur, M.1
Tsivgoulis, G.2
Molina, C.A.3
-
35
-
-
34250730176
-
Ultrasound-enhanced thrombolysis in acute ischemic stroke: Potential, failures, and safety
-
Tsivgoulis G, Alexandrov AV. Ultrasound-enhanced thrombolysis in acute ischemic stroke: potential, failures, and safety. Neurotherapeutics 2007; 4 (3): 420-427
-
(2007)
Neurotherapeutics
, vol.4
, Issue.3
, pp. 420-427
-
-
Tsivgoulis, G.1
Alexandrov, A.V.2
-
36
-
-
0032078295
-
Ultrasound contrast agents: Basic principles
-
DOI 10.1016/S0720-048X(98)00057-6, PII S0720048X98000576
-
Calliada F, CampaniR, Bottinelli O, et al.Ultrasound contrast agents: basic principles. Eur J Radiol 1998; 27 Suppl. 2: S157-60 (Pubitemid 28270589)
-
(1998)
European Journal of Radiology
, vol.27
, Issue.SUPPL. 2
-
-
Calliada, F.1
Campani, R.2
Bottinelli, O.3
Bozzini, A.4
Sommaruga, M.G.5
-
37
-
-
0025258575
-
Thresholds for transient cavitation produced by pulsed ultrasound in a controlled nuclei environment
-
Holland CK, Apfel RE. Thresholds for transient cavitation produced by pulsed ultrasound in a controlled nuclei environment. J Acoust Soc Am 1990; 88 (5): 2059-2069
-
(1990)
J Acoust Soc Am
, vol.88
, Issue.5
, pp. 2059-2069
-
-
Holland, C.K.1
Apfel, R.E.2
-
39
-
-
34249288983
-
Cavitational mechanisms in ultrasound-accelerated fibrinolysis
-
Prokop AF, Soltani A, Roy RA. Cavitational mechanisms in ultrasound-accelerated fibrinolysis. Ultrasound Med Biol 2007; 33 (6): 924-933
-
(2007)
Ultrasound Med Biol
, vol.33
, Issue.6
, pp. 924-933
-
-
Prokop, A.F.1
Soltani, A.2
Roy, R.A.3
-
41
-
-
0030877327
-
Dissolution of thrombotic arterial occlusion by high intensity, low frequency ultrasound and dodecafluoropentane emulsion: An in vitro and in vivo study
-
Nishioka T, Luo H, FishbeinMC, et al. Dissolution of thrombotic arterial occlusion by high intensity, low frequency ultrasound and dodecafluoropentane emulsion: an in vitro and in vivo study. J Am Coll Cardiol 1997; 30 (2): 561-568
-
(1997)
J Am Coll Cardiol
, vol.30
, Issue.2
, pp. 561-568
-
-
Nishioka, T.1
Fishbeinmc, L.H.2
-
42
-
-
0344406191
-
Microbubble-augmented ultrasound declotting of thrombosedarteriovenous dialysis grafts in dogs
-
Culp WC, Porter TR, McCowan TC, et al. Microbubble-augmented ultrasound declotting of thrombosedarteriovenous dialysis grafts in dogs. JVasc IntervRadiol 2003; 14 (3): 343-347
-
(2003)
J Vasc IntervRadiol
, vol.14
, Issue.3
, pp. 343-347
-
-
Culp, W.C.1
Porter, T.R.2
McCowan, T.C.3
-
43
-
-
4744338859
-
Intracranial clot lysis with intravenous microbubbles and transcranial ultrasound in swine
-
Culp WC, Porter TR, Lowery J, et al. Intracranial clot lysis with intravenous microbubbles and transcranial ultrasound in swine. Stroke 2004; 35 (10): 2407-2411
-
(2004)
Stroke
, vol.35
, Issue.10
, pp. 2407-2411
-
-
Culp, W.C.1
Porter, T.R.2
Lowery, J.3
-
44
-
-
0032586123
-
Enhancement of ultrasound-accelerated thrombolysis by echo contrast agents: Dependence on microbubble structure
-
Mizushige K, Kondo I, Ohmori K, et al. Enhancement of ultrasound-accelerated thrombolysis by echo contrast agents: dependence on microbubble structure. Ultrasound Med Biol 1999; 25 (9): 1431-1437
-
(1999)
Ultrasound Med Biol
, vol.25
, Issue.9
, pp. 1431-1437
-
-
Mizushige, K.1
Kondo, I.2
Ohmori, K.3
-
45
-
-
52049111224
-
Do bubble characteristics affect recanalization in stroke patients treated withmicrobubble-enhanced sonothrombolysis?
-
Rubiera M, Ribo M, Delgado-Mederos R, et al. Do bubble characteristics affect recanalization in stroke patients treated withmicrobubble-enhanced sonothrombolysis? UltrasoundMed Biol 2008; 34 (10): 1573-1577
-
(2008)
Ultrasound Med Biol
, vol.34
, Issue.10
, pp. 1573-1577
-
-
Rubiera, M.1
Ribo, M.2
Delgado-Mederos, R.3
-
46
-
-
20444498107
-
Effectiveness of lipid microbubbles and ultrasound in declotting thrombosis
-
Xie F, Tsutsui JM, Lof J, et al. Effectiveness of lipid microbubbles and ultrasound in declotting thrombosis. UltrasoundMed Biol 2005; 31 (7): 979-985
-
(2005)
Ultrasound Med Biol
, vol.31
, Issue.7
, pp. 979-985
-
-
Xie, F.1
Tsutsui, J.M.2
Lof, J.3
-
47
-
-
0032956026
-
Ultrasonic thrombolysis: Catheter-delivered and transcutaneous applications
-
Atar S, Luo H, Nagai T, et al. Ultrasonic thrombolysis: catheter-delivered and transcutaneous applications. Eur J Ultrasound 1999; 9 (1): 39-54
-
(1999)
Eur J Ultrasound
, vol.9
, Issue.1
, pp. 39-54
-
-
Atar, S.1
Luo, H.2
Nagai, T.3
|