Volumn 22, Issue 2, 2010, Pages 277-282
|
Evaluation of mercury speciation and removal through air pollution control devices of a 190 MW boiler
|
Author keywords
air pollution control device; field testing; mercury removal; mercury speciation
|
Indexed keywords
AIR POLLUTANTS;
AIR POLLUTION CONTROL DEVICES;
COAL-FIRED POWER PLANT;
COAL-FIRED UTILITIES;
ELEMENTAL MERCURY;
FIELD TESTING;
MERCURY MASS BALANCE;
MERCURY REMOVAL;
MERCURY SPECIATIONS;
ONTARIO HYDRO METHODS;
OPERATIONAL CONDITIONS;
OXIDATION EFFICIENCY;
OXIDIZED MERCURY;
SAMPLING LOCATION;
TESTING DATA;
TOTAL MERCURIES;
U.S. ENVIRONMENTAL PROTECTION AGENCY;
WET FLUE GAS DESULFURIZATION;