-
1
-
-
0017738346
-
TQ-ST segment mapping: critical relead and analysis of current concepts
-
Holland R.P., and Brooks H. TQ-ST segment mapping: critical relead and analysis of current concepts. Am J Cardiol 40 (1977) 110
-
(1977)
Am J Cardiol
, vol.40
, pp. 110
-
-
Holland, R.P.1
Brooks, H.2
-
2
-
-
0033822124
-
Myocardial infarction redefined-a consensus document of The Joint European Society of Cardiology/American College of Cardiology Committee for the redefinition of myocardial infarction
-
Myocardial infarction redefined-a consensus document of The Joint European Society of Cardiology/American College of Cardiology Committee for the redefinition of myocardial infarction. Eur Heart J 21 (2000) 1502
-
(2000)
Eur Heart J
, vol.21
, pp. 1502
-
-
-
3
-
-
0034064704
-
Optimizing the initial 12-lead electrocardiographic diagnosis of acute myocardial infarction
-
Menown I.B.A., MacKenzie G., and Adgey A.A.J. Optimizing the initial 12-lead electrocardiographic diagnosis of acute myocardial infarction. Eur Heart J 21 (2000) 275
-
(2000)
Eur Heart J
, vol.21
, pp. 275
-
-
Menown, I.B.A.1
MacKenzie, G.2
Adgey, A.A.J.3
-
4
-
-
31144455844
-
Comparison of ST-segment deviation to scintigraphically quantified myocardial ischemia during acute coronary occlusion induced by percutaneous transluminal coronary angioplasty
-
Persson E., Pettersson J., Ringborn M., et al. Comparison of ST-segment deviation to scintigraphically quantified myocardial ischemia during acute coronary occlusion induced by percutaneous transluminal coronary angioplasty. Am J Cardiol 97 (2006) 295
-
(2006)
Am J Cardiol
, vol.97
, pp. 295
-
-
Persson, E.1
Pettersson, J.2
Ringborn, M.3
-
5
-
-
0029003106
-
Comparison using dynamic vectorcardiography and MIBI SPECT of ST-segment changes and myocardial MIBI uptake during percutaneous transluminal coronary angioplasty of the left anterior descending coronary artery
-
Steg P.G., Faraggi M., Himbert D., et al. Comparison using dynamic vectorcardiography and MIBI SPECT of ST-segment changes and myocardial MIBI uptake during percutaneous transluminal coronary angioplasty of the left anterior descending coronary artery. Am J Cardiol 75 (1995) 998
-
(1995)
Am J Cardiol
, vol.75
, pp. 998
-
-
Steg, P.G.1
Faraggi, M.2
Himbert, D.3
-
6
-
-
0030894375
-
Residual area at risk after anterior myocardial infarction: are ST-segment changes during coronary angioplasty a reliable indicator? A comparison with technetium 99m-labeled sestamibi single-photon emission computed tomography
-
Faraggi M., Steg P.G., Francois D., et al. Residual area at risk after anterior myocardial infarction: are ST-segment changes during coronary angioplasty a reliable indicator? A comparison with technetium 99m-labeled sestamibi single-photon emission computed tomography. J Nucl Cardiol 4 (1997) 11
-
(1997)
J Nucl Cardiol
, vol.4
, pp. 11
-
-
Faraggi, M.1
Steg, P.G.2
Francois, D.3
-
8
-
-
0036214945
-
Assessment of myocardium at risk with vectorcardiography and technetium-99m-sestamibi-single photon emission computed tomography during coronary angioplasty
-
Jensen S.M., Karp K., Rask P., and Näslund U. Assessment of myocardium at risk with vectorcardiography and technetium-99m-sestamibi-single photon emission computed tomography during coronary angioplasty. Scand Cardiovasc J 36 (2002) 11
-
(2002)
Scand Cardiovasc J
, vol.36
, pp. 11
-
-
Jensen, S.M.1
Karp, K.2
Rask, P.3
Näslund, U.4
-
9
-
-
0034883960
-
Extent of ST-segment deviation in the single ECG lead of maximum deviation present at 90 or 180 minutes after start of thrombolytic therapy best predicts outcome in acute myocardial infarction
-
Schröder K., Wegscheider K., Zeymer U., Neuhaus K.L., and Schröder R. Extent of ST-segment deviation in the single ECG lead of maximum deviation present at 90 or 180 minutes after start of thrombolytic therapy best predicts outcome in acute myocardial infarction. Z Kardiol 90 (2001) 557
-
(2001)
Z Kardiol
, vol.90
, pp. 557
-
-
Schröder, K.1
Wegscheider, K.2
Zeymer, U.3
Neuhaus, K.L.4
Schröder, R.5
-
10
-
-
0035802760
-
Extent of ST-segment deviation in a single electrocardiogram lead of maximum 90 min after thrombolysis as a predictor of medium-term mortality in acute myocardial infarction
-
Schröder K., Wegscheider K., Zeymer U., Tebbe U., and Schröder R. Extent of ST-segment deviation in a single electrocardiogram lead of maximum 90 min after thrombolysis as a predictor of medium-term mortality in acute myocardial infarction. Lancet 358 (2001) 1479
-
(2001)
Lancet
, vol.358
, pp. 1479
-
-
Schröder, K.1
Wegscheider, K.2
Zeymer, U.3
Tebbe, U.4
Schröder, R.5
-
11
-
-
33845673786
-
The value of both ST-segment and QRS complex changes during acute coronary occlusion for prediction of reperfusion-induced myocardial salvage in a canine model
-
Weston P., Johanson P., Schwartz L.M., Maynard C., Jennings R.B., and Wagner G.S. The value of both ST-segment and QRS complex changes during acute coronary occlusion for prediction of reperfusion-induced myocardial salvage in a canine model. J Electrocardiol 40 (2007) 19
-
(2007)
J Electrocardiol
, vol.40
, pp. 19
-
-
Weston, P.1
Johanson, P.2
Schwartz, L.M.3
Maynard, C.4
Jennings, R.B.5
Wagner, G.S.6
-
12
-
-
0023744058
-
Transient alterations of the QRS complex and the ST segment during percutaneous transluminal angioplasty of the left anterior descending coronary artery
-
Wagner N.B., Sevilla D.C., Krukoff M.W., et al. Transient alterations of the QRS complex and the ST segment during percutaneous transluminal angioplasty of the left anterior descending coronary artery. Am J Cardiol 62 (1988) 1038
-
(1988)
Am J Cardiol
, vol.62
, pp. 1038
-
-
Wagner, N.B.1
Sevilla, D.C.2
Krukoff, M.W.3
-
13
-
-
33847404836
-
Chapter 2: Acute ischaemic syndrome-the pre-infarction ischaemic syndrome
-
Sclarovsky S. (Ed), Martin Dunitz Ltd, London, UK
-
Sclarovsky S. Chapter 2: Acute ischaemic syndrome-the pre-infarction ischaemic syndrome. In: Sclarovsky S. (Ed). Electrocardiography of acute myocardial ischaemic syndromes (1999), Martin Dunitz Ltd, London, UK 45
-
(1999)
Electrocardiography of acute myocardial ischaemic syndromes
, pp. 45
-
-
Sclarovsky, S.1
-
14
-
-
0025018290
-
Electrocardiographic classification of acute myocardial ischemia
-
Sclarovsky S., Mager A., Kusniec J., et al. Electrocardiographic classification of acute myocardial ischemia. Isr J Med Sci 26 (1990) 525
-
(1990)
Isr J Med Sci
, vol.26
, pp. 525
-
-
Sclarovsky, S.1
Mager, A.2
Kusniec, J.3
-
15
-
-
0029872364
-
Prognostic significance of the admission electrocardiogram in acute myocardial infarction
-
Birnbaum Y., Herz I., Sclarovsky S., et al. Prognostic significance of the admission electrocardiogram in acute myocardial infarction. J Am Coll Cardiol 27 (1996) 1128
-
(1996)
J Am Coll Cardiol
, vol.27
, pp. 1128
-
-
Birnbaum, Y.1
Herz, I.2
Sclarovsky, S.3
-
16
-
-
0035370377
-
Prediction of the extent and severity of left ventricular dysfunction in anterior acute myocardial infarction by the admission electrocardiogram
-
Birnbaum Y., Criger D.A., Wagner G.S., et al. Prediction of the extent and severity of left ventricular dysfunction in anterior acute myocardial infarction by the admission electrocardiogram. Am Heart J 141 (2001) 915
-
(2001)
Am Heart J
, vol.141
, pp. 915
-
-
Birnbaum, Y.1
Criger, D.A.2
Wagner, G.S.3
-
17
-
-
0033391058
-
The initial electrocardiographic pattern in acute myocardial infarction: correlation with infarct size
-
Birnbaum Y., and Wagner G.S. The initial electrocardiographic pattern in acute myocardial infarction: correlation with infarct size. J Electrocardiol 32 Suppl (1999) 122
-
(1999)
J Electrocardiol
, vol.32
, Issue.SUPPL
, pp. 122
-
-
Birnbaum, Y.1
Wagner, G.S.2
-
18
-
-
0035887527
-
Comparison of primary coronary angioplasty versus thrombolysis in patients with ST segment elevation acute myocardial infarction and Grade II and Grade III myocardial ischemia on the enrolment electrocardiogram
-
Birnbaum Y., Goodman S.G., Barr A., et al. Comparison of primary coronary angioplasty versus thrombolysis in patients with ST segment elevation acute myocardial infarction and Grade II and Grade III myocardial ischemia on the enrolment electrocardiogram. Am J Cardiol 88 (2001) 842
-
(2001)
Am J Cardiol
, vol.88
, pp. 842
-
-
Birnbaum, Y.1
Goodman, S.G.2
Barr, A.3
-
19
-
-
0025186734
-
A spectral analysis of the high frequency QRS potentials observed during acute myocardial ischemia in dogs
-
Abboud S., Cohen R.J., and Sadeh D. A spectral analysis of the high frequency QRS potentials observed during acute myocardial ischemia in dogs. Int J Cardiol 26 (1990) 285
-
(1990)
Int J Cardiol
, vol.26
, pp. 285
-
-
Abboud, S.1
Cohen, R.J.2
Sadeh, D.3
-
20
-
-
0024307784
-
High frequency electrocardiography of three orthogonal leads in dogs during coronary artery occlusion
-
Abboud S., Smith J.M., Shargorodsky B., Laniado S., Sadeh D., and Cohen R.J. High frequency electrocardiography of three orthogonal leads in dogs during coronary artery occlusion. Pacing Clin Electrophysiol 12 (1989) 574
-
(1989)
Pacing Clin Electrophysiol
, vol.12
, pp. 574
-
-
Abboud, S.1
Smith, J.M.2
Shargorodsky, B.3
Laniado, S.4
Sadeh, D.5
Cohen, R.J.6
-
21
-
-
0023235819
-
Effects of coronary occlusion on high-frequency content of the epicardial electrocardiogram and body surface electrocardiogram
-
Mor-Avi V., Shargorodsky B., Abboud S., Laniado S., and Akselrod S. Effects of coronary occlusion on high-frequency content of the epicardial electrocardiogram and body surface electrocardiogram. Circulation 76 (1987) 237
-
(1987)
Circulation
, vol.76
, pp. 237
-
-
Mor-Avi, V.1
Shargorodsky, B.2
Abboud, S.3
Laniado, S.4
Akselrod, S.5
-
22
-
-
0023217652
-
Detection of transient myocardial ischemia by computer analysis of standard and signal-averaged high-frequency electrocardiograms in patients undergoing percutaneous transluminal coronary angioplasty
-
Abboud S., Cohen R.J., Selwyn A., Ganz P., Sadeh D., and Friedman P.L. Detection of transient myocardial ischemia by computer analysis of standard and signal-averaged high-frequency electrocardiograms in patients undergoing percutaneous transluminal coronary angioplasty. Circulation 76 (1987) 585
-
(1987)
Circulation
, vol.76
, pp. 585
-
-
Abboud, S.1
Cohen, R.J.2
Selwyn, A.3
Ganz, P.4
Sadeh, D.5
Friedman, P.L.6
-
23
-
-
0034669446
-
Changes in high-frequency QRS components are more sensitive than ST segment deviation for detecting acute coronary occlusion
-
Pettersson J., Pahlm O., Carro E., et al. Changes in high-frequency QRS components are more sensitive than ST segment deviation for detecting acute coronary occlusion. J Am Coll Cardiol 36 (2000) 1827
-
(2000)
J Am Coll Cardiol
, vol.36
, pp. 1827
-
-
Pettersson, J.1
Pahlm, O.2
Carro, E.3
-
24
-
-
0031806503
-
Electrocardiographic changes during prolonged coronary artery occlusion in man: comparison of standard and high-frequency recordings
-
Pettersson J., Lander P., Pahlm O., Sörnmo L., Warren S.G., and Wagner G.S. Electrocardiographic changes during prolonged coronary artery occlusion in man: comparison of standard and high-frequency recordings. Clin Physiol 18 (1998) 179
-
(1998)
Clin Physiol
, vol.18
, pp. 179
-
-
Pettersson, J.1
Lander, P.2
Pahlm, O.3
Sörnmo, L.4
Warren, S.G.5
Wagner, G.S.6
-
25
-
-
0028346623
-
High frequency QRS electrocardiography in the detection of reperfusion following thrombolytic therapy
-
Aversano T., Rudicoff B., Washington A., Traill S., Coombs V., and Raqueno J. High frequency QRS electrocardiography in the detection of reperfusion following thrombolytic therapy. Clin Cardiol 17 (1994) 175
-
(1994)
Clin Cardiol
, vol.17
, pp. 175
-
-
Aversano, T.1
Rudicoff, B.2
Washington, A.3
Traill, S.4
Coombs, V.5
Raqueno, J.6
-
26
-
-
0026150226
-
High frequency ECG during reperfusion therapy of acute myocardial infarction
-
Abboud S., Leor J., and Eldar M. High frequency ECG during reperfusion therapy of acute myocardial infarction. IEEE Comput Soc, Comput Cardiol (1990) 351
-
(1990)
IEEE Comput Soc, Comput Cardiol
, pp. 351
-
-
Abboud, S.1
Leor, J.2
Eldar, M.3
-
27
-
-
0024473776
-
99mTc-hexakis-2-methoxy-2-methylpropyl-isonitrile imaging for the assessment of myocardial area at risk and the effect of treatment in acute myocardial infarction
-
99mTc-hexakis-2-methoxy-2-methylpropyl-isonitrile imaging for the assessment of myocardial area at risk and the effect of treatment in acute myocardial infarction. Circulation 80 (1989) 1277
-
(1989)
Circulation
, vol.80
, pp. 1277
-
-
Gibbons, R.J.1
Verani, M.S.2
Behrenbeck, T.3
-
28
-
-
0027366693
-
Myocardial risk area defined by Tc-99m-sestamibi imaging during percutaneous transluminal coronary angioplasty: comparison with coronary angiography
-
Haronian H.L., Remetz M.S., Sinusas A.J., et al. Myocardial risk area defined by Tc-99m-sestamibi imaging during percutaneous transluminal coronary angioplasty: comparison with coronary angiography. J Am Coll Cardiol 22 (1993) 1033
-
(1993)
J Am Coll Cardiol
, vol.22
, pp. 1033
-
-
Haronian, H.L.1
Remetz, M.S.2
Sinusas, A.J.3
-
29
-
-
0013879798
-
A new system of multiple-lead exercise electrocardiography
-
Mason R.E., and Likar I. A new system of multiple-lead exercise electrocardiography. Am Heart J 71 (1966) 196
-
(1966)
Am Heart J
, vol.71
, pp. 196
-
-
Mason, R.E.1
Likar, I.2
-
32
-
-
0036100445
-
99mTc-sestamibi in patients undergoing prolonged coronary artery balloon occlusion
-
99mTc-sestamibi in patients undergoing prolonged coronary artery balloon occlusion. Nuclear Medicine Com 23 (2002) 219
-
(2002)
Nuclear Medicine Com
, vol.23
, pp. 219
-
-
Persson, E.1
Palmer, J.2
Pettersson, J.3
-
34
-
-
0025027892
-
Technical aspects of myocardial SPECT imaging with technetium-99m sestamibi
-
Garcia E.V., Cooke C.D., Van Train K.F., et al. Technical aspects of myocardial SPECT imaging with technetium-99m sestamibi. Am J Cardiol 66 (1990) 13
-
(1990)
Am J Cardiol
, vol.66
, pp. 13
-
-
Garcia, E.V.1
Cooke, C.D.2
Van Train, K.F.3
-
35
-
-
3543019748
-
Reduced high-frequency QRS components in patients with ischemic heart disease compared to normal subjects
-
Trägårdh E., Pahlm O., Wagner S.G., and Pettersson J. Reduced high-frequency QRS components in patients with ischemic heart disease compared to normal subjects. J Electrocardiol 37 (2004) 157
-
(2004)
J Electrocardiol
, vol.37
, pp. 157
-
-
Trägårdh, E.1
Pahlm, O.2
Wagner, S.G.3
Pettersson, J.4
-
36
-
-
0031773893
-
Decrease in the high frequency QRS components depending on the local conduction delay
-
Watanabe T., Yamaki M., Tachibana H., Kubota I., and Tomoike H. Decrease in the high frequency QRS components depending on the local conduction delay. Jpn Circ J 62 (1998) 844
-
(1998)
Jpn Circ J
, vol.62
, pp. 844
-
-
Watanabe, T.1
Yamaki, M.2
Tachibana, H.3
Kubota, I.4
Tomoike, H.5
-
37
-
-
0025853455
-
Simulation of high-resolution QRS complex using a ventricular model with a fractal conduction system. Effects of ischemia on high-frequency QRS potentials
-
Abboud S., Berenfeld O., and Sadeh D. Simulation of high-resolution QRS complex using a ventricular model with a fractal conduction system. Effects of ischemia on high-frequency QRS potentials. Circ Res 68 (1991) 1751
-
(1991)
Circ Res
, vol.68
, pp. 1751
-
-
Abboud, S.1
Berenfeld, O.2
Sadeh, D.3
-
38
-
-
33847411542
-
Reduced high-frequency QRS components in electrocardiogram leads facing an area of the heart with intraventricular conduction delay due to bundle branch block
-
Trägårdh E., Pettersson J., Wagner S.G., and Pahlm O. Reduced high-frequency QRS components in electrocardiogram leads facing an area of the heart with intraventricular conduction delay due to bundle branch block. J Electrocardiol 40 (2007) 127
-
(2007)
J Electrocardiol
, vol.40
, pp. 127
-
-
Trägårdh, E.1
Pettersson, J.2
Wagner, S.G.3
Pahlm, O.4
-
39
-
-
5144224573
-
Month-to-month and year-to-year reproducibility of high frequency QRS ECG signals
-
Batdorf N.J., Feiverson A.H., and Schlegel T.T. Month-to-month and year-to-year reproducibility of high frequency QRS ECG signals. J Electrocardiol 37 (2004) 289
-
(2004)
J Electrocardiol
, vol.37
, pp. 289
-
-
Batdorf, N.J.1
Feiverson, A.H.2
Schlegel, T.T.3
-
40
-
-
33744907027
-
Temporal and postural variation of 12-lead high-frequency QRS electrocardiographic signals in asymptomatic individuals
-
Douglas P.K., Batdorf N.J., Evans R.T., Feiveson A.H., Arenare B., and Schlegel T.T. Temporal and postural variation of 12-lead high-frequency QRS electrocardiographic signals in asymptomatic individuals. J Electrocardiol 39 (2006) 259
-
(2006)
J Electrocardiol
, vol.39
, pp. 259
-
-
Douglas, P.K.1
Batdorf, N.J.2
Evans, R.T.3
Feiveson, A.H.4
Arenare, B.5
Schlegel, T.T.6
|