메뉴 건너뛰기




Volumn 112, Issue 2, 2010, Pages 449-454

Postoperative radiographic findings in patients undergoing intracranial electrode monitoring for medically refractory epilepsy: Clinical article

Author keywords

Complication; Computed tomography; Epilepsy; Intracranial monitoring; Subdural electrode

Indexed keywords

ADULT; ARTICLE; BONE GRAFT; BRAIN HEMORRHAGE; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; DECOMPRESSION SURGERY; ELECTRODE; EPILEPSY; FEMALE; HUMAN; MALE; PRIORITY JOURNAL;

EID: 76149129035     PISSN: 00223085     EISSN: 19330693     Source Type: Journal    
DOI: 10.3171/2009.7.JNS09838     Document Type: Article
Times cited : (10)

References (13)
  • 1
    • 35348908152 scopus 로고    scopus 로고
    • Subdural electrodeassociated complications: A 20-year experience
    • Fountas KN, Smith JR: Subdural electrodeassociated complications: a 20-year experience. Stereotact Funct Neurosurg 85:264-272, 2007
    • (2007) Stereotact Funct Neurosurg , vol.85 , pp. 264-272
    • Fountas, K.N.1    Smith, J.R.2
  • 3
    • 33845657464 scopus 로고    scopus 로고
    • Complications of invasive subdural electrode monitoring at St. Louis Children's Hospital, 1994-2005
    • Johnston JM, Mangano FT, Ojemann JG, Park TS, Trevathan E, Smyth MD: Complications of invasive subdural electrode monitoring at St. Louis Children's Hospital, 1994-2005. J Neurosurg 105:343-347, 2006
    • (2006) J Neurosurg , vol.105 , pp. 343-347
    • Johnston, J.M.1    Mangano, F.T.2    Ojemann, J.G.3    Park, T.S.4    Trevathan, E.5    Smyth, M.D.6
  • 4
    • 0034495091 scopus 로고    scopus 로고
    • Complications and results of subdural grid electrode implantation in epilepsy surgery
    • Lee WS, Lee JK, Lee SA, Kang JK, Ko TS: Complications and results of subdural grid electrode implantation in epilepsy surgery. Surg Neurol 54:346-351, 2000
    • (2000) Surg Neurol , vol.54 , pp. 346-351
    • Lee, W.S.1    Lee, J.K.2    Lee, S.A.3    Kang, J.K.4    Ko, T.S.5
  • 6
    • 0037404497 scopus 로고    scopus 로고
    • Complications of invasive subdural grid monitoring in children with epilepsy
    • Onal C, Otsubo H, Araki T, Chitoku S, Ochi A, Weiss S, et al: Complications of invasive subdural grid monitoring in children with epilepsy. J Neurosurg 98:1017-1026, 2003
    • (2003) J Neurosurg , vol.98 , pp. 1017-1026
    • Onal, C.1    Otsubo, H.2    Araki, T.3    Chitoku, S.4    Ochi, A.5    Weiss, S.6
  • 8
    • 0030200286 scopus 로고    scopus 로고
    • The safety and efficacy of chronically implanted subdural electrodes: A prospective study
    • Swartz BE, Rich JR, Dwan PS, DeSalles A, Kaufman MH, Walsh GO, et al: The safety and efficacy of chronically implanted subdural electrodes: a prospective study. Surg Neurol 46:87-93, 1996
    • (1996) Surg Neurol , vol.46 , pp. 87-93
    • Swartz, B.E.1    Rich, J.R.2    Dwan, P.S.3    DeSalles, A.4    Kaufman, M.H.5    Walsh, G.O.6
  • 9
    • 65849416717 scopus 로고    scopus 로고
    • Intracranial electroencephalography with subdural grid electrodes: Techniques, complications, and outcomes
    • Van Gompel JJ, Worrell GA, Bell ML, Patrick TA, Cascino GD, Raffel C, et al: Intracranial electroencephalography with subdural grid electrodes: techniques, complications, and outcomes. Neurosurgery 63:498-206, 2008
    • (2008) Neurosurgery , vol.63 , pp. 498-206
    • Van Gompel, J.J.1    Worrell, G.A.2    Bell, M.L.3    Patrick, T.A.4    Cascino, G.D.5    Raffel, C.6
  • 10
    • 76149122553 scopus 로고    scopus 로고
    • Intracranial monitoring
    • Winn HR, Youmans JR eds, ed 5. Philadelphia: Saunders
    • Vives K, Lee S, McCarthy K, Spencer D: Intracranial monitoring, in Winn HR, Youmans JR (eds): Youman's Neurological Surgery, ed 5. Philadelphia: Saunders, 2004, pp 2551-2563
    • (2004) Youman's Neurological Surgery , pp. 2551-2563
    • Vives, K.1    Lee, S.2    McCarthy, K.3    Spencer, D.4
  • 11
    • 0035797593 scopus 로고    scopus 로고
    • A randomized, controlled trial of surgery for temporallobe epilepsy
    • Effectiveness and Efficiency of Surgery for Temporal Lobe Epilepsy Study Group
    • Wiebe S, Blume WT, Girvin JP, Eliasziw M, Effectiveness and Efficiency of Surgery for Temporal Lobe Epilepsy Study Group: A randomized, controlled trial of surgery for temporallobe epilepsy. N Engl J Med 345:311-318, 2001
    • (2001) N Engl J Med , vol.345 , pp. 311-318
    • Wiebe, S.1    Blume, W.T.2    Girvin, J.P.3    Eliasziw, M.4
  • 12
    • 0032884447 scopus 로고    scopus 로고
    • Morbidity and infection in combined subdural grid and strip electrode investigation for intractable epilepsy
    • Wiggins GC, Elisevich K, Smith BJ: Morbidity and infection in combined subdural grid and strip electrode investigation for intractable epilepsy. Epilepsy Res 37:73-80, 1999
    • (1999) Epilepsy Res , vol.37 , pp. 73-80
    • Wiggins, G.C.1    Elisevich, K.2    Smith, B.J.3
  • 13
    • 58849156121 scopus 로고    scopus 로고
    • Risk factors for complications during intracranial electrode recording in presurgical evaluation of drug resistant partial epilepsy
    • Wong CH, Birkett J, Byth K, Dexter M, Somerville E, Gill D, et al: Risk factors for complications during intracranial electrode recording in presurgical evaluation of drug resistant partial epilepsy. Acta Neurochir (Wien) 151:37-50, 2009
    • (2009) Acta Neurochir (Wien) , vol.151 , pp. 37-50
    • Wong, C.H.1    Birkett, J.2    Byth, K.3    Dexter, M.4    Somerville, E.5    Gill, D.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.