메뉴 건너뛰기




Volumn 9, Issue 1, 2010, Pages 21-27

Initial investigation of preclinical integrated SPECT and MR imaging

Author keywords

MRI; MRSPECT; Multimodality imaging; SPECT

Indexed keywords

CADMIUM; TECHNETIUM 99M; TELLURIUM; ZINC;

EID: 76049085536     PISSN: 15330346     EISSN: None     Source Type: Journal    
DOI: 10.1177/153303461000900103     Document Type: Article
Times cited : (19)

References (12)
  • 1
    • 33748057162 scopus 로고    scopus 로고
    • Rationale for the Combination of Nuclear Medicine with Magnetic Resonance for Pre-clinical Imaging
    • Wagenaar, D. J., Kapusta, M., Li, J., Patt, B. E. Rationale for the Combination of Nuclear Medicine with Magnetic Resonance for Pre-clinical Imaging. Technol Cancer Res Treat 5, 343-350 (2006).
    • (2006) Technol Cancer Res Treat , vol.5 , pp. 343-350
    • Wagenaar, D.J.1    Kapusta, M.2    Li, J.3    Patt, B.E.4
  • 3
    • 37649002370 scopus 로고    scopus 로고
    • Goetz, C., Breton, E., Choquet, P., Israel-Jost, V., Constantinesco, A. MRI System for Small-Animal Imaging. J Nucl Med 49, 88-93 (2008).
    • Goetz, C., Breton, E., Choquet, P., Israel-Jost, V., Constantinesco, A. MRI System for Small-Animal Imaging. J Nucl Med 49, 88-93 (2008).
  • 4
    • 48149114140 scopus 로고    scopus 로고
    • Design Study of an MRI Compatible Ultra-high Resolution SPECT for In Vivo Mice Brain Imaging
    • Meng, L. J., Tan, J. W., Geng, F. Design Study of an MRI Compatible Ultra-high Resolution SPECT for In Vivo Mice Brain Imaging. IEEE 2007 Nuc Sci Sym Conference Record, 2956-2960 (2007).
    • (2007) IEEE 2007 Nuc Sci Sym Conference Record , pp. 2956-2960
    • Meng, L.J.1    Tan, J.W.2    Geng, F.3
  • 8
    • 0028783994 scopus 로고
    • In-vivo Automated Shimming Method Taking Into Account Shim Current Constraints
    • Wen, H., Jaffer, F. A. An In-vivo Automated Shimming Method Taking Into Account Shim Current Constraints. Magn Reson Med 34, 898-904 (1995).
    • (1995) Magn Reson Med , vol.34 , pp. 898-904
    • Wen, H.1    Jaffer, F.A.A.2
  • 9
    • 33748077129 scopus 로고    scopus 로고
    • Resolution Improvement in Positron Emission Tomography Using Anatomical Magnetic Resonance Imaging
    • Chu, Y., Su, M. Y., Mandelkern, M., Nalcioglu, O. Resolution Improvement in Positron Emission Tomography Using Anatomical Magnetic Resonance Imaging. Technol Cancer Res Treat 5, 311-317 (2006).
    • (2006) Technol Cancer Res Treat , vol.5 , pp. 311-317
    • Chu, Y.1    Su, M.Y.2    Mandelkern, M.3    Nalcioglu, O.4
  • 10
    • 0017452940 scopus 로고
    • A Method for Attenuation Correction in Radionuclide Computed Tomography
    • Chang, L. A Method for Attenuation Correction in Radionuclide Computed Tomography. IEEE Trans Nucl Sci 25, 638-653 (1978).
    • (1978) IEEE Trans Nucl Sci , vol.25 , pp. 638-653
    • Chang, L.1
  • 11
    • 65449150935 scopus 로고    scopus 로고
    • A Variable Torque Motor Compatible With Magnetic Resonance Imaging
    • Roeck, W. W., Ha, S-H., Farmaka, S., Nalcioglu, O. A Variable Torque Motor Compatible With Magnetic Resonance Imaging. Rev Sci Instrum 80, 046108 (2009).
    • (2009) Rev Sci Instrum , vol.80 , pp. 046108
    • Roeck, W.W.1    Ha, S.-H.2    Farmaka, S.3    Nalcioglu, O.4
  • 12
    • 85036787441 scopus 로고    scopus 로고
    • Development of a New RF Coil and γ-ray Radiation Shielding Assembly for a SPECT/MRI System
    • submitted
    • Ha, S., Hamamura, M. J., Roeck, W. W., Muftuler, L. T., Nalcioglu, O. Development of a New RF Coil and γ-ray Radiation Shielding Assembly for a SPECT/MRI System. Phys Med Biol (submitted).
    • Phys Med Biol
    • Ha, S.1    Hamamura, M.J.2    Roeck, W.W.3    Muftuler, L.T.4    Nalcioglu, O.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.