메뉴 건너뛰기




Volumn 57, Issue 1, 2010, Pages 203-205

Standing-wave suppression for transcranial ultrasound by random modulation

Author keywords

Random frequency modulation; Standing wave suppression; Transcranial ultrasound

Indexed keywords

BLOOD-BRAIN BARRIER; BRAIN THERAPY; CONTINUOUS WAVES; CW EXCITATION; CW OPERATION; EX-VIVO; FREQUENCY CONTENTS; HUMAN SKULL; LOW FREQUENCY; LOWER FREQUENCIES; RANDOM FREQUENCY; RANDOM FREQUENCY MODULATION; RANDOM MODULATION; SINGLE-FREQUENCY; STANDING WAVE; SWEPT-FREQUENCY; TRANSCRANIAL; TRANSCRANIAL ULTRASOUND; TUMOR ABLATION; ULTRASOUND FIELDS;

EID: 76649127393     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBME.2009.2028653     Document Type: Article
Times cited : (34)

References (22)
  • 1
    • 33947125570 scopus 로고    scopus 로고
    • Clinical applications of focused ultrasound-The brain
    • K. Hynynen and G. Clement, "Clinical applications of focused ultrasound-The brain," Int. J. Hyperthermia, vol.23, no.2, pp. 193-202, 2007.
    • (2007) Int. J. Hyperthermia , vol.23 , Issue.2 , pp. 193-202
    • Hynynen, K.1    Clement, G.2
  • 2
    • 23044455788 scopus 로고    scopus 로고
    • A magnetic resonance imaging-compatible, large-scale array for transskull ultrasound surgery and therapy
    • G. T. Clement, P. J. White, R. L. King, N. McDannold, and K. Hynynen, "A magnetic resonance imaging-compatible, large-scale array for transskull ultrasound surgery and therapy," J. Ultrasound Med., vol.24, no.8, pp. 1117-1125, 2005.
    • (2005) J. Ultrasound Med , vol.24 , Issue.8 , pp. 1117-1125
    • Clement, G.T.1    White, P.J.2    King, R.L.3    McDannold, N.4    Hynynen, K.5
  • 3
    • 33746242230 scopus 로고    scopus 로고
    • Pre-clinical testing of a phased array ultrasound system for MRI-guided noninvasive surgery of the brain-A primate study
    • K. Hynynen, N. McDannold, G. Clement, F. A. Jolesz, E. Zadicario, R. Killiany, T. Moore, andD. Rosen, "Pre-clinical testing of a phased array ultrasound system for MRI-guided noninvasive surgery of the brain-A primate study," Eur. J. Radiol., vol.59, no.2, pp. 149-156, 2006.
    • (2006) Eur. J. Radiol. , vol.59 , Issue.2 , pp. 149-156
    • Hynynen, K.1    McDannold, N.2    Clement, G.3    Jolesz, F.A.4    Zadicario, E.5    Killiany, R.6    Moore, T.7    Rosen, D.8
  • 4
    • 0002771923 scopus 로고
    • Fundamental neurological research and human neurosurgery using intense ultrasound
    • W. J. Fry and F. J. Fry, "Fundamental neurological research and human neurosurgery using intense ultrasound," IRE Trans. Med. Electron., vol.ME-7, pp. 166-181, 1960.
    • (1960) IRE Trans. Med. Electron. , vol.ME-7 , pp. 166-181
    • Fry, W.J.1    Fry, F.J.2
  • 5
    • 3042548392 scopus 로고
    • Ultrasound in neurology
    • W. J. Fry, "Ultrasound in neurology," Neurology, vol.6, no.10, pp. 693- 704, 1956.
    • (1956) Neurology , vol.6 , Issue.10 , pp. 693-704
    • Fry, W.J.1
  • 6
    • 0036858483 scopus 로고    scopus 로고
    • Therapeutic ultrasound in ischemic stroke treatment: Experimental evidence
    • M.Daffertshofer andM. Fatar, "Therapeutic ultrasound in ischemic stroke treatment: Experimental evidence," Eur. J. Ultrasound, vol.16, no.1-2, pp. 121-130, 2002.
    • (2002) Eur. J. Ultrasound , vol.16 , Issue.1-2 , pp. 121-130
    • Daffertshofer, M.1    Fatar, M.2
  • 7
    • 34247860711 scopus 로고    scopus 로고
    • Acute stroke: Therapeutic transcranial Doppler sonography
    • R.Mikulik and A. V. Alexandrov, "Acute stroke: Therapeutic transcranial Doppler sonography," Front Neurol. Neurosci., vol.21, pp. 150-161, 2006.
    • (2006) Front Neurol. Neurosci , vol.21 , pp. 150-161
    • Mikulik, R.1    Alexandrov, A.V.2
  • 8
    • 34948871084 scopus 로고    scopus 로고
    • Ultrasound accelerates thrombolysis of acutely induced platelet-rich thrombi similar to those in acute myocardial infarction
    • H. Kawata, N. Naya, Y. Takemoto, S. Uemura, T. Nakajima, M. Horii, Y. Takeda, S. Fujimoto, A. Yamashita, Y. Asada, and Y. Saito, "Ultrasound accelerates thrombolysis of acutely induced platelet-rich thrombi similar to those in acute myocardial infarction," Circ. J., vol.71, no.10, pp. 1643- 1648, 2007.
    • (2007) Circ. J. , vol.71 , Issue.10 , pp. 1643-1648
    • Kawata, H.1    Naya, N.2    Takemoto, Y.3    Uemura, S.4    Nakajima, T.5    Horii, M.6    Takeda, Y.7    Fujimoto, S.8    Yamashita, A.9    Asada, Y.10    Saito, Y.11
  • 9
    • 0034876083 scopus 로고    scopus 로고
    • Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits
    • K. Hynynen, N. McDannold, N. Vykhodtseva, and F. A. Jolesz, "Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits," Radiology, vol.220, no.3, pp. 640-646, 2001.
    • (2001) Radiology , vol.220 , Issue.3 , pp. 640-646
    • Hynynen, K.1    McDannold, N.2    Vykhodtseva, N.3    Jolesz, F.A.4
  • 11
    • 0019504933 scopus 로고
    • Transkull focal lesions in cat brain produced by ultrasound
    • F. J. Fry, S. A. Goss, and J. T. Patrick, "Transkull focal lesions in cat brain produced by ultrasound," J. Neurosurg., vol.54, no.5, pp. 659-663, 1981.
    • (1981) J. Neurosurg , vol.54 , Issue.5 , pp. 659-663
    • Fry, F.J.1    Goss, S.A.2    Patrick, J.T.3
  • 13
    • 33748483260 scopus 로고    scopus 로고
    • Focal disruption of the blood-brain barrier due to 260-kHz ultrasound bursts: A method for molecular imaging and targeted drug delivery
    • K. Hynynen, N. McDannold, N. Vykhodtseva, S.Raymond, R.Weissleder, F. A. Jolesz, and N. Sheikov, "Focal disruption of the blood-brain barrier due to 260-kHz ultrasound bursts: A method for molecular imaging and targeted drug delivery," J. Neurosurg., vol.105, no.3, pp. 445-454, 2006.
    • (2006) J. Neurosurg , vol.105 , Issue.3 , pp. 445-454
    • Hynynen, K.1    McDannold, N.2    Vykhodtseva, N.3    Raymond, S.4    Weissleder, R.5    Jolesz, F.A.6    Sheikov, N.7
  • 14
    • 33744457309 scopus 로고    scopus 로고
    • Bubble generation by standing wave in water surrounded by cranium with transcranial ultrasonic beam
    • T. Azuma, K. Kawabata, S. Umemura, M. Ogihara, J. Kubota1, A. Sasaki, and H. Furuhata, "Bubble generation by standing wave in water surrounded by cranium with transcranial ultrasonic beam," Jpn. J. Appl. Phys., vol.44, pp. 4625-4630, 2005.
    • (2005) Jpn. J. Appl. Phys. , vol.44 , pp. 4625-4630
    • Azuma, T.1    Kawabata, K.2    Umemura, S.3    Ogihara, M.4    Kubotal, J.5    Sasaki, A.6    Furuhata, H.7
  • 15
    • 21644464396 scopus 로고    scopus 로고
    • Schlieren observation of therapeutic field in water surrounded by cranium radiated from 500 kHz ultrasonic sector transducer
    • T. Azuma, K. Kawabata, S. Umemura, M. Ogihara, J. Kubota, A. Sasaki, and H. Furuhata, "Schlieren observation of therapeutic field in water surrounded by cranium radiated from 500 kHz ultrasonic sector transducer," in Proc IEEE Ultrason. Symp., 2004, vol.2, pp. 1001-1004.
    • (2004) In Proc IEEE Ultrason. Symp , vol.2 , pp. 1001-1004
    • Azuma, T.1    Kawabata, K.2    Umemura, S.3    Ogihara, M.4    Kubota, J.5    Sasaki, A.6    Furuhata, H.7
  • 16
    • 22044441701 scopus 로고    scopus 로고
    • Transcranial lowfrequency ultrasound-mediated thrombolysis in brain ischemia: Increased risk of hemorrhage with combined ultrasound and tissue plasminogen activator. Results of a phase II clinical trial
    • M. Daffertshofer, A. Gass, P. Ringleb, M. Sitzer, U. Sliwka, T. Els, O. Sedlaczek, W. J. Koroshetz, and M. G. Hennerici, "Transcranial lowfrequency ultrasound-mediated thrombolysis in brain ischemia: Increased risk of hemorrhage with combined ultrasound and tissue plasminogen activator. Results of a phase II clinical trial," Stroke, vol.36, no.7, pp. 1441-1446, 2005.
    • (2005) Stroke , vol.36 , Issue.7 , pp. 1441-1446
    • Daffertshofer, M.1    Gass, A.2    Ringleb, P.3    Sitzer, M.4    Sliwka, U.5    Els, T.6    Sedlaczek, O.7    Koroshetz, W.J.8    Hennerici, M.G.9
  • 17
    • 27744594484 scopus 로고    scopus 로고
    • Ultrasound augmented thrombolysis
    • W. C. Culp and T. C. McCowan, "Ultrasound augmented thrombolysis," Curr. Med. Imag. Rev., vol.1, no.1, pp. 5-12, 2005.
    • (2005) Curr. Med. Imag. Rev. , vol.1 , Issue.1 , pp. 5-12
    • Culp, W.C.1    McCowan, T.C.2
  • 20
    • 26844546944 scopus 로고    scopus 로고
    • Chirp imaging vibroacoustography for removing the ultrasound standing wave artifact
    • Oct.
    • F. G. Mitri, J. F Greenleaf, and M. Fatemi, "Chirp imaging vibroacoustography for removing the ultrasound standing wave artifact," IEEE Trans. Med. Imag., vol.24, no.10, pp. 1249-1255, Oct. 2005.
    • (2005) IEEE Trans. Med. Imag. , vol.24 , Issue.10 , pp. 1249-1255
    • Mitri, F.G.1    Greenleaf, J.F.2    Fatemi, M.3
  • 21
    • 33846933118 scopus 로고    scopus 로고
    • Bubble-based acoustic radiation force using chirp insonation to reduce standing wave effects
    • T. N. Erpelding, K.W. Hollman, and M. O'Donnell, "Bubble-based acoustic radiation force using chirp insonation to reduce standing wave effects," Ultrasound Med. Biol., vol.33, no.2, pp. 263-269, 2007.
    • (2007) Ultrasound Med. Biol. , vol.33 , Issue.2 , pp. 263-269
    • Erpelding, T.N.1    Hollman, K.W.2    O'Donnell, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.