메뉴 건너뛰기




Volumn , Issue , 2009, Pages 2885-2891

Variable impedance magnetorheological clutch actuator and telerobotic implementation

Author keywords

[No Author keywords available]

Indexed keywords

CONTROL SYSTEM ARCHITECTURE; FORCE TRACKING; HIGH FREQUENCY HF; HUMAN SAFETY; IMPACT FORCE; LOS ALAMOS NATIONAL LABORATORY; MAGNETO-RHEOLOGICAL; MAGNETO-RHEOLOGICAL FLUID; MATERIALS DESIGN; OUTPUT FORCE; OUTPUT IMPEDANCE; ROBOTIC DEVICES; SINGLE DEGREE OF FREEDOMS; TORQUE TRACKING; VARIABLE IMPEDANCE;

EID: 76249131703     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IROS.2009.5354689     Document Type: Conference Paper
Times cited : (28)

References (15)
  • 1
    • 3042585047 scopus 로고    scopus 로고
    • A new actuation approach for human friendly robot design
    • M. Zinn, O. Khatib, and B. Roth, "A new actuation approach for human friendly robot design," ICRA 2004, no. 1, pp. 249 - 254, 2004.
    • (2004) ICRA 2004 , vol.1 , pp. 249-254
    • Zinn, M.1    Khatib, O.2    Roth, B.3
  • 2
    • 0011495416 scopus 로고    scopus 로고
    • Properties and applications of commercial magnetorheological fluids
    • M. R. Jolly, J. W. Bender, and J. D. Carlson, "Properties and applications of commercial magnetorheological fluids." J. of Intel. Mat. Sys. and Struct., vol. 10, no. 1, pp. 5 - 13, 1999.
    • (1999) J. of Intel. Mat. Sys. and Struct , vol.10 , Issue.1 , pp. 5-13
    • Jolly, M.R.1    Bender, J.W.2    Carlson, J.D.3
  • 3
    • 0029192692 scopus 로고
    • Series elastic actuators
    • G. A. Pratt and M. M. Williamson, "Series elastic actuators," IROS 1995, vol. 1, pp. 399 - 406, 1995.
    • (1995) IROS 1995 , vol.1 , pp. 399-406
    • Pratt, G.A.1    Williamson, M.M.2
  • 5
    • 34548671823 scopus 로고    scopus 로고
    • Maccepa, the mechanically adjustable compliance and controllable equilibrium position actuator: Design and implementation in a biped robot
    • R. Van Ham, B. Vanderborght, M. Van Damme, B. Verrelst, and D. Lefeber, "Maccepa, the mechanically adjustable compliance and controllable equilibrium position actuator: Design and implementation in a biped robot," Robot. Auton. Syst., vol. 55, no. 10, pp. 761-768, 2007.
    • (2007) Robot. Auton. Syst , vol.55 , Issue.10 , pp. 761-768
    • Van Ham, R.1    Vanderborght, B.2    Van Damme, M.3    Verrelst, B.4    Lefeber, D.5
  • 6
    • 51649093116 scopus 로고    scopus 로고
    • Vsa-ii: A novel prototype of variable stiffness actuator for safe and performing robots interacting with humans
    • May
    • R. Schiavi, G. Grioli, S. Sen, and A. Bicchi, "Vsa-ii: a novel prototype of variable stiffness actuator for safe and performing robots interacting with humans," ICRA 2008, pp. 2171-2176, May 2008.
    • (2008) ICRA 2008 , pp. 2171-2176
    • Schiavi, R.1    Grioli, G.2    Sen, S.3    Bicchi, A.4
  • 7
    • 76249089274 scopus 로고    scopus 로고
    • J. W. Hurst, J. Chestnutt, and A. Rizzi, An actuator with mechanically adjustable series compliance, Robotics Institute, Carnegie Mellon University, Pittsburgh, PA, Tech. Rep. CMU-RI-TR-04-24, Apr. 2004.
    • J. W. Hurst, J. Chestnutt, and A. Rizzi, "An actuator with mechanically adjustable series compliance," Robotics Institute, Carnegie Mellon University, Pittsburgh, PA, Tech. Rep. CMU-RI-TR-04-24, Apr. 2004.
  • 8
    • 0037265402 scopus 로고    scopus 로고
    • User-adaptive control of a magnetorheo-logical prosthetic knee
    • H. Herr and A. Wilkenfeld, "User-adaptive control of a magnetorheo-logical prosthetic knee." Ind. Robot, vol. 30, no. 1, pp. 42 - 55, 2003.
    • (2003) Ind. Robot , vol.30 , Issue.1 , pp. 42-55
    • Herr, H.1    Wilkenfeld, A.2
  • 10
    • 0346148677 scopus 로고    scopus 로고
    • Safe arm with mr-based passive compliant joints and visco-elastic covering for service robot applications
    • 3, Oct
    • S.-S. Yoon, S. Kang, S.-J. Kim, Y.-H. Kim, M. Kim, and C.-W. Lee, "Safe arm with mr-based passive compliant joints and visco-elastic covering for service robot applications," IROS 2003, vol. 3, pp. 2191-2196 vol.3, Oct. 2003.
    • (2003) IROS 2003 , vol.3 , pp. 2191-2196
    • Yoon, S.-S.1    Kang, S.2    Kim, S.-J.3    Kim, Y.-H.4    Kim, M.5    Lee, C.-W.6
  • 11
    • 36148997955 scopus 로고    scopus 로고
    • Development of normally closed type of magnetorheological clutch and its application to safe torque control system of human-collaborative robot
    • Dec
    • T. Saito and H. Ikeda, "Development of normally closed type of magnetorheological clutch and its application to safe torque control system of human-collaborative robot," J. of Intel. Mat. Sys. and Struct., vol. 18, no. 12, pp. 1181 - 1185, Dec. 2007.
    • (2007) J. of Intel. Mat. Sys. and Struct , vol.18 , Issue.12 , pp. 1181-1185
    • Saito, T.1    Ikeda, H.2
  • 12
    • 0041346438 scopus 로고    scopus 로고
    • Impedance control of a single shaft-type clutch using homogeneous electrorheological fluid
    • T. Nakamura, N. Saga, and M. Nakazawa, "Impedance control of a single shaft-type clutch using homogeneous electrorheological fluid," J. of Intel. Mat. Sys. and Struct., vol. 13, no. 7-8, pp. 465 - 469, 2002.
    • (2002) J. of Intel. Mat. Sys. and Struct , vol.13 , Issue.7-8 , pp. 465-469
    • Nakamura, T.1    Saga, N.2    Nakazawa, M.3
  • 15
    • 0003739390 scopus 로고
    • Engineering applications of fluids with a variable yield stress,
    • Ph.D. dissertation, UC Berkeley
    • R. W. Phillips, "Engineering applications of fluids with a variable yield stress," Ph.D. dissertation, UC Berkeley, 1969.
    • (1969)
    • Phillips, R.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.