메뉴 건너뛰기




Volumn 76, Issue 3 SUPPL., 2010, Pages

Accurate Accumulation of Dose for Improved Understanding of Radiation Effects in Normal Tissue

Author keywords

Deformation; Dose accumulation; Four dimensional; Informatics; Normal tissue effects

Indexed keywords

ADAPTIVE RADIOTHERAPY; BREATHING MOTIONS; CLINICAL OUTCOME; DOSE ACCUMULATION; DOSE DISTRIBUTIONS; IMAGE-BASED; INFORMATICS; MAPPING ALGORITHMS; NORMAL TISSUE; OPTIMAL SCHEDULE; PATIENT ANATOMY; RADIATION DOSE; RADIATION THERAPY; ROBUST METHODS; SEGMENTATION METHODS; TECHNICAL DEMANDS; TUMOR REGRESSION; UNCERTAINTY ESTIMATION;

EID: 76449113556     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2009.06.093     Document Type: Article
Times cited : (133)

References (44)
  • 3
    • 0033237777 scopus 로고    scopus 로고
    • A method to predict the effect of organ motion and set-up variations on treatment plans
    • Keall P.J., Beckham W.A., Booth J.T., et al. A method to predict the effect of organ motion and set-up variations on treatment plans. Australas Phys Eng Sci Med 22 (1999) 48-52
    • (1999) Australas Phys Eng Sci Med , vol.22 , pp. 48-52
    • Keall, P.J.1    Beckham, W.A.2    Booth, J.T.3
  • 4
    • 0033001374 scopus 로고    scopus 로고
    • A model to accumulate fractionated dose in a deforming organ
    • Yan D., Jaffray D.A., and Wong J.W. A model to accumulate fractionated dose in a deforming organ. Med Phys 44 (1999) 665
    • (1999) Med Phys , vol.44 , pp. 665
    • Yan, D.1    Jaffray, D.A.2    Wong, J.W.3
  • 5
    • 23244444205 scopus 로고    scopus 로고
    • The sensitivity of dose distributions for organ motion and set-up uncertainties in prostate IMRT
    • Bos L.J., van der Geer J., van Herk M., et al. The sensitivity of dose distributions for organ motion and set-up uncertainties in prostate IMRT. Radiother Oncol 76 (2005) 18-26
    • (2005) Radiother Oncol , vol.76 , pp. 18-26
    • Bos, L.J.1    van der Geer, J.2    van Herk, M.3
  • 6
    • 35448993585 scopus 로고    scopus 로고
    • Parotid gland dose in intensity-modulated radiotherapy for head and neck cancer: is what you plan what you get?
    • O'Daniel J.C., Garden A.S., Schwartz D.L., et al. Parotid gland dose in intensity-modulated radiotherapy for head and neck cancer: is what you plan what you get?. Int J Radiat Oncol Biol Phys 69 (2007) 1290-1296
    • (2007) Int J Radiat Oncol Biol Phys , vol.69 , pp. 1290-1296
    • O'Daniel, J.C.1    Garden, A.S.2    Schwartz, D.L.3
  • 9
    • 35548960398 scopus 로고    scopus 로고
    • Intensity-modulated radiation therapy for head and neck carcinoma
    • Gregoire V., De Neve W., Eisbruch A., et al. Intensity-modulated radiation therapy for head and neck carcinoma. Oncologist 12 (2007) 555-564
    • (2007) Oncologist , vol.12 , pp. 555-564
    • Gregoire, V.1    De Neve, W.2    Eisbruch, A.3
  • 10
    • 4744367365 scopus 로고    scopus 로고
    • Automated model-based organ delineation for radiotherapy planning in prostatic region
    • Pekar V., McNutt T.R., and Kaus M.R. Automated model-based organ delineation for radiotherapy planning in prostatic region. Int J Radiat Oncol Biol Phys 60 (2004) 973-980
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 973-980
    • Pekar, V.1    McNutt, T.R.2    Kaus, M.R.3
  • 11
    • 44349112873 scopus 로고    scopus 로고
    • Validation of a model-based segmentation approach to propagating normal anatomic regions of interest through the 10 phases of respiration
    • Ezhil M., Starkschall G., Mohan R., et al. Validation of a model-based segmentation approach to propagating normal anatomic regions of interest through the 10 phases of respiration. Int J Radiat Oncol Biol Phys 71 (2008) 900-906
    • (2008) Int J Radiat Oncol Biol Phys , vol.71 , pp. 900-906
    • Ezhil, M.1    Starkschall, G.2    Mohan, R.3
  • 12
    • 49549113402 scopus 로고    scopus 로고
    • Performance evaluation of automatic anatomy segmentation algorithm on repeat or four-dimensional computed tomography images using deformable image registration method
    • Wang H., Garden A.S., Zhang L., et al. Performance evaluation of automatic anatomy segmentation algorithm on repeat or four-dimensional computed tomography images using deformable image registration method. Int J Radiat Oncol Biol Phys 72 (2008) 210-219
    • (2008) Int J Radiat Oncol Biol Phys , vol.72 , pp. 210-219
    • Wang, H.1    Garden, A.S.2    Zhang, L.3
  • 13
    • 76449086748 scopus 로고    scopus 로고
    • A Standardized Nomenclature System for Head and Neck (H&N) IMRT Contouring, Planning and Quality Assurance
    • Kim J.J., Breen S.L., Aj W., et al. A Standardized Nomenclature System for Head and Neck (H&N) IMRT Contouring, Planning and Quality Assurance. Int J Radiat Oncol Biol Phys 70 (2007) S473
    • (2007) Int J Radiat Oncol Biol Phys , vol.70
    • Kim, J.J.1    Breen, S.L.2    Aj, W.3
  • 14
    • 0342588064 scopus 로고    scopus 로고
    • Selection and delineation of lymph node target volumes in head and neck conformal radiotherapy. Proposal for standardizing terminology and procedure based on the surgical experience
    • Gregoire V., Coche E., Cosnard G., et al. Selection and delineation of lymph node target volumes in head and neck conformal radiotherapy. Proposal for standardizing terminology and procedure based on the surgical experience. Radiother Oncol 56 (2000) 135-150
    • (2000) Radiother Oncol , vol.56 , pp. 135-150
    • Gregoire, V.1    Coche, E.2    Cosnard, G.3
  • 16
    • 0032706348 scopus 로고    scopus 로고
    • Dose calculations for external photon beams in radiotherapy
    • Ahnesjo A., and Aspradakis M.M. Dose calculations for external photon beams in radiotherapy. Phys Med Biol 44 (1999) R99-155
    • (1999) Phys Med Biol , vol.44
    • Ahnesjo, A.1    Aspradakis, M.M.2
  • 17
    • 0242521407 scopus 로고    scopus 로고
    • Monte Carlo modelling of external radiotherapy photon beams
    • Verhaegen F., and Seuntjens J. Monte Carlo modelling of external radiotherapy photon beams. Phys Med Biol 48 (2003) R107-R164
    • (2003) Phys Med Biol , vol.48
    • Verhaegen, F.1    Seuntjens, J.2
  • 18
    • 36649020653 scopus 로고    scopus 로고
    • Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning
    • Chetty I.J., Curran B., Cygler J.E., et al. Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning. Med Phys 34 (2007) 4818-4853
    • (2007) Med Phys , vol.34 , pp. 4818-4853
    • Chetty, I.J.1    Curran, B.2    Cygler, J.E.3
  • 19
    • 33845954132 scopus 로고    scopus 로고
    • Retrospective monte carlo dose calculations with limited beam weight information
    • Lindsay P.E., El Naqa I., Hope A.J., et al. Retrospective monte carlo dose calculations with limited beam weight information. Med Phys 34 (2007) 334-346
    • (2007) Med Phys , vol.34 , pp. 334-346
    • Lindsay, P.E.1    El Naqa, I.2    Hope, A.J.3
  • 20
    • 38849206914 scopus 로고    scopus 로고
    • Local Correlation Between Monte-Carlo Dose and Radiation-Induced Fibrosis in Lung Cancer Patients
    • Stroian G., Martens C., Souhami L., et al. Local Correlation Between Monte-Carlo Dose and Radiation-Induced Fibrosis in Lung Cancer Patients. Int J Radiat Oncol Biol Phys 70 (2008) 921-930
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , pp. 921-930
    • Stroian, G.1    Martens, C.2    Souhami, L.3
  • 21
    • 47149103824 scopus 로고    scopus 로고
    • Underestimation of low-dose radiation in treatment planning of intensity-modulated radiotherapy
    • Jang S.Y., Liu H.H., and Mohan R. Underestimation of low-dose radiation in treatment planning of intensity-modulated radiotherapy. Int J Radiat Oncol Biol Phys 71 (2008) 1537-1546
    • (2008) Int J Radiat Oncol Biol Phys , vol.71 , pp. 1537-1546
    • Jang, S.Y.1    Liu, H.H.2    Mohan, R.3
  • 22
    • 34548297608 scopus 로고    scopus 로고
    • A Monte Carlo model for out-of-field dose calculation from high-energy photon therapy
    • Kry S.F., Titt U., Followill D., et al. A Monte Carlo model for out-of-field dose calculation from high-energy photon therapy. Med Phys 34 (2007) 3489-3499
    • (2007) Med Phys , vol.34 , pp. 3489-3499
    • Kry, S.F.1    Titt, U.2    Followill, D.3
  • 23
    • 12844271279 scopus 로고    scopus 로고
    • Toxicity and outcome results of RTOG 9311: A phase I-II dose-escalation study using three-dimensional conformal radiotherapy in patients with inoperable non-small-cell lung carcinoma
    • Bradley J., Graham M.V., Winter K., et al. Toxicity and outcome results of RTOG 9311: A phase I-II dose-escalation study using three-dimensional conformal radiotherapy in patients with inoperable non-small-cell lung carcinoma. Int J Radiat Oncol Biol Phys 61 (2005) 318-328
    • (2005) Int J Radiat Oncol Biol Phys , vol.61 , pp. 318-328
    • Bradley, J.1    Graham, M.V.2    Winter, K.3
  • 24
    • 0031688620 scopus 로고    scopus 로고
    • Radiation pneumonitis as a function of mean lung dose: an analysis of pooled data of 540 patients
    • Kwa S.L.S., Lebesque J.V., Theuws J.C.M., et al. Radiation pneumonitis as a function of mean lung dose: an analysis of pooled data of 540 patients. Int J Radiat Oncol Biol Phys 42 (1998) 1-9
    • (1998) Int J Radiat Oncol Biol Phys , vol.42 , pp. 1-9
    • Kwa, S.L.S.1    Lebesque, J.V.2    Theuws, J.C.M.3
  • 25
    • 0025939587 scopus 로고
    • Tolerance of normal tissue to therapeutic irradiation
    • Emami B., Lyman J., Brown A., et al. Tolerance of normal tissue to therapeutic irradiation. Int J Radiat Oncol Biol Phys 21 (1991) 109-122
    • (1991) Int J Radiat Oncol Biol Phys , vol.21 , pp. 109-122
    • Emami, B.1    Lyman, J.2    Brown, A.3
  • 26
    • 76449089386 scopus 로고    scopus 로고
    • Statistical Modelling of Tumor Control Probability for Non-small-cell Lung Cancer Radiotherapy
    • Mu Y., Hope A., Lindsay P., et al. Statistical Modelling of Tumor Control Probability for Non-small-cell Lung Cancer Radiotherapy. Int J Radiat Oncol Biol Phys 72 (2008) S448
    • (2008) Int J Radiat Oncol Biol Phys , vol.72
    • Mu, Y.1    Hope, A.2    Lindsay, P.3
  • 28
    • 56749158943 scopus 로고    scopus 로고
    • Objective Assessment of Deformable Image Registration in Radiotherapy: A Multi-Institutional Study
    • Kashani R., Hub M., Balter J., et al. Objective Assessment of Deformable Image Registration in Radiotherapy: A Multi-Institutional Study. Med Phys 35 (2008) 5944-5953
    • (2008) Med Phys , vol.35 , pp. 5944-5953
    • Kashani, R.1    Hub, M.2    Balter, J.3
  • 29
    • 43449120877 scopus 로고    scopus 로고
    • A Multi-Institution Deformable Registration Accuracy Study
    • Brock K.K. A Multi-Institution Deformable Registration Accuracy Study. Int J Radiat Oncol Biol Phys (Abstract) 69 (2007) S44
    • (2007) Int J Radiat Oncol Biol Phys (Abstract) , vol.69
    • Brock, K.K.1
  • 30
    • 23944489820 scopus 로고    scopus 로고
    • Dose reconstruction in deforming lung anatomy: dose grid size effects and clinical implications
    • Rosu M., Chetty I.J., Balter J.M., et al. Dose reconstruction in deforming lung anatomy: dose grid size effects and clinical implications. Med Phys 32 (2005) 2487-2495
    • (2005) Med Phys , vol.32 , pp. 2487-2495
    • Rosu, M.1    Chetty, I.J.2    Balter, J.M.3
  • 31
    • 17844379967 scopus 로고    scopus 로고
    • Respiratory correlated cone beam CT
    • Sonke J.J., Zijp L., Remeijer P., et al. Respiratory correlated cone beam CT. Med Phys 32 (2005) 1176-1186
    • (2005) Med Phys , vol.32 , pp. 1176-1186
    • Sonke, J.J.1    Zijp, L.2    Remeijer, P.3
  • 32
    • 4544360914 scopus 로고    scopus 로고
    • Integrating a MRI scanner with a 6 MV radiotherapy accelerator: dose deposition in a transverse magnetic field
    • Raaymakers B.W., Raaijmakers A.J., Kotte A.N., et al. Integrating a MRI scanner with a 6 MV radiotherapy accelerator: dose deposition in a transverse magnetic field. Phys Med Biol 49 (2004) 4109-4118
    • (2004) Phys Med Biol , vol.49 , pp. 4109-4118
    • Raaymakers, B.W.1    Raaijmakers, A.J.2    Kotte, A.N.3
  • 33
    • 33746814036 scopus 로고    scopus 로고
    • Tumor volume changes on serial imaging with megavoltage CT for non-small-cell lung cancer during intensity-modulated radiotherapy: How reliable, consistent, and meaningful is the effect?
    • Siker M.L., Tome W.A., and Mehta M.P. Tumor volume changes on serial imaging with megavoltage CT for non-small-cell lung cancer during intensity-modulated radiotherapy: How reliable, consistent, and meaningful is the effect?. Int J Radiat Oncol Biol Phys 66 (2006) 135-141
    • (2006) Int J Radiat Oncol Biol Phys , vol.66 , pp. 135-141
    • Siker, M.L.1    Tome, W.A.2    Mehta, M.P.3
  • 34
    • 27144468304 scopus 로고    scopus 로고
    • Serial megavoltage CT imaging during external beam radiotherapy for non-small-cell lung cancer: observations on tumor regression during treatment
    • Kupelian P.A., Ramsey C., Meeks S.L., et al. Serial megavoltage CT imaging during external beam radiotherapy for non-small-cell lung cancer: observations on tumor regression during treatment. Int J Radiat Oncol Biol Phys 63 (2005) 1024-1028
    • (2005) Int J Radiat Oncol Biol Phys , vol.63 , pp. 1024-1028
    • Kupelian, P.A.1    Ramsey, C.2    Meeks, S.L.3
  • 35
    • 4644290318 scopus 로고    scopus 로고
    • An implantable radiation dosimeter for use in external beam radiation therapy
    • Scarantino C.W., Ruslander D.M., Rini C.J., et al. An implantable radiation dosimeter for use in external beam radiation therapy. Med Phys 31 (2004) 2658-2671
    • (2004) Med Phys , vol.31 , pp. 2658-2671
    • Scarantino, C.W.1    Ruslander, D.M.2    Rini, C.J.3
  • 36
    • 17844367377 scopus 로고    scopus 로고
    • Suitability of radiochromic medium for real-time optical measurements of ionizing radiation dose
    • Rink A., Vitkin I.A., and Jaffray D.A. Suitability of radiochromic medium for real-time optical measurements of ionizing radiation dose. Med Phys 32 (2005) 1140-1155
    • (2005) Med Phys , vol.32 , pp. 1140-1155
    • Rink, A.1    Vitkin, I.A.2    Jaffray, D.A.3
  • 37
    • 0037394589 scopus 로고    scopus 로고
    • Optical-CT gel-dosimetry I: basic investigations
    • Oldham M., Siewerdsen J.H., Kumar S., et al. Optical-CT gel-dosimetry I: basic investigations. Med Phys 30 (2003) 623
    • (2003) Med Phys , vol.30 , pp. 623
    • Oldham, M.1    Siewerdsen, J.H.2    Kumar, S.3
  • 38
    • 0033819658 scopus 로고    scopus 로고
    • Radiation dosimetry using polymer gels: methods and applications
    • McJury M., Oldham M., Cosgrove V.P., et al. Radiation dosimetry using polymer gels: methods and applications. Br J Radiol 73 (2000) 919-929
    • (2000) Br J Radiol , vol.73 , pp. 919-929
    • McJury, M.1    Oldham, M.2    Cosgrove, V.P.3
  • 40
    • 22644443621 scopus 로고    scopus 로고
    • Carbon nanotubes for biomedical applications
    • Sinha N., and Yeow J.T. Carbon nanotubes for biomedical applications. IEEE Trans Nanobioscience 4 (2005) 180-195
    • (2005) IEEE Trans Nanobioscience , vol.4 , pp. 180-195
    • Sinha, N.1    Yeow, J.T.2
  • 41
    • 34347391909 scopus 로고    scopus 로고
    • Technical note: a physical phantom for assessment of accuracy of deformable alignment algorithms
    • Kashani R., Hub M., Kessler M.L., et al. Technical note: a physical phantom for assessment of accuracy of deformable alignment algorithms. Med Phys 34 (2007) 2785-2788
    • (2007) Med Phys , vol.34 , pp. 2785-2788
    • Kashani, R.1    Hub, M.2    Kessler, M.L.3
  • 42
    • 0032966188 scopus 로고    scopus 로고
    • The molecular and cellular basis of radiosensitivity: implications for understanding how normal tissues and tumors respond to therapeutic radiation
    • Rosen E.M., Fan S., Rockwell S., et al. The molecular and cellular basis of radiosensitivity: implications for understanding how normal tissues and tumors respond to therapeutic radiation. Cancer Invest 17 (1999) 56-72
    • (1999) Cancer Invest , vol.17 , pp. 56-72
    • Rosen, E.M.1    Fan, S.2    Rockwell, S.3
  • 43
    • 39749178409 scopus 로고    scopus 로고
    • From cellular to high-throughput predictive assays in radiation oncology: challenges and opportunities
    • Bentzen S.M. From cellular to high-throughput predictive assays in radiation oncology: challenges and opportunities. Semin Radiat Oncol 18 (2008) 75-88
    • (2008) Semin Radiat Oncol , vol.18 , pp. 75-88
    • Bentzen, S.M.1
  • 44
    • 32944454482 scopus 로고    scopus 로고
    • Discovering clinical biomarkers of ionizing radiation exposure with serum proteomic analysis
    • Menard C., Johann D., Lowenthal M., et al. Discovering clinical biomarkers of ionizing radiation exposure with serum proteomic analysis. Cancer Res 66 (2006) 1844-1850
    • (2006) Cancer Res , vol.66 , pp. 1844-1850
    • Menard, C.1    Johann, D.2    Lowenthal, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.