메뉴 건너뛰기




Volumn 2, Issue , 2009, Pages 946-950

Lab-on-a-disk as a potential microfluidic platform for dengue NS1-ELISA

Author keywords

Centrifugal and capillary force; Dengue NS1 ELISA; Lab on a disk

Indexed keywords

96-MICROWELL; ANTIGEN-ANTIBODY INTERACTION; BIOSENSOR APPLICATIONS; CAPILLARY FORCE; CENTRIFUGAL FORCES; CURRENT TECHNIQUES; DENGUE VIRUS; DETECTION SYSTEM; EARLY DIAGNOSIS; ELISA ASSAY; FABRICATION PROCESS; HIGH SENSITIVITY; INCUBATION TIME; MICROFLUIDIC PLATFORMS; PASSIVE VALVES; ROTATION SPEED; SHORT DIFFUSION LENGTHS; SPECIFIC VOLUME; STRUCTURAL PROTEINS;

EID: 76249118919     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ISIEA.2009.5356330     Document Type: Conference Paper
Times cited : (18)

References (15)
  • 1
    • 33747184862 scopus 로고    scopus 로고
    • Serotype 1-specific monoclonal antibody-based antigen capture immunoassay for detection of circulating nonstructural protein NS1: Implications for early diagnosis and serotyping of dengue virus infections
    • May
    • H. Xu, B. Di, Y. Pan, L. Qiu, Y. Wang, and W. Hao et al., "Serotype 1-specific monoclonal antibody-based antigen capture immunoassay for detection of circulating nonstructural protein NS1: Implications for early diagnosis and serotyping of dengue virus infections," J. Clin. Microbiol. vol. 44, pp. 2872-2878, May 2006.
    • (2006) J. Clin. Microbiol. , vol.44 , pp. 2872-2878
    • Xu, H.1    Di, B.2    Pan, Y.3    Qiu, L.4    Wang, Y.5    Hao, W.6
  • 2
    • 33846837300 scopus 로고    scopus 로고
    • Evaluation of a commercial dengue NS1 antigen-capture ELISA for laboratory diagnosis of acute dengue virus infection
    • November
    • V. Kumarasamy, A.H. Abdul Wahab, S.K. Chua, Z. Hassan, Y.K. Chem, M. Mohamad, and K.B Chua. "Evaluation of a commercial dengue NS1 antigen-capture ELISA for laboratory diagnosis of acute dengue virus infection," J. Virol. Methods, vol. 140, pp. 75-79, November 2006.
    • (2006) J. Virol. Methods , vol.140 , pp. 75-79
    • Kumarasamy, V.1    Wahab, A.H.A.2    Chua, S.K.3    Hassan, Z.4    Chem, Y.K.5    Mohamad, M.6    Chua., K.B.7
  • 3
    • 0141961172 scopus 로고    scopus 로고
    • Enzyme linked immunosorbent assay on a microchip with electrochemical detection
    • J.S. Rossier and H.H. Girault, "Enzyme Linked Immunosorbent Assay on a Microchip with Electrochemical Detection," Lab on a Chip, vol. 1, pp. 153-157, 2001.
    • (2001) Lab on a Chip , vol.1 , pp. 153-157
    • Rossier, J.S.1    Girault, H.H.2
  • 4
    • 1842477057 scopus 로고    scopus 로고
    • Design of a Compact Disk-like Microfluidic Platform for Enzyme-Linked Immunosorbent Assay
    • DOI 10.1021/ac0348322
    • S. Lai, S. Wang, J. Luo, J. Lee, S.T. Yang, M.J. Madou. "Design of a Compact Disk-like Microfluidic Platform for Enzyme-Linked Immunosorbent Assay," Annal Chem vol. 76, pp. 1832-1837, 2004. (Pubitemid 38451496)
    • (2004) Analytical Chemistry , vol.76 , Issue.7 , pp. 1832-1837
    • Lai, S.1    Wang, S.2    Luo, J.3    Lee, L.J.4    Yang, S.-T.5    Madou, M.J.6
  • 5
    • 0034802331 scopus 로고    scopus 로고
    • Design and fabrication of CD-like microfluidic platforms for diagnostic: Mircofluidic functions
    • DOI 10.1023/A:1011419515576
    • M.J. Madou, L. J. Lee, S. Daunert, S. Lai, and C.H. Shih. "Design and Fabrication of CD-like Microfluidic Platforms for Diagnostics: Microfluidic Functions," Biomedical Microdevices vol. 3, no. 3, pp. 245-254, 2001. (Pubitemid 32899150)
    • (2001) Biomedical Microdevices , vol.3 , Issue.3 , pp. 245-254
    • Madou, M.J.1    Lee, L.J.2    Daunert, S.3    Lai, S.4    Shih, C.-H.5
  • 6
    • 31544452776 scopus 로고    scopus 로고
    • Read-out concepts for multiplexed bead-based fluorescence immunoassays on centrifugal microfluidic platforms
    • December
    • L. Riegger, M. Grumann, and T. Nann et. al."Read-out concepts for multiplexed bead-based fluorescence immunoassays on centrifugal microfluidic platforms," Sensors and Actuators vol. 126, no. 2006, pp. 455-462, December 2005.
    • (2005) Sensors and Actuators , vol.126 , Issue.2006 , pp. 455-462
    • Riegger, L.1    Grumann, M.2    Nann, T.3
  • 7
    • 0035193392 scopus 로고    scopus 로고
    • Design and fabrication of CD-like microfluidic platforms for diagnostics: Polymer-based microfabrication
    • DOI 10.1023/A:1012469017354
    • L.J. Lee, M.J. Madou, K.W. Koelling, S. Daunert, and S. Lai et al. "Design and fabrication of CD-like microfluidic platforms for diagnostics: Polymer-Based Microfabrication," Biomedical Microdevices, vol.3, no. 4, pp. 339-351, 2001. (Pubitemid 33103743)
    • (2001) Biomedical Microdevices , vol.3 , Issue.4 , pp. 339-351
    • Lee, L.J.1    Madou, M.J.2    Koelling, K.W.3    Daunert, S.4    Lai, S.5    Koh, C.G.6    Juang, Y.-J.7    Lu, Y.8    Yu, L.9
  • 8
    • 21544455278 scopus 로고    scopus 로고
    • UV laser machined polymer substrates for the development of microdiagnostic systems
    • M.A. Roberts, J.S. Rossier, P. Bercier, and H. Girault, "UV laser machined polymer substrates for the development of microdiagnostic systems," Anal. Chem., vol. 69, pp. 2035-2042, 1997.
    • (1997) Anal. Chem. , vol.69 , pp. 2035-2042
    • Roberts, M.A.1    Rossier, J.S.2    Bercier, P.3    Girault, H.4
  • 10
    • 33646877041 scopus 로고    scopus 로고
    • Integration of microcolumns and microfluidic fractionators on multitasking centrifugal microfluidic platform for the analysis of biomolecules
    • May
    • A. Elizabeth, Moschou, A. D. Nicholson, G. Jia, J.V. Zoval, and M.J. Madou et al., "Integration of microcolumns and microfluidic fractionators on multitasking centrifugal microfluidic platform for the analysis of biomolecules," Anal. Bioanal. Chem., vol. 385, pp. 596-605, May 2006.
    • (2006) Anal. Bioanal. Chem. , vol.385 , pp. 596-605
    • Elizabeth, A.1    Moschou2    Nicholson, A.D.3    Jia, G.4    Zoval, J.V.5    Madou, M.J.6
  • 11
    • 35448943929 scopus 로고    scopus 로고
    • Microimmunoanalysis on standard compact discs to determine low abundant compounds
    • S. Morais, J. Carracosa, D. Mira, R. Puchades, and A. Maquieira. "Microimmunoanalysis on standard compact discs to determine low abundant compounds," Anal. Chem., vol. 79, no. 20, pp. 7628-7635, 2007.
    • (2007) Anal. Chem. , vol.79 , Issue.20 , pp. 7628-7635
    • Morais, S.1    Carracosa, J.2    Mira, D.3    Puchades, R.4    Maquieira, A.5
  • 13
    • 33746558539 scopus 로고    scopus 로고
    • Fully integrated whole blood testing by real-time absorption measurement on a centrifugal platform
    • May
    • J. Steigert, M. Grumann, T. Brenner, L. Riegger, J. Harter, R. Zengerle and J. Ducree," Fully integrated whole blood testing by real-time absorption measurement on a centrifugal platform," Lab on a Chip, vol. 6, no. 8, pp. 1040-1044, May 2006.
    • (2006) Lab on a Chip , vol.6 , Issue.8 , pp. 1040-1044
    • Steigert, J.1    Grumann, M.2    Brenner, T.3    Riegger, L.4    Harter, J.5    Zengerle, R.6    Ducree, J.7
  • 15
    • 64049093709 scopus 로고    scopus 로고
    • Rapid nanoliter DNA hybridization based on reciprocating flow on a compact disk microfluidic device
    • March
    • C. Li, X. Dong, J. Qin, and B. Lin, "Rapid nanoliter DNA hybridization based on reciprocating flow on a compact disk microfluidic device," Analytica Chimica Acta vol. 640, pp. 93-99, March 2009.
    • (2009) Analytica Chimica Acta , vol.640 , pp. 93-99
    • Li, C.1    Dong, X.2    Qin, J.3    Lin, B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.