메뉴 건너뛰기




Volumn 145, Issue 1, 2010, Pages 239-245

Binding event measurement using a chip calorimeter coupled to magnetic beads

Author keywords

Biosensor; Biotin streptavidin reaction; Chip calorimetry; DNA hybridization

Indexed keywords

APTAMERS; BASELINE STABILITY; BINDING EVENTS; BIOTIN-STREPTAVIDIN; BIOTIN-STREPTAVIDIN REACTION; CHIP CALORIMETER; DNA HYBRIDIZATION; DNA OLIGOMERS; FLOWTHROUGH; HIGH SENSITIVITY; LABEL-FREE DETECTION; MAGNETIC BEADS; NANOLITERS; SAMPLE VOLUME; SIGNAL RESOLUTION; SILICON CHIP; STREPTAVIDIN;

EID: 76949107717     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2009.12.012     Document Type: Article
Times cited : (35)

References (16)
  • 1
    • 33746932080 scopus 로고    scopus 로고
    • Current biosensor technologies in drug discovery
    • Cooper M.A. Current biosensor technologies in drug discovery. Drug Discov. World Summer (2006) 68-82
    • (2006) Drug Discov. World Summer , pp. 68-82
    • Cooper, M.A.1
  • 2
    • 1542787841 scopus 로고    scopus 로고
    • Label-free screening of bio-molecular interactions
    • Cooper M.A. Label-free screening of bio-molecular interactions. Anal. Bioanal. Chem. 377 (2003) 834-842
    • (2003) Anal. Bioanal. Chem. , vol.377 , pp. 834-842
    • Cooper, M.A.1
  • 3
    • 33751218906 scopus 로고    scopus 로고
    • Non-optical screening platforms: the next wave in label-free screening?
    • Cooper M.A. Non-optical screening platforms: the next wave in label-free screening?. Drug Discov. Today 11 (2006) 1068-1074
    • (2006) Drug Discov. Today , vol.11 , pp. 1068-1074
    • Cooper, M.A.1
  • 4
    • 41449105031 scopus 로고    scopus 로고
    • Chip calorimetry and its use for biochemical and cell biological investigations
    • Lerchner J., Maskow T., and Wolf G. Chip calorimetry and its use for biochemical and cell biological investigations. Chem. Eng. Proc. 47 (2008) 991-999
    • (2008) Chem. Eng. Proc. , vol.47 , pp. 991-999
    • Lerchner, J.1    Maskow, T.2    Wolf, G.3
  • 6
    • 42349107349 scopus 로고    scopus 로고
    • A microfrabri cated nanocalorimeter: design, characterization, and chemical calibration
    • Xu J., Reiserer R., Tellinghuisen J., Wikswo J.P., and Baudenbacher F.J. A microfrabri cated nanocalorimeter: design, characterization, and chemical calibration. Anal. Chem. 80 (2008) 2728-2733
    • (2008) Anal. Chem. , vol.80 , pp. 2728-2733
    • Xu, J.1    Reiserer, R.2    Tellinghuisen, J.3    Wikswo, J.P.4    Baudenbacher, F.J.5
  • 8
    • 76949096859 scopus 로고    scopus 로고
    • www.vivactis.be.
  • 9
    • 0027336250 scopus 로고
    • An integrated silicon thermopile as biosensor for the thermal monitoring of glucose, urea and penicillin
    • Bataillard P., Steffgen E., Haemmerli S., Manz A., and Widmer H.M. An integrated silicon thermopile as biosensor for the thermal monitoring of glucose, urea and penicillin. Biosens. Biolectron. 8 (1993) 89-98
    • (1993) Biosens. Biolectron. , vol.8 , pp. 89-98
    • Bataillard, P.1    Steffgen, E.2    Haemmerli, S.3    Manz, A.4    Widmer, H.M.5
  • 14
    • 0033621525 scopus 로고    scopus 로고
    • Direct force measurement of the streptavidin-biotin interaction
    • Wong J., Chilkoti A., and Moy V.T. Direct force measurement of the streptavidin-biotin interaction. Biomol. Eng. 16 (1999) 45-55
    • (1999) Biomol. Eng. , vol.16 , pp. 45-55
    • Wong, J.1    Chilkoti, A.2    Moy, V.T.3
  • 15
    • 0034044384 scopus 로고    scopus 로고
    • Ser45 plays an important role in managing both the equilibrium and transition state energetics of the streptavidin-biotin system
    • Hyre D.E., Le Trong I., Freitag S., and Stenkamp R.E. Ser45 plays an important role in managing both the equilibrium and transition state energetics of the streptavidin-biotin system. Prot. Sci. 9 (2000) 878-885
    • (2000) Prot. Sci. , vol.9 , pp. 878-885
    • Hyre, D.E.1    Le Trong, I.2    Freitag, S.3    Stenkamp, R.E.4
  • 16
    • 45449087291 scopus 로고    scopus 로고
    • Neisseria meningitidis detection based on a microcalorimetric biosensor with a split-flow microchannel
    • Yoon S.-I., Lim M.-H., Park S.-Ch., Shin J.-S., and Kim Y.-J. Neisseria meningitidis detection based on a microcalorimetric biosensor with a split-flow microchannel. J. Microelectromech. Syst. 17 (2008) 590-597
    • (2008) J. Microelectromech. Syst. , vol.17 , pp. 590-597
    • Yoon, S.-I.1    Lim, M.-H.2    Park, S.-Ch.3    Shin, J.-S.4    Kim, Y.-J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.