메뉴 건너뛰기




Volumn 44, Issue 2, 2010, Pages 101-104

The role of anatomic factors in predicting success of endovascular repair of thoracic aortic aneurysms

Author keywords

Aortic stent graft; Deployment failure; Endoleak; Thoracic aneurysm

Indexed keywords

ANATOMICAL VARIATION; ANEURYSM RUPTURE; ANEURYSM SURGERY; AORTA ANEURYSM; ARTICLE; CALCIFICATION; CLINICAL EVALUATION; CLINICAL FEATURE; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; ENDOLEAK; ENDOVASCULAR SURGERY; FOLLOW UP; HUMAN; ILIAC ARTERY; MAJOR CLINICAL STUDY; MORTALITY; NECK; OPERATING ROOM; OUTCOME ASSESSMENT; PREDICTOR VARIABLE; PREOPERATIVE EVALUATION; THORACIC AORTIC ANEURYSM; THORACIC ENDOVASCULAR ANEURYSM REPAIR; THORAX DISEASE; THREE DIMENSIONAL IMAGING; TREATMENT FAILURE; TREATMENT INDICATION;

EID: 76049094161     PISSN: 15385744     EISSN: None     Source Type: Journal    
DOI: 10.1177/1538574409347392     Document Type: Article
Times cited : (22)

References (12)
  • 1
    • 0036840603 scopus 로고    scopus 로고
    • Natural history of thoracic aortic aneurysms: Indications for surgery, and surgical versus nonsurgical risks
    • Elefteriades JA Natural history of thoracic aortic aneurysms: indications for surgery, and surgical versus nonsurgical risks. Ann Thorac Surg. 2002 ; 74 (5). S1877 - S1880.
    • (2002) Ann Thorac Surg , vol.74 , Issue.5
    • Elefteriades, J.A.1
  • 2
    • 0030942788 scopus 로고    scopus 로고
    • What is the appropriate size criterion for resection of thoracic aortic aneurysms
    • Coady MA, Rizzo JA, Hammond GL, et al. What is the appropriate size criterion for resection of thoracic aortic aneurysms ? J Thorac Cardiovasc Surg. 1997 ; 113 (3). 476-491.
    • (1997) J Thorac Cardiovasc Surg , vol.113 , Issue.3 , pp. 476-491
    • Coady, M.A.1    Rizzo, J.A.2    Hammond, G.L.3
  • 3
    • 0030032140 scopus 로고    scopus 로고
    • The risk of ischemic spinal cord injury in patients undergoing graft replacement for thoracoabdominal aortic aneurysms
    • Grabitz K., Sandmann W., Stühmeier K., et al. The risk of ischemic spinal cord injury in patients undergoing graft replacement for thoracoabdominal aortic aneurysms. J Vasc Surg. 1996 ; 23 (2). 230-240.
    • (1996) J Vasc Surg , vol.23 , Issue.2 , pp. 230-240
    • Grabitz, K.1    Sandmann, W.2    Stühmeier, K.3
  • 4
    • 33947304051 scopus 로고    scopus 로고
    • Delayed spinal cord deficits after thoracoabdominal aortic aneurysm repair
    • Wong DR, Coselli JS, Amerman K., et al. Delayed spinal cord deficits after thoracoabdominal aortic aneurysm repair. Ann Thorac Surg. 2007 ; 83 (4). 1345-1355.
    • (2007) Ann Thorac Surg , vol.83 , Issue.4 , pp. 1345-1355
    • Wong, D.R.1    Coselli, J.S.2    Amerman, K.3
  • 5
    • 0024119126 scopus 로고
    • A case of distant transfemoral endoprosthesis of the thoracic artery using a self-fixing synthetic prosthesis in traumatic aneurysm
    • Volodosg- NL, Karpovich IP, Shekhanin VE, Troian VI, Iakovenko LF [A case of distant transfemoral endoprosthesis of the thoracic artery using a self-fixing synthetic prosthesis in traumatic aneurysm]. Grudn Khir. 1988 ;(6). 84-86.
    • (1988) Grudn Khir , vol.6 , pp. 84-86
    • Volodosg-, N.L.1    Karpovich, I.P.2    Shekhanin, V.E.3    Troian, V.I.4    Iakovenko, L.F.5
  • 6
    • 0028631110 scopus 로고
    • Transluminal placement of endovascular stent-grafts for the treatment of descending thoracic aortic aneurysms
    • Dake MD, Miller DC, Semba CP, Mitchell RS, Walker PJ, Liddell RP Transluminal placement of endovascular stent-grafts for the treatment of descending thoracic aortic aneurysms. N Engl J Med. 1994 ; 331 (26). 1729-1734.
    • (1994) N Engl J Med , vol.331 , Issue.26 , pp. 1729-1734
    • Dake, M.D.1    Miller, D.C.2    Semba, C.P.3    Mitchell, R.S.4    Walker, P.J.5    Liddell, R.P.6
  • 7
    • 49749152060 scopus 로고    scopus 로고
    • Pivotal results of the Medtronic Vascular Talent Thoracic Stent Graft System: The VALOR trial
    • Fairman RM, Criado F., Farber M., et al. Pivotal results of the Medtronic Vascular Talent Thoracic Stent Graft System: the VALOR trial. J Vasc Surg. 2008 ; 48 (3). 546-544.
    • (2008) J Vasc Surg , vol.48 , Issue.3 , pp. 546-544
    • Fairman, R.M.1    Criado, F.2    Farber, M.3
  • 8
    • 10744231885 scopus 로고    scopus 로고
    • Challenges of endovascular tube graft repair of thoracic aortic aneurysm: Midterm follow-up and lessons learned
    • Ellozy SH, Carroccio A., Minor M., et al. Challenges of endovascular tube graft repair of thoracic aortic aneurysm: midterm follow-up and lessons learned. J Vasc Surg. 2003 ; 38 (4). 676-683.
    • (2003) J Vasc Surg , vol.38 , Issue.4 , pp. 676-683
    • Ellozy, S.H.1    Carroccio, A.2    Minor, M.3
  • 9
    • 19044374862 scopus 로고    scopus 로고
    • Identifying and grading factors that modify the outcome of endovascular aortic aneurysm repair
    • Chaikof EL, Fillinger MF, Matsumura JS, et al. Identifying and grading factors that modify the outcome of endovascular aortic aneurysm repair. J Vasc Surg. 2002 ; 35 (5). 1061-1066.
    • (2002) J Vasc Surg , vol.35 , Issue.5 , pp. 1061-1066
    • Chaikof, E.L.1    Fillinger, M.F.2    Matsumura, J.S.3
  • 10
    • 19044393090 scopus 로고    scopus 로고
    • Ad Hoc Committee for Standardized Reporting Practices in Vascular Surgery of the Society for Vascular Surgery/American Association for Vascular Surgery. Reporting standards for endovascular aortic aneurysm repair
    • Chaikof EL, Blankensteijn JD, Harris PL, et al. Ad Hoc Committee for Standardized Reporting Practices in Vascular Surgery of The Society for Vascular Surgery/American Association for Vascular Surgery. Reporting standards for endovascular aortic aneurysm repair. J Vasc Surg. 2002 ; 35 (5). 1048-1060.
    • (2002) J Vasc Surg , vol.35 , Issue.5 , pp. 1048-1060
    • Chaikof, E.L.1    Blankensteijn, J.D.2    Harris, P.L.3
  • 11
    • 49149103884 scopus 로고    scopus 로고
    • Staged repair of thoracic and thoracoabdominal aortic aneurysms using the elephant trunk technique: A consecutive series of 215 first stage and 120 complete repairs
    • Etz CD, Plestis KA, Kari FA, et al. Staged repair of thoracic and thoracoabdominal aortic aneurysms using the elephant trunk technique: a consecutive series of 215 first stage and 120 complete repairs. Eur J CardioThorac Surg. 2008 ; 34 (3). 605-615.
    • (2008) Eur J CardioThorac Surg , vol.34 , Issue.3 , pp. 605-615
    • Etz, C.D.1    Plestis, K.A.2    Kari, F.A.3
  • 12
    • 33846657728 scopus 로고    scopus 로고
    • Endovascular abdominal aortic aneurysm sizing and case planning using the TeraRecon Aquarius workstation
    • Lee WA Endovascular abdominal aortic aneurysm sizing and case planning using the TeraRecon Aquarius workstation. Vasc Endovas Surg. 2007 ; 41 (1). 61-67.
    • (2007) Vasc Endovas Surg , vol.41 , Issue.1 , pp. 61-67
    • Lee, W.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.