메뉴 건너뛰기




Volumn 2009, Issue , 2009, Pages

Low-noise dynamic reconstruction for X-ray tomographic perfusion studies using low sampling rates

Author keywords

[No Author keywords available]

Indexed keywords

ATTENUATION CURVE; CT SYSTEM; CURRENT TECHNIQUES; DYNAMIC RECONSTRUCTION; FUNCTIONAL IMAGING; LOW NOISE; PERFUSION IMAGING; PERFUSION STUDIES; PROJECTION DATA; RECONSTRUCTED IMAGE; SAMPLING RATES; SINGLE SCAN; SMALL ANIMAL; TEMPORAL INTERPOLATION; TEMPORAL RESOLUTION; TEMPORAL SEQUENCES; TEMPORAL SMOOTHING; TOMOGRAPHIC; TOTAL DOSE; XRAY IMAGING;

EID: 76649083291     PISSN: 16874188     EISSN: 16874196     Source Type: Journal    
DOI: 10.1155/2009/108028     Document Type: Article
Times cited : (3)

References (18)
  • 3
    • 0035137614 scopus 로고    scopus 로고
    • Quantitative assessment of the ischemic brain by means of perfusion-related parameters derived from perfusion CT
    • Koenig M., Kraus M., Theek C., Klotz E., Gehlen W., Heuser L., Quantitative assessment of the ischemic brain by means of perfusion-related parameters derived from perfusion CT Stroke, vol. 32, no. 2, pp. 431-437, 2001.
    • (2001) Stroke , vol.32 , Issue.2 , pp. 431-437
    • Koenig, M.1    Kraus, M.2    Theek, C.3    Klotz, E.4    Gehlen, W.5    Heuser, L.6
  • 4
    • 0036327385 scopus 로고    scopus 로고
    • Comparison of admission perfusion computed tomography and qualitative diffusion- and perfusion-weighted magnetic resonance imaging in acute stroke patients
    • Wintermark M., Reichhart M., Cuisenaire O., Comparison of admission perfusion computed tomography and qualitative diffusion- and perfusion-weighted magnetic resonance imaging in acute stroke patients Stroke, vol. 33, no. 8, pp. 2025-2031, 2002.
    • (2002) Stroke , vol.33 , Issue.8 , pp. 2025-2031
    • Wintermark, M.1    Reichhart, M.2    Cuisenaire, O.3
  • 5
    • 3042595443 scopus 로고    scopus 로고
    • Comparison of perfusion computed tomography and computed tomography angiography source images with perfusion-weighted imaging and diffusion-weighted imaging in patients with acute stoke of less than 6 hours duration
    • Schramm P., Schellinger P. D., Klotz E., Comparison of perfusion computed tomography and computed tomography angiography source images with perfusion-weighted imaging and diffusion-weighted imaging in patients with acute stoke of less than 6 hours duration Stroke, vol. 35, no. 7, pp. 1652-1658, 2004.
    • (2004) Stroke , vol.35 , Issue.7 , pp. 1652-1658
    • Schramm, P.1    Schellinger, P.D.2    Klotz, E.3
  • 6
    • 34347368724 scopus 로고    scopus 로고
    • A temporal interpolation approach for dynamic reconstruction in perfusion CT
    • Montes P., Lauritsch G., A temporal interpolation approach for dynamic reconstruction in perfusion CT Medical Physics, vol. 34, no. 7, pp. 3077-3092, 2007.
    • (2007) Medical Physics , vol.34 , Issue.7 , pp. 3077-3092
    • Montes, P.1    Lauritsch, G.2
  • 8
    • 0001579379 scopus 로고
    • Equations for measuring blood flow by external monitoring of radioisotopes
    • Zierler K. L., Equations for measuring blood flow by external monitoring of radioisotopes Circulation Research, vol. 16, pp. 309-321, 1965.
    • (1965) Circulation Research , vol.16 , pp. 309-321
    • Zierler, K.L.1
  • 9
    • 34347374956 scopus 로고    scopus 로고
    • Heidelberg, Germany Interdisciplinary Center for Scientific Computing, Ruprecht-Karls-Universitt Heidelberg http://www.ub.uni-heidelberg.de/archiv/ 7020/
    • Montes P., Dynamic cone-beam reconstruction for perfusion computed tomography, Ph.D. thesis 2006 Heidelberg, Germany Interdisciplinary Center for Scientific Computing, Ruprecht-Karls-Universitt Heidelberg. http://www.ub.uni- heidelberg.de/archiv/7020/
    • (2006) Dynamic Cone-beam Reconstruction for Perfusion Computed Tomography, Ph.D. Thesis
    • Montes, P.1
  • 11
    • 0027542457 scopus 로고
    • B-spline signal processing: Part IIefficient design and applications
    • Unser M., Aldroubi A., Eden M., B-spline signal processing: part IIefficient design and applications IEEE Transactions on Signal Processing, vol. 41, no. 2, pp. 834-848, 1993.
    • (1993) IEEE Transactions on Signal Processing , vol.41 , Issue.2 , pp. 834-848
    • Unser, M.1    Aldroubi, A.2    Eden, M.3
  • 12
    • 0026910575 scopus 로고
    • Cardinal spline filters: Stability and convergence to the ideal sinc interpolator
    • Aldroubi A., Unser M., Eden M., Cardinal spline filters: stability and convergence to the ideal sinc interpolator Signal Processing, vol. 28, no. 2, pp. 127-138, 1992.
    • (1992) Signal Processing , vol.28 , Issue.2 , pp. 127-138
    • Aldroubi, A.1    Unser, M.2    Eden, M.3
  • 13
    • 34147137033 scopus 로고    scopus 로고
    • Self-similarity: Part Isplines and operators
    • Unser M., Blu T., Self-similarity: part Isplines and operators IEEE Transactions on Signal Processing, vol. 55, no. 4, pp. 1352-1363, 2007.
    • (2007) IEEE Transactions on Signal Processing , vol.55 , Issue.4 , pp. 1352-1363
    • Unser, M.1    Blu, T.2
  • 15
    • 0343340400 scopus 로고    scopus 로고
    • 3D cone-beam CT reconstruction for circular trajectories
    • Grass M., Khler Th., Proksa R., 3D cone-beam CT reconstruction for circular trajectories Physics in Medicine and Biology, vol. 45, no. 2, pp. 329-347, 2000.
    • (2000) Physics in Medicine and Biology , vol.45 , Issue.2 , pp. 329-347
    • Grass, M.1    Khler, Th.2    Proksa, R.3
  • 16
    • 0037036597 scopus 로고    scopus 로고
    • Theoretical framework for a dynamic cone-beam reconstruction algorithm based on a dynamic particle model
    • Grangeat P., Koenig A., Rodet T., Bonnet S., Theoretical framework for a dynamic cone-beam reconstruction algorithm based on a dynamic particle model Physics in Medicine and Biology, vol. 47, no. 15, pp. 2611-2625, 2002.
    • (2002) Physics in Medicine and Biology , vol.47 , Issue.15 , pp. 2611-2625
    • Grangeat, P.1    Koenig, A.2    Rodet, T.3    Bonnet, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.