메뉴 건너뛰기




Volumn 26, Issue 1, 2010, Pages 1-11

A scanned, focused, multiple transducer ultrasonic system for localized hyperthermia treatments

Author keywords

Deep heating; Focused fields; Hyperthermia; Temperature distribution; Ultrasound

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL TISSUE; B SCAN; DOG; HYPERTHERMIC THERAPY; KIDNEY CIRCULATION; NONHUMAN; REVIEW; TEMPERATURE SENSITIVITY; TISSUE PERFUSION; TRANSDUCER; ULTRASOUND SCANNER;

EID: 76149107855     PISSN: 02656736     EISSN: 14645157     Source Type: Journal    
DOI: 10.3109/02656730903492916     Document Type: Review
Times cited : (13)

References (17)
  • 1
    • 0018176359 scopus 로고
    • Ultrasound heating in previously irradiated sites
    • Marmor JB, Hahn GM. Ultrasound heating in previously irradiated sites. Int J Radiat Oncol Biol Phys 1978;4:1029-1032.
    • (1978) Int J Radiat Oncol Biol Phys , vol.4 , pp. 1029-1032
    • Marmor, J.B.1    Hahn, G.M.2
  • 4
    • 0003254607 scopus 로고
    • Physical aspects and clinical studies with ultrasound hyperthermia
    • Storm FC, editor. Boston: Hall Medical Publishers
    • Lele PP. Physical aspects and clinical studies with ultrasound hyperthermia. In: Storm FC, editor. Hyperthermia in Cancer Therapy. Boston: Hall Medical Publishers; 1983. pp 333-367.
    • (1983) Hyperthermia in Cancer Therapy , pp. 333-367
    • Lele, P.P.1
  • 10
    • 0002976643 scopus 로고
    • Ultrasonic measurement techniques and equipment output levels
    • Repacholi MH and Benwell DA, editors. Clifton, NJ: Humana Press
    • Stewart HF. Ultrasonic measurement techniques and equipment output levels. In: Repacholi MH and Benwell DA, editors. Essentials of Medical Ultrasound. Clifton, NJ: Humana Press; 1982. pp 77-116.
    • (1982) Essentials of Medical Ultrasound , pp. 77-116
    • Stewart, H.F.1
  • 11
    • 0020726743 scopus 로고
    • Design of thermistor probes for measurement of ultrasound intensity distributions
    • Martin CJ, Law ANR. Design of thermistor probes for measurement of ultrasound intensity distributions. Ultrasonics 1983;21:85-90.
    • (1983) Ultrasonics , vol.21 , pp. 85-90
    • Martin, C.J.1    Law, A.N.R.2
  • 12
    • 30244463882 scopus 로고
    • Determination of absolute sound levels and acoustic absorption coefficients by thermocouple probes-experiment
    • Fry WJ, Fry RB. Determination of absolute sound levels and acoustic absorption coefficients by thermocouple probes-experiment. J Acoustical Soc Am 1954;26:311-317.
    • (1954) J Acoustical Soc Am , vol.26 , pp. 311-317
    • Fry, W.J.1    Fry, R.B.2
  • 14
    • 0017857596 scopus 로고
    • Thermometry considerations in localized hyperthermia
    • Cetas TC, Connor WG. Thermometry considerations in localized hyperthermia. Med Phys 1978;5:79-91.
    • (1978) Med Phys , vol.5 , pp. 79-91
    • Cetas, T.C.1    Connor, W.G.2
  • 15
    • 0021075884 scopus 로고
    • Errors in temperature measurement by thermocouple probes during ultrasound induced hyperthermia
    • Hynynen K, Martin CJ, Watmough DJ, Mallard JR. Errors in temperature measurement by thermocouple probes during ultrasound induced hyperthermia. Br J Radiol 1983b;56:969-970.
    • (1983) Br J Radiol , vol.56 , pp. 969-970
    • Hynynen, K.1    Martin, C.J.2    Watmough, D.J.3    Mallard, J.R.4
  • 17
    • 0022723024 scopus 로고
    • The effect of scanning speed on temperature and equivalent thermal exposure distributions during ultrasound hyperthermia in vivo
    • Hynynen K, Roemer RB, Moros E, Johnson C, Anhalt D. The effect of scanning speed on temperature and equivalent thermal exposure distributions during ultrasound hyperthermia in vivo. IEEE Trans Microwave Theory Tech 1986;34:552-559.
    • (1986) IEEE Trans Microwave Theory Tech , vol.34 , pp. 552-559
    • Hynynen, K.1    Roemer, R.B.2    Moros, E.3    Johnson, C.4    Anhalt, D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.