메뉴 건너뛰기




Volumn 56, Issue 1, 2010, Pages 12-16

The influence of the residual stress in silicone tubes in the calibration methods of roller pumps used in cardiopulmonary bypass

Author keywords

[No Author keywords available]

Indexed keywords

ANGULAR COEFFICIENTS; CALIBRATION METHOD; CARDIOPULMONARY BYPASS; COVARIANCE ANALYSIS; DYNAMIC CALIBRATION; ON DYNAMICS; RATE MEASUREMENTS; RED BLOOD CELL; RETROGRADE FLOW; ROLLER PUMPS; SIMPLE LINEAR REGRESSION; SURGICAL PROCEDURES;

EID: 76849086073     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/MAT.0b013e3181c8444c     Document Type: Article
Times cited : (7)

References (9)
  • 1
    • 0242440921 scopus 로고    scopus 로고
    • History of extracorporeal circulation: The invention and modification of blood pumps
    • Boettcher W, Merkle F, Weitkemper HH: History of extracorporeal circulation: The invention and modification of blood pumps. J Extra Corpor Technol 35: 184-191, 2003.
    • (2003) J Extra Corpor Technol , vol.35 , pp. 184-191
    • Boettcher, W.1    Merkle, F.2    Weitkemper, H.H.3
  • 2
    • 0343485954 scopus 로고
    • The use of a totally occlusive pump as a flow meter with observations on hemolysis caused by occlusive and nonocclusive pumps and other pump-oxygenator components
    • McCaughan JS Jr, McMichael H, Schuder JC, Kirby CK: The use of a totally occlusive pump as a flowmeter with observations on hemolysis caused by occlusive and nonocclusive pumps and other pump-oxygenator components. Surgery 44: 210-219, 1958.
    • (1958) Surgery , vol.44 , pp. 210-219
    • McCaughan Jr., J.S.1    McMichael, H.2    Schuder, J.C.3    Kirby, C.K.4
  • 3
    • 0014060282 scopus 로고
    • Factors influencing hemolysis with roller pumps
    • Bernstein EF, Gleason LR: Factors influencing hemolysis with roller pumps. Surgery 61: 432-442, 1967.
    • (1967) Surgery , vol.61 , pp. 432-442
    • Bernstein, E.F.1    Gleason, L.R.2
  • 5
    • 0001133271 scopus 로고
    • Hemolysis of blood in the pericardium: The major source of plasma hemoglobin during total body perfusion
    • Morris KN, Kinross FM, Stirling GR: Hemolysis of blood in the pericardium: The major source of plasma hemoglobin during total body perfusion. J Thorac Cardiovasc Surg 49: 250-258, 1965.
    • (1965) J Thorac Cardiovasc Surg , vol.49 , pp. 250-258
    • Morris, K.N.1    Kinross, F.M.2    Stirling, G.R.3
  • 6
    • 60349090665 scopus 로고    scopus 로고
    • Differences in displayed pump flow compared to measured flow under varying conditions during simulated cardiopulmonary bypass
    • Hargrove M, O'Donnell A, Aherne T: Differences in displayed pump flow compared to measured flow under varying conditions during simulated cardiopulmonary bypass. Perfusion 23: 227-230, 2008.
    • (2008) Perfusion , vol.23 , pp. 227-230
    • Hargrove, M.1    O'Donnell, A.2    Aherne, T.3
  • 7
    • 33747607967 scopus 로고    scopus 로고
    • Non-occlusive condition with the better-header roller pump: Impacts of flow dynamics and hemolysis
    • Tayama E, Teshima H, Takaseya T, et al: Non-occlusive condition with the better-header roller pump: Impacts of flow dynamics and hemolysis. Ann Thorac Cardiovasc Surg 10: 357-361, 2004.
    • (2004) Ann Thorac Cardiovasc Surg , vol.10 , pp. 357-361
    • Tayama, E.1    Teshima, H.2    Takaseya, T.3
  • 8
    • 0343488539 scopus 로고    scopus 로고
    • A dynamic method for setting roller pumps nonocclusively reduces hemolysis and predicts retrograde flow
    • Tamari Y, Lee-Sensiba K, Leonard EF, Tortolani AJ: A dynamic method for setting roller pumps nonocclusively reduces hemolysis and predicts retrograde flow. ASAIO J 43: 39-52, 1997.
    • (1997) ASAIO J , vol.43 , pp. 39-52
    • Tamari, Y.1    Lee-Sensiba, K.2    Leonard, E.F.3    Tortolani, A.J.4
  • 9
    • 0031715260 scopus 로고    scopus 로고
    • Clinical evaluation by the dynamic method: Effect on flow
    • Mongero LB, Beck JR, Kroslowitz RM, et al: Clinical evaluation by the dynamic method: Effect on flow. Perfusion 13: 360-368, 1998.
    • (1998) Perfusion , vol.13 , pp. 360-368
    • Mongero, L.B.1    Beck, J.R.2    Kroslowitz, R.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.