메뉴 건너뛰기




Volumn 5, Issue 1, 2010, Pages 12-15

Sutureless aortic valve replacement via partial sternotomy

Author keywords

Aortic valve replacement; Bioprosthesis; Minimal invasive

Indexed keywords

AGED; AORTA CLAMPING; AORTA PROSTHESIS; AORTA VALVE REPLACEMENT; AORTA VALVE STENOSIS; ARTICLE; BIOPROSTHESIS; CARDIOPLEGIA; CARDIOPULMONARY BYPASS; CLINICAL ARTICLE; DEBRIDEMENT; ECHOCARDIOGRAPHY; FEMALE; FOLLOW UP; HUMAN; INTERMETHOD COMPARISON; MALE; PRIORITY JOURNAL; SCORING SYSTEM; STERNOTOMY; SURGICAL MORTALITY; SURGICAL TECHNIQUE;

EID: 76449096380     PISSN: 15569845     EISSN: 15590879     Source Type: Journal    
DOI: 10.1097/IMI.0b013e3181cdf6b1     Document Type: Article
Times cited : (20)

References (12)
  • 1
    • 0031461046 scopus 로고    scopus 로고
    • Minimal invasive cardiac valve surgery improves patient satisfaction while reducing costs of cardiac valve replacement and repair
    • Cohn LH, Adams DH, Couper GS, et al. Minimal invasive cardiac valve surgery improves patient satisfaction while reducing costs of cardiac valve replacement and repair. Ann Surg. 1997;226:421-428.
    • (1997) Ann Surg. , vol.226 , pp. 421-428
    • Cohn, L.H.1    Adams, D.H.2    Couper, G.S.3
  • 2
    • 0034532560 scopus 로고    scopus 로고
    • Aortic root replacement by ministernotomy: Technique and potential benefit
    • Sun L, Zheng J, Chang Q, et al. Aortic root replacement by ministernotomy: technique and potential benefit. Ann Thorac Surg. 2000;70: 1958-1961.
    • (2000) Ann Thorac Surg. , vol.70 , pp. 1958-1961
    • Sun, L.1    Zheng, J.2    Chang, Q.3
  • 3
    • 0036702152 scopus 로고    scopus 로고
    • Surgical results of aortic valve replacement via partial upper sternotomy: Comparison with median sternotomy
    • Masiello P, Coscioni E, Panza A, et al. Surgical results of aortic valve replacement via partial upper sternotomy: comparison with median sternotomy. Cardiovasc Surg. 2002;10:333-338.
    • (2002) Cardiovasc Surg. , vol.10 , pp. 333-338
    • Masiello, P.1    Coscioni, E.2    Panza, A.3
  • 4
    • 0037362104 scopus 로고    scopus 로고
    • Prospective comparison of minimally invasive and standard techniques for aortic valve replacement: Initial experience in the first hundred patients
    • Corbi P, Rahmati M, Donal E, et al. Prospective comparison of minimally invasive and standard techniques for aortic valve replacement: initial experience in the first hundred patients. J Card Surg. 2003;18: 133-139.
    • (2003) J Card Surg. , vol.18 , pp. 133-139
    • Corbi, P.1    Rahmati, M.2    Donal, E.3
  • 5
    • 0345700802 scopus 로고    scopus 로고
    • Chest pain after partial upper versus complete sternotomy for aortic valve surgery
    • Candaele S, Herijgers P, Demeyere R, et al. Chest pain after partial upper versus complete sternotomy for aortic valve surgery. Acta Cardiol. 2003;58:17-21.
    • (2003) Acta Cardiol. , vol.58 , pp. 17-21
    • Candaele, S.1    Herijgers, P.2    Demeyere, R.3
  • 6
    • 0037266564 scopus 로고    scopus 로고
    • Minimally invasive versus conventional aortic valve replacement: A prospective randomized trial
    • Dogan S, Dzemali O, Wimmer-Greinecker G, et al. Minimally invasive versus conventional aortic valve replacement: a prospective randomized trial. J Heart Valve Dis. 2003;12:76-80.
    • (2003) J Heart Valve Dis. , vol.12 , pp. 76-80
    • Dogan, S.1    Dzemali, O.2    Wimmer-Greinecker, G.3
  • 7
    • 40649115402 scopus 로고    scopus 로고
    • Early and late outcomes of 1000 minimally invasive aortic valve operations
    • Tabata M, Umakanthan R, Cohn LH, et al. Early and late outcomes of 1000 minimally invasive aortic valve operations. Eur J Cardiothorac Surg. 2008;33:537-541.
    • (2008) Eur J Cardiothorac Surg. , vol.33 , pp. 537-541
    • Tabata, M.1    Umakanthan, R.2    Cohn, L.H.3
  • 8
    • 23044500893 scopus 로고    scopus 로고
    • Tubular heart valves: A new tissue prosthesis design-preclinical evaluation of the 3f aortic bioprosthesis
    • Cox JL, Ad N, Myers K, et al. Tubular heart valves: a new tissue prosthesis design-preclinical evaluation of the 3f aortic bioprosthesis. J Thorac Cardiovasc Surg. 2005;130:520-527.
    • (2005) J Thorac Cardiovasc Surg. , vol.130 , pp. 520-527
    • Cox, J.L.1    Ad, N.2    Myers, K.3
  • 9
    • 13244287903 scopus 로고    scopus 로고
    • Aortic leaflet replacement with the new 3F stentless aortic bioprosthesis
    • Doss M, Martens S, Wood JP, et al. Aortic leaflet replacement with the new 3F stentless aortic bioprosthesis. Ann Thorac Surg. 2005;79:682-685.
    • (2005) Ann Thorac Surg. , vol.79 , pp. 682-685
    • Doss, M.1    Martens, S.2    Wood, J.P.3
  • 11
    • 0017182271 scopus 로고
    • The sutureless aortic valve prosthesis: Experience with and technical considerations for replacement of the early model
    • Scott SM, Sethi GK, Flye MW, Takaro T. The sutureless aortic valve prosthesis: experience with and technical considerations for replacement of the early model. Ann Surg. 1976;184:174-178.
    • (1976) Ann Surg. , vol.184 , pp. 174-178
    • Scott, S.M.1    Sethi, G.K.2    Flye, M.W.3    Takaro, T.4
  • 12
    • 40649127879 scopus 로고    scopus 로고
    • First clinical experiences and 1-year follow-up with the sutureless 3F-Enable aortic valve prosthesis
    • Wendt D, Thielmann M, Buck T, et al. First clinical experiences and 1-year follow-up with the sutureless 3F-Enable aortic valve prosthesis. Eur J Cardiothorac Surg. 2008;33:542-547.
    • (2008) Eur J Cardiothorac Surg. , vol.33 , pp. 542-547
    • Wendt, D.1    Thielmann, M.2    Buck, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.