1
-
-
0028146915
-
Refinements in free flap breast reconstruction: The free bilateral deep inferior epigastric perforator flap anastomosed to the internal mammary artery
-
Blondeel P N., Boeckx W D. Refinements in free flap breast reconstruction: the free bilateral deep inferior epigastric perforator flap anastomosed to the internal mammary artery. Br J Plast Surg 1994 47 495-501
-
(1994)
Br J Plast Surg
, vol.47
, pp. 495-501
-
-
Blondeel, P.N.1
Boeckx, W.D.2
-
2
-
-
0028012822
-
Deep inferior epigastric perforator flap for breast reconstruction
-
Allen R J., Treece P. Deep inferior epigastric perforator flap for breast reconstruction. Ann Plast Surg 1994 32 32-38
-
(1994)
Ann Plast Surg
, vol.32
, pp. 32-38
-
-
Allen, R.J.1
Treece, P.2
-
3
-
-
0033119328
-
The sensate free superior gluteal artery perforator (S-GAP) flap: A valuable alternative in autologous breast reconstruction
-
Blondeel P N. The sensate free superior gluteal artery perforator (S-GAP) flap: a valuable alternative in autologous breast reconstruction. Br J Plast Surg 1999 52 185-193
-
(1999)
Br J Plast Surg
, vol.52
, pp. 185-193
-
-
Blondeel, P.N.1
-
4
-
-
0026638708
-
Free thin paraumbilical perforator-based flaps
-
Koshima I, Moriguchi T, Soeda S, Tanaka H, Umeda N. Free thin paraumbilical perforator-based flaps. Ann Plast Surg 1992 29 12-17
-
(1992)
Ann Plast Surg
, vol.29
, pp. 12-17
-
-
Koshima, I.1
Moriguchi, T.2
Soeda, S.3
Tanaka, H.4
Umeda, N.5
-
5
-
-
0030846349
-
The fate of the oblique abdominal muscles after free TRAM flap surgery
-
Blondeel N, Boeckx W D., Vanderstraeten G G. et al. The fate of the oblique abdominal muscles after free TRAM flap surgery. Br J Plast Surg 1997 50 315-321
-
(1997)
Br J Plast Surg
, vol.50
, pp. 315-321
-
-
Blondeel, N.1
Boeckx, W.D.2
Vanderstraeten, G.G.3
-
6
-
-
0030759519
-
The donor site morbidity of free DIEP flaps and free TRAM flaps for breast reconstruction
-
Blondeel N, Vanderstraeten G G., Monstrey S J. et al. The donor site morbidity of free DIEP flaps and free TRAM flaps for breast reconstruction. Br J Plast Surg 1997 50 322-330
-
(1997)
Br J Plast Surg
, vol.50
, pp. 322-330
-
-
Blondeel, N.1
Vanderstraeten, G.G.2
Monstrey, S.J.3
-
7
-
-
34547700418
-
A critical review of perioperative complications in 175 free deep inferior epigastric perforator flap breast reconstructions
-
Hofer S O., Damen T H., Mureau M A., Rakhorst H A., Roche N A. A critical review of perioperative complications in 175 free deep inferior epigastric perforator flap breast reconstructions. Ann Plast Surg 2007 59 137-142
-
(2007)
Ann Plast Surg
, vol.59
, pp. 137-142
-
-
Hofer, S.O.1
Damen, T.H.2
Mureau, M.A.3
Rakhorst, H.A.4
Roche, N.A.5
-
8
-
-
0033774585
-
A retrospective comparison of abdominal muscle strength following breast reconstruction with a free TRAM or DIEP flap
-
Futter C M., Webster M H., Hagen S, Mitchell S L. A retrospective comparison of abdominal muscle strength following breast reconstruction with a free TRAM or DIEP flap. Br J Plast Surg 2000 53 578-583
-
(2000)
Br J Plast Surg
, vol.53
, pp. 578-583
-
-
Futter, C.M.1
Webster, M.H.2
Hagen, S.3
Mitchell, S.L.4
-
9
-
-
0141906252
-
Do pre-operative abdominal exercises prevent post-operative donor site complications for women undergoing DIEP flap breast reconstruction? A two-centre, prospective randomized controlled trial
-
Futter C M., Weiler-Mithoff E, Hagen S et al. Do pre-operative abdominal exercises prevent post-operative donor site complications for women undergoing DIEP flap breast reconstruction? A two-centre, prospective randomized controlled trial. Br J Plast Surg 2003 56 674-683
-
(2003)
Br J Plast Surg
, vol.56
, pp. 674-683
-
-
Futter, C.M.1
Weiler-Mithoff, E.2
Hagen, S.3
-
10
-
-
0035146259
-
Postoperative morphine requirements of free TRAM and DIEP flaps
-
Evans GRD
-
Kroll S S., Sharma S, Koutz C et al, Evans GRD. Postoperative morphine requirements of free TRAM and DIEP flaps. Plast Reconstr Surg 2001 107 338-341
-
(2001)
Plast Reconstr Surg
, vol.107
, pp. 338-341
-
-
Kroll, S.S.1
Sharma, S.2
Koutz, C.3
-
11
-
-
76249084153
-
High satisfaction rates in women after DIEP flap breast reconstruction
-
November 24 (Epub ahead of print)
-
Damen T H., Timman R, Kunst E H. et al. High satisfaction rates in women after DIEP flap breast reconstruction. J Plast Reconstr Aesthet Surg 2008 November 24 (Epub ahead of print)
-
(2008)
J Plast Reconstr Aesthet Surg
-
-
Damen, T.H.1
Timman, R.2
Kunst, E.H.3
-
13
-
-
58249122266
-
Impact of regional referral centers for microsurgical breast reconstruction: The New England perforator flap program experience
-
Yueh J H., Slavin S A., Bar-Meir E D. et al. Impact of regional referral centers for microsurgical breast reconstruction: the New England perforator flap program experience. J Am Coll Surg 2009 208 246-254
-
(2009)
J Am Coll Surg
, vol.208
, pp. 246-254
-
-
Yueh, J.H.1
Slavin, S.A.2
Bar-Meir, E.D.3
-
14
-
-
33646591567
-
The deep inferior epigastric perforator flap for breast reconstruction, the learning curve explored
-
Busic V, Das-Gupta R, Mesic H, Begic A. The deep inferior epigastric perforator flap for breast reconstruction, the learning curve explored. J Plast Reconstr Aesthet Surg 2006 59 580-584
-
(2006)
J Plast Reconstr Aesthet Surg
, vol.59
, pp. 580-584
-
-
Busic, V.1
Das-Gupta, R.2
Mesic, H.3
Begic, A.4
-
15
-
-
76649092727
-
Preoperative planning for DIEP breast reconstruction: Early experience of the use of computerised tomography angiography with VoNavix 3D software for perforator navigation
-
August 15 (Epub ahead of print)
-
Pacifico M D., See M S., Cavale N et al. Preoperative planning for DIEP breast reconstruction: early experience of the use of computerised tomography angiography with VoNavix 3D software for perforator navigation. J Plast Reconstr Aesthet Surg 2008 August 15 (Epub ahead of print)
-
(2008)
J Plast Reconstr Aesthet Surg
-
-
Pacifico, M.D.1
See, M.S.2
Cavale, N.3
-
16
-
-
0031919750
-
Doppler flowmetry in the planning of perforator flaps
-
Blondeel P N., Beyens G, Verhaeghe R et al. Doppler flowmetry in the planning of perforator flaps. Br J Plast Surg 1998 51 202-209
-
(1998)
Br J Plast Surg
, vol.51
, pp. 202-209
-
-
Blondeel, P.N.1
Beyens, G.2
Verhaeghe, R.3
-
17
-
-
76649134170
-
-
Surgical-technical aspects of the free DIEP flap for breast reconstruction In: Blondeel PN SM, Hallock GG, Neligan PC St. Louis, MO Quality Medical Publishers 1st ed
-
Blondeel P N., Landuyt K V., Monstrey S. Surgical-technical aspects of the free DIEP flap for breast reconstruction In: Blondeel PN SM, Hallock GG, Neligan PC Perforator flaps: anatomy, techniques and clinical applications. 1st ed. St. Louis, MO Quality Medical Publishers 2006 627-637
-
(2006)
Perforator Flaps: Anatomy, Techniques and Clinical Applications
, pp. 627-637
-
-
Blondeel, P.N.1
Landuyt, K.V.2
Monstrey, S.3
-
18
-
-
33645410090
-
-
St. Louis, MO Quality Medical Publications 1st ed
-
Blondeel P N., Hallock G G., Neligan P C. Perforator Flaps: Anatomy, Techniques, and Clinical Applications. 1st ed. St. Louis, MO Quality Medical Publications 2006
-
(2006)
Perforator Flaps: Anatomy, Techniques, and Clinical Applications
-
-
Blondeel, P.N.1
Hallock, G.G.2
Neligan, P.C.3
-
19
-
-
53149128386
-
Impact of perforator mapping using multidetector-row computed tomographic angiography on free thoracodorsal artery perforator flap transfer
-
Mun G H., Kim H J., Cha M K., Kim W Y. Impact of perforator mapping using multidetector-row computed tomographic angiography on free thoracodorsal artery perforator flap transfer. Plast Reconstr Surg 2008 122 1079-1088
-
(2008)
Plast Reconstr Surg
, vol.122
, pp. 1079-1088
-
-
Mun, G.H.1
Kim, H.J.2
Cha, M.K.3
Kim, W.Y.4
-
20
-
-
22944447126
-
Duplex ultrasound imaging in free transverse rectus abdominis muscle, deep inferior epigastric artery perforator, and superior gluteal artery perforator flaps: Early and long-term comparison of perfusion changes in free flaps following breast reconstruction
-
Heitland A S., Markowicz M, Koellensperger E, Schoth F, Feller A M., Pallua N. Duplex ultrasound imaging in free transverse rectus abdominis muscle, deep inferior epigastric artery perforator, and superior gluteal artery perforator flaps: early and long-term comparison of perfusion changes in free flaps following breast reconstruction. Ann Plast Surg 2005 55 117-121
-
(2005)
Ann Plast Surg
, vol.55
, pp. 117-121
-
-
Heitland, A.S.1
Markowicz, M.2
Koellensperger, E.3
Schoth, F.4
Feller, A.M.5
Pallua, N.6
-
21
-
-
53149138580
-
The accuracy of computed tomographic angiography for mapping the perforators of the deep inferior epigastric artery: A blinded, prospective cohort study
-
Rozen W M., Ashton M W., Stella D L., Phillips T J., Grinsell D, Taylor G I. The accuracy of computed tomographic angiography for mapping the perforators of the deep inferior epigastric artery: a blinded, prospective cohort study. Plast Reconstr Surg 2008 122 1003-1009
-
(2008)
Plast Reconstr Surg
, vol.122
, pp. 1003-1009
-
-
Rozen, W.M.1
Ashton, M.W.2
Stella, D.L.3
Phillips, T.J.4
Grinsell, D.5
Taylor, G.I.6
-
22
-
-
0028345993
-
Color-flow duplex scanning in the preoperative assessment of TRAM flap perforators: A report of 32 consecutive patients
-
Rand R P., Cramer M M., Strandness D E. Jr. Color-flow duplex scanning in the preoperative assessment of TRAM flap perforators: a report of 32 consecutive patients. Plast Reconstr Surg 1994 93 453-459
-
(1994)
Plast Reconstr Surg
, vol.93
, pp. 453-459
-
-
Rand, R.P.1
Cramer, M.M.2
Strandness, Jr.D.E.3
-
23
-
-
0027976539
-
Two-dimensional color Doppler imaging for precision preoperative mapping and size determination of TRAM flap perforators
-
Chang B W., Luethke R, Berg W A., Hamper U M., Manson P N. Two-dimensional color Doppler imaging for precision preoperative mapping and size determination of TRAM flap perforators. Plast Reconstr Surg 1994 93 197-200
-
(1994)
Plast Reconstr Surg
, vol.93
, pp. 197-200
-
-
Chang, B.W.1
Luethke, R.2
Berg, W.A.3
Hamper, U.M.4
Manson, P.N.5
-
24
-
-
0028030032
-
Evaluation of fasciocutaneous perforators using color duplex imaging
-
Hallock G G. Evaluation of fasciocutaneous perforators using color duplex imaging. Plast Reconstr Surg 1994 94 644-651
-
(1994)
Plast Reconstr Surg
, vol.94
, pp. 644-651
-
-
Hallock, G.G.1
-
25
-
-
0038149253
-
Doppler sonography and color duplex imaging for planning a perforator flap
-
vvi
-
Hallock G G. Doppler sonography and color duplex imaging for planning a perforator flap. Clin Plast Surg 2003 30 347-357 vvi
-
(2003)
Clin Plast Surg
, vol.30
, pp. 347-357
-
-
Hallock, G.G.1
-
26
-
-
0025273881
-
The Doppler probe for planning flaps: Anatomical study and clinical applications
-
Taylor G I., Doyle M, McCarten G. The Doppler probe for planning flaps: anatomical study and clinical applications. Br J Plast Surg 1990 43 1-16
-
(1990)
Br J Plast Surg
, vol.43
, pp. 1-16
-
-
Taylor, G.I.1
Doyle, M.2
McCarten, G.3
-
27
-
-
43149123780
-
Surgical technique in pedicled thoracodorsal artery perforator flaps: A clinical experience with 99 patients
-
Hamdi M, Van Landuyt K, Hijjawi J B., Roche N, Blondeel P, Monstrey S. Surgical technique in pedicled thoracodorsal artery perforator flaps: a clinical experience with 99 patients. Plast Reconstr Surg 2008 121 1632-1641
-
(2008)
Plast Reconstr Surg
, vol.121
, pp. 1632-1641
-
-
Hamdi, M.1
Van Landuyt, K.2
Hijjawi, J.B.3
Roche, N.4
Blondeel, P.5
Monstrey, S.6
-
28
-
-
0033165931
-
The superior gluteal artery perforator flap: An additional tool in the treatment of sacral pressure sores
-
Verpaele A M., Blondeel P N., Van Landuyt K et al. The superior gluteal artery perforator flap: an additional tool in the treatment of sacral pressure sores. Br J Plast Surg 1999 52 385-391
-
(1999)
Br J Plast Surg
, vol.52
, pp. 385-391
-
-
Verpaele, A.M.1
Blondeel, P.N.2
Van Landuyt, K.3
-
29
-
-
76649145500
-
-
Voet DaMP Ultrasound evaluation of perforator vessels In: Blondeel PN, Hallock GG, Neligan PC St. Louis, MO Quality Medical Publications 1st ed
-
Voet DaMP. Ultrasound evaluation of perforator vessels In: Blondeel PN, Hallock GG, Neligan PC Perforator Flaps: Anatomy, Techniques, and Clinical Applications. 1st ed. St. Louis, MO Quality Medical Publications 2006 92-102
-
(2006)
Perforator Flaps: Anatomy, Techniques, and Clinical Applications
, pp. 92-102
-
-
-
30
-
-
33748709419
-
Free DIEAP and SGAP flap breast reconstruction after abdominal/gluteal liposuction
-
De Frene B, Van Landuyt K, Hamdi M et al. Free DIEAP and SGAP flap breast reconstruction after abdominal/gluteal liposuction. J Plast Reconstr Aesthet Surg 2006 59 1031-1036
-
(2006)
J Plast Reconstr Aesthet Surg
, vol.59
, pp. 1031-1036
-
-
De Frene, B.1
Van Landuyt, K.2
Hamdi, M.3
-
31
-
-
43149101601
-
DIEP flaps in women with abdominal scars: Are complication rates affected?
-
Parrett B M., Caterson S A., Tobias A M., Lee B T. DIEP flaps in women with abdominal scars: are complication rates affected? Plast Reconstr Surg 2008 121 1527-1531
-
(2008)
Plast Reconstr Surg
, vol.121
, pp. 1527-1531
-
-
Parrett, B.M.1
Caterson, S.A.2
Tobias, A.M.3
Lee, B.T.4
-
32
-
-
0033767118
-
Venous congestion and blood flow in free transverse rectus abdominis myocutaneous and deep inferior epigastric perforator flaps
-
Blondeel P N., Arnstein M, Verstraete K et al. Venous congestion and blood flow in free transverse rectus abdominis myocutaneous and deep inferior epigastric perforator flaps. Plast Reconstr Surg 2000 106 1295-1299
-
(2000)
Plast Reconstr Surg
, vol.106
, pp. 1295-1299
-
-
Blondeel, P.N.1
Arnstein, M.2
Verstraete, K.3
-
33
-
-
67649390848
-
The efficacy of preoperative mapping of perforators in reducing operative times and complications in perforator flap breast reconstruction
-
Uppal R S., Casaer B, Van Landuyt K et al. The efficacy of preoperative mapping of perforators in reducing operative times and complications in perforator flap breast reconstruction. J Plast Reconstr Aesthet Surg 2009 62 859-864
-
(2009)
J Plast Reconstr Aesthet Surg
, vol.62
, pp. 859-864
-
-
Uppal, R.S.1
Casaer, B.2
Van Landuyt, K.3
-
34
-
-
0034069213
-
Four multidetector-row helical CT: Image quality and volume coverage speed
-
Hu H, He H D., Foley W D., Fox S H. Four multidetector-row helical CT: image quality and volume coverage speed. Radiology 2000 215 55-62
-
(2000)
Radiology
, vol.215
, pp. 55-62
-
-
Hu, H.1
He, H.D.2
Foley, W.D.3
Fox, S.H.4
-
35
-
-
0348109355
-
Multidetector row computed tomography of the aorta and peripheral arteries
-
Lawler L P., Fishman E K. Multidetector row computed tomography of the aorta and peripheral arteries. Cardiol Clin 2003 21 607-629
-
(2003)
Cardiol Clin
, vol.21
, pp. 607-629
-
-
Lawler, L.P.1
Fishman, E.K.2
-
36
-
-
0036210278
-
Techniques for the detection of coronary atherosclerosis: Multi-detector row CT coronary angiography
-
Vogl T J., Abolmaali N D., Diebold T et al. Techniques for the detection of coronary atherosclerosis: multi-detector row CT coronary angiography. Radiology 2002 223 212-220
-
(2002)
Radiology
, vol.223
, pp. 212-220
-
-
Vogl, T.J.1
Abolmaali, N.D.2
Diebold, T.3
-
37
-
-
0037432175
-
Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction
-
Ropers D, Baum U, Pohle K et al. Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 2003 107 664-666
-
(2003)
Circulation
, vol.107
, pp. 664-666
-
-
Ropers, D.1
Baum, U.2
Pohle, K.3
-
38
-
-
2342638270
-
Multidetector-row computed tomography and magnetic resonance imaging of atherosclerotic lesions in human ex vivo coronary arteries
-
Nikolaou K, Becker C R., Muders M et al. Multidetector-row computed tomography and magnetic resonance imaging of atherosclerotic lesions in human ex vivo coronary arteries. Atherosclerosis 2004 174 243-252
-
(2004)
Atherosclerosis
, vol.174
, pp. 243-252
-
-
Nikolaou, K.1
Becker, C.R.2
Muders, M.3
-
39
-
-
64449087081
-
Recent developments in wide-detector cardiac computed tomography
-
Choi S I., George R T., Schuleri K H. et al. Recent developments in wide-detector cardiac computed tomography. Int J Cardiovasc Imaging 2009 25 (Suppl 1) 23-29
-
(2009)
Int J Cardiovasc Imaging
, vol.25
, Issue.SUPPL 1
, pp. 23-29
-
-
Choi, S.I.1
George, R.T.2
Schuleri, K.H.3
-
40
-
-
33646542026
-
Multidetector-row computed tomography in the planning of abdominal perforator flaps
-
Masia J, Clavero J A., Larrañaga J R., Alomar X, Pons G, Serret P. Multidetector-row computed tomography in the planning of abdominal perforator flaps. J Plast Reconstr Aesthet Surg 2006 59 594-599
-
(2006)
J Plast Reconstr Aesthet Surg
, vol.59
, pp. 594-599
-
-
Masia, J.1
Clavero, J.A.2
Larrañaga, J.R.3
Alomar, X.4
Pons, G.5
Serret, P.6
-
41
-
-
33646595996
-
Preoperative planning of deep inferior epigastric artery perforator flap reconstruction with multislice-CT angiography: Imaging findings and initial experience
-
Alonso-Burgos A, García-Tutor E, Bastarrika G, Cano D, Martínez-Cuesta A, Pina L J. Preoperative planning of deep inferior epigastric artery perforator flap reconstruction with multislice-CT angiography: imaging findings and initial experience. J Plast Reconstr Aesthet Surg 2006 59 585-593
-
(2006)
J Plast Reconstr Aesthet Surg
, vol.59
, pp. 585-593
-
-
Alonso-Burgos, A.1
García-Tutor, E.2
Bastarrika, G.3
Cano, D.4
Martínez-Cuesta, A.5
Pina, L.J.6
-
42
-
-
36448997426
-
3D CT angiography of abdominal wall vascular perforators to plan DIEAP flaps
-
Rosson G D., Williams C G., Fishman E K., Singh N K. 3D CT angiography of abdominal wall vascular perforators to plan DIEAP flaps. Microsurgery 2007 27 641-646
-
(2007)
Microsurgery
, vol.27
, pp. 641-646
-
-
Rosson, G.D.1
Williams, C.G.2
Fishman, E.K.3
Singh, N.K.4
-
43
-
-
39849105408
-
The value of the multidetector row computed tomography for the preoperative planning of deep inferior epigastric artery perforator flap: Our experience in 162 cases
-
Masia J, Larrañaga J, Clavero J A., Vives L, Pons G, Pons J M. The value of the multidetector row computed tomography for the preoperative planning of deep inferior epigastric artery perforator flap: our experience in 162 cases. Ann Plast Surg 2008 60 29-36
-
(2008)
Ann Plast Surg
, vol.60
, pp. 29-36
-
-
Masia, J.1
Larrañaga, J.2
Clavero, J.A.3
Vives, L.4
Pons, G.5
Pons, J.M.6
-
44
-
-
58149379526
-
Interindividual variability of the SIEA angiosome: Effects on operative strategies in breast reconstruction
-
Holm C, Mayr M, Höfter E, Raab N, Ninkovic M. Interindividual variability of the SIEA angiosome: effects on operative strategies in breast reconstruction. Plast Reconstr Surg 2008 122 1612-1620
-
(2008)
Plast Reconstr Surg
, vol.122
, pp. 1612-1620
-
-
Holm, C.1
Mayr, M.2
Höfter, E.3
Raab, N.4
Ninkovic, M.5
-
45
-
-
76649085594
-
Anatomic imaging of abdominal perforator flaps without ionizing radiation: Seeing is believing with magnetic resonance imaging angiography
-
May 18 (Epub ahead of print)
-
Greenspun D, Vasile J, Levine J L. et al. Anatomic imaging of abdominal perforator flaps without ionizing radiation: seeing is believing with magnetic resonance imaging angiography. J Reconstr Microsurg 2009 May 18 (Epub ahead of print)
-
(2009)
J Reconstr Microsurg
-
-
Greenspun, D.1
Vasile, J.2
Levine, J.L.3
|