메뉴 건너뛰기




Volumn 268, Issue 2, 2010, Pages 192-199

Determination of the 10Be half-life by multicollector ICP-MS and liquid scintillation counting

Author keywords

10Be half life; Liquid scintillation counting; Multicollector ICP MS

Indexed keywords

ACTIVITY CONCENTRATION; BIAS FACTOR; CATION CHROMATOGRAPHY; ERROR PROPAGATION; GLASS AMPOULES; ICP-MASS SPECTROMETRY; INDEPENDENT SET; LIQUID SCINTILLATION COUNTING; MC-ICP-MS; MEASUREMENT CONDITIONS; MULTI-COLLECTOR; MULTICOLLECTOR ICP-MS; RATIO STANDARD; SPACE CHARGE EFFECTS; STANDARD SOLUTIONS; STANDARD UNCERTAINTY;

EID: 76449087766     PISSN: 0168583X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.nimb.2009.09.012     Document Type: Article
Times cited : (801)

References (35)
  • 2
    • 34247519040 scopus 로고
    • Energy and half-life of the Be-10 radioactivity
    • McMillan E.M. Energy and half-life of the Be-10 radioactivity. Phys. Rev. 72 (1947) 591-593
    • (1947) Phys. Rev. , vol.72 , pp. 591-593
    • McMillan, E.M.1
  • 11
    • 34248202491 scopus 로고    scopus 로고
    • An inter-comparison of Be-10 and Al-26 AMS reference standards and the Be-10 half-life
    • Fink D., and Smith A. An inter-comparison of Be-10 and Al-26 AMS reference standards and the Be-10 half-life. Nucl. Instr. Meth. B 259 (2007) 600-609
    • (2007) Nucl. Instr. Meth. B , vol.259 , pp. 600-609
    • Fink, D.1    Smith, A.2
  • 12
    • 84867713522 scopus 로고    scopus 로고
    • A review of burial dating methods using 26Al and 10Be
    • Siame L.L., Bourles D.L., and Brown E.T. (Eds), Geological Society of America
    • Granger D.E. A review of burial dating methods using 26Al and 10Be. In: Siame L.L., Bourles D.L., and Brown E.T. (Eds). In situ-produced cosmogenic nuclides and quantification of geological processes (2006), Geological Society of America 1-16
    • (2006) In situ-produced cosmogenic nuclides and quantification of geological processes , pp. 1-16
    • Granger, D.E.1
  • 15
    • 24344490754 scopus 로고    scopus 로고
    • Cosmogenic nuclide evidence for low weathering and denudation in the wet, tropical highlands of Sri Lanka
    • von Blanckenburg F., Hewawasam T., and Kubik P.W. Cosmogenic nuclide evidence for low weathering and denudation in the wet, tropical highlands of Sri Lanka. J. Geophys. Res. Earth Surf. 109 (2004) F03008
    • (2004) J. Geophys. Res. Earth Surf. , vol.109
    • von Blanckenburg, F.1    Hewawasam, T.2    Kubik, P.W.3
  • 16
    • 0007237367 scopus 로고
    • Fractionation of the Li and K isotopes by chemical exchange with zeolites
    • Taylor Y.I., and Urey H.C. Fractionation of the Li and K isotopes by chemical exchange with zeolites. J. Chem. Phys. 6 (1938) 429-438
    • (1938) J. Chem. Phys. , vol.6 , pp. 429-438
    • Taylor, Y.I.1    Urey, H.C.2
  • 17
    • 0034616431 scopus 로고    scopus 로고
    • Nonbiological fractionation of iron isotopes
    • Anbar A.D., Roe J.E., Barling J., and Nealson K.H. Nonbiological fractionation of iron isotopes. Science 288 (2000) 126-128
    • (2000) Science , vol.288 , pp. 126-128
    • Anbar, A.D.1    Roe, J.E.2    Barling, J.3    Nealson, K.H.4
  • 18
    • 0031845241 scopus 로고    scopus 로고
    • High-yield lithium separation and the precise isotopic analysis for natural rock and aqueous samples
    • Moriguti T., and Nakamura E. High-yield lithium separation and the precise isotopic analysis for natural rock and aqueous samples. Chem. Geol. 145 (1998) 91-104
    • (1998) Chem. Geol. , vol.145 , pp. 91-104
    • Moriguti, T.1    Nakamura, E.2
  • 19
    • 0037402534 scopus 로고    scopus 로고
    • High precision Fe isotope measurements with high mass resolution MC-ICP-MS
    • Weyer S., and Schwieters J. High precision Fe isotope measurements with high mass resolution MC-ICP-MS. Int. J. Mass Spect. 226 (2003) 355-368
    • (2003) Int. J. Mass Spect. , vol.226 , pp. 355-368
    • Weyer, S.1    Schwieters, J.2
  • 20
    • 0000758476 scopus 로고
    • Non spectroscopic interelement interferences in inductively coupled plasma mass-spectrometry
    • Gillson G.R., Douglas D.J., Fulford J.E., Halligan K.W., and Tanner S.D. Non spectroscopic interelement interferences in inductively coupled plasma mass-spectrometry. Anal. Chem. 60 (1988) 1472-1474
    • (1988) Anal. Chem. , vol.60 , pp. 1472-1474
    • Gillson, G.R.1    Douglas, D.J.2    Fulford, J.E.3    Halligan, K.W.4    Tanner, S.D.5
  • 21
    • 0026875967 scopus 로고
    • Space-charge in ICP-MS - calculation and implications
    • Tanner S.D. Space-charge in ICP-MS - calculation and implications. Spectrochim. Acta Part B Atom. Spectr. 47 (1992) 809-823
    • (1992) Spectrochim. Acta Part B Atom. Spectr. , vol.47 , pp. 809-823
    • Tanner, S.D.1
  • 22
    • 0036026510 scopus 로고    scopus 로고
    • A simple method for obtaining highly accurate Pb isotope data by MC-ICP-MS
    • Woodhead J. A simple method for obtaining highly accurate Pb isotope data by MC-ICP-MS. J. Anal. Atom. Spect. 17 (2002) 1381-1385
    • (2002) J. Anal. Atom. Spect. , vol.17 , pp. 1381-1385
    • Woodhead, J.1
  • 24
    • 14844364318 scopus 로고    scopus 로고
    • An assessment of the accuracy of stable Fe isotope ratio measurements on samples with organic and inorganic matrices by high-resolution multicollector ICP-MS
    • Schoenberg R., and Von Blanckenburg F. An assessment of the accuracy of stable Fe isotope ratio measurements on samples with organic and inorganic matrices by high-resolution multicollector ICP-MS. Int. Journ. Mass Spect. 242 (2005) 257-272
    • (2005) Int. Journ. Mass Spect. , vol.242 , pp. 257-272
    • Schoenberg, R.1    Von Blanckenburg, F.2
  • 25
    • 0038681088 scopus 로고    scopus 로고
    • Precise analysis of copper and zinc isotopic compositions by plasma-source mass spectrometry
    • Marechal C.N., Telouk P., and Albarède F. Precise analysis of copper and zinc isotopic compositions by plasma-source mass spectrometry. Chem. Geol. 156 (1999) 251-273
    • (1999) Chem. Geol. , vol.156 , pp. 251-273
    • Marechal, C.N.1    Telouk, P.2    Albarède, F.3
  • 26
    • 37349098830 scopus 로고    scopus 로고
    • 203Tl normalization: optimization and calibration of the method for the studies of Pb isotope variations
    • 203Tl normalization: optimization and calibration of the method for the studies of Pb isotope variations. Chem. Int. 45 (2007) 1065-1076
    • (2007) Chem. Int. , vol.45 , pp. 1065-1076
    • Chernyshev, I.V.1    Chugaev, A.V.2    Shatagin, K.N.3
  • 27
    • 34547663294 scopus 로고    scopus 로고
    • Radionuclide metrology using liquid scintillation counting
    • Broda R., Cassette P., and Kossert K. Radionuclide metrology using liquid scintillation counting. Metrologia 44 (2007) S36-S52
    • (2007) Metrologia , vol.44
    • Broda, R.1    Cassette, P.2    Kossert, K.3
  • 28
    • 64049107135 scopus 로고    scopus 로고
    • Das Gasfüllzählrohr der PTB - eine Apparatur zur Bestimmung der Aktivität radioaktiver Gase
    • PTB-Ra-32, 1993, ISBN 3-89429-415-9
    • E.W. Günther, Das Gasfüllzählrohr der PTB - eine Apparatur zur Bestimmung der Aktivität radioaktiver Gase, PTB-Report PTB-Ra-32, 1993, ISBN 3-89429-415-9.
    • PTB-Report
    • Günther, E.W.1
  • 32
    • 26544479794 scopus 로고
    • The update to the atomic mass evaluation
    • Audi G., and Wapstra A.H. The update to the atomic mass evaluation. Nucl. Phys. A 59 1995 (1995) 409-480
    • (1995) Nucl. Phys. A , vol.59 , Issue.1995 , pp. 409-480
    • Audi, G.1    Wapstra, A.H.2
  • 34
    • 43049162775 scopus 로고    scopus 로고
    • Study of a Monte-Carlo rearrangement model for the activity determination of electron-capture nuclides by means of liquid scintillation counting
    • Kossert K., and Grau Carles A. Study of a Monte-Carlo rearrangement model for the activity determination of electron-capture nuclides by means of liquid scintillation counting. Appl. Radiat. Isot. 66 (2008) 998-1005
    • (2008) Appl. Radiat. Isot. , vol.66 , pp. 998-1005
    • Kossert, K.1    Grau Carles, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.