메뉴 건너뛰기




Volumn 45, Issue 6, 2010, Pages 1441-1447

A CFD-based test method for control of indoor environment and space ventilation

Author keywords

Computational fluid dynamics; Online control test; System simulation; Temperature stratification; Ventilation control

Indexed keywords

AIR MODELS; AIR TEMPERATURE; AIRCONDITIONING SYSTEMS; CFD MODELS; CFD SIMULATIONS; CONTROL AND OPTIMIZATION; DAMPER MODEL; INDOOR ENVIRONMENT; NEW APPLICATIONS; NONUNIFORM; ON-LINE CONTROLS; OPTIMAL CONTROL STRATEGY; PERFECT MIXING MODEL; PID CONTROLLERS; SPACE-VENTILATION; SUPERVISORY CONTROL; SYSTEM CONTROL; SYSTEM DYNAMICS; SYSTEM SIMULATION; TEMPERATURE OFFSET; TEST METHOD; USER DEFINED FUNCTIONS; VENTILATED ROOM; VENTILATION CONTROL; VIRTUAL SENSOR; VIRTUAL TESTS;

EID: 75949119143     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.buildenv.2009.12.007     Document Type: Article
Times cited : (61)

References (27)
  • 1
    • 0032643161 scopus 로고    scopus 로고
    • Dynamic simulation evaluation of building VAV air-conditioning system and of EMCS on-line control strategies
    • Wang S.W. Dynamic simulation evaluation of building VAV air-conditioning system and of EMCS on-line control strategies. Building and Environment 34 (1999) 681-705
    • (1999) Building and Environment , vol.34 , pp. 681-705
    • Wang, S.W.1
  • 2
    • 0038006785 scopus 로고    scopus 로고
    • Adaptive comfort temperature model of air-conditioned building in Hong Kong
    • Kwok W.H.M., and Wai T.D.C. Adaptive comfort temperature model of air-conditioned building in Hong Kong. Building and Environment 38 (2003) 837-852
    • (2003) Building and Environment , vol.38 , pp. 837-852
    • Kwok, W.H.M.1    Wai, T.D.C.2
  • 4
    • 0034106064 scopus 로고    scopus 로고
    • Model-based optimal control of VAV air-conditioning system using genetic algorithm
    • Wang S.W., and Jin X.Q. Model-based optimal control of VAV air-conditioning system using genetic algorithm. Building and Environment 35 (2000) 471-487
    • (2000) Building and Environment , vol.35 , pp. 471-487
    • Wang, S.W.1    Jin, X.Q.2
  • 5
    • 33745494846 scopus 로고    scopus 로고
    • Multiple-zone ventilation and temperature control of a single-duct VAV system using model predictive strategy
    • Yuan S., and Perez R. Multiple-zone ventilation and temperature control of a single-duct VAV system using model predictive strategy. Energy and Buildings 38 (2006) 1248-1261
    • (2006) Energy and Buildings , vol.38 , pp. 1248-1261
    • Yuan, S.1    Perez, R.2
  • 6
    • 0942291282 scopus 로고    scopus 로고
    • Development of a dual-mode demand control ventilation strategy for indoor air quality control and energy saving
    • Chao C.Y.H., and Hu J.S. Development of a dual-mode demand control ventilation strategy for indoor air quality control and energy saving. Building and Environment 39 (2004) 385-397
    • (2004) Building and Environment , vol.39 , pp. 385-397
    • Chao, C.Y.H.1    Hu, J.S.2
  • 7
    • 33846948943 scopus 로고    scopus 로고
    • Optimization of energy consumption in buildings with hydronic heating systems considering thermal comfort by use of computer-based tools
    • Djuric N., Novakovic V., Holst J., and Mitrovic Z. Optimization of energy consumption in buildings with hydronic heating systems considering thermal comfort by use of computer-based tools. Energy and Buildings 39 (2007) 471-477
    • (2007) Energy and Buildings , vol.39 , pp. 471-477
    • Djuric, N.1    Novakovic, V.2    Holst, J.3    Mitrovic, Z.4
  • 8
    • 37449010409 scopus 로고    scopus 로고
    • Numerical investigation on thermal performance and correlations of double skin façade with buoyancy-driven airflow
    • Pappas A., and Zhai Z. Numerical investigation on thermal performance and correlations of double skin façade with buoyancy-driven airflow. Energy and Buildings 40 (2008) 466-475
    • (2008) Energy and Buildings , vol.40 , pp. 466-475
    • Pappas, A.1    Zhai, Z.2
  • 9
    • 10444274228 scopus 로고    scopus 로고
    • Performance of coupled building energy and CFD simulations
    • Zhai Z.J., and Chen Q.Y. Performance of coupled building energy and CFD simulations. Energy and Buildings 37 (2005) 333-344
    • (2005) Energy and Buildings , vol.37 , pp. 333-344
    • Zhai, Z.J.1    Chen, Q.Y.2
  • 11
    • 0032141977 scopus 로고    scopus 로고
    • Using numerical simulation to predict ventilation efficiency in a model room
    • Chung I.P., and Dunn-Rankin D. Using numerical simulation to predict ventilation efficiency in a model room. Energy and Buildings 28 (1998) 43-50
    • (1998) Energy and Buildings , vol.28 , pp. 43-50
    • Chung, I.P.1    Dunn-Rankin, D.2
  • 12
    • 0034174176 scopus 로고    scopus 로고
    • Airflow malt distribution and the performance of a packaged air-conditioning unit evaporator
    • Aganda A.A., Coney J.E.R., and Sheppard C.G.W. Airflow malt distribution and the performance of a packaged air-conditioning unit evaporator. Applied Thermal Engineering 20 (2000) 515-528
    • (2000) Applied Thermal Engineering , vol.20 , pp. 515-528
    • Aganda, A.A.1    Coney, J.E.R.2    Sheppard, C.G.W.3
  • 13
    • 0033742745 scopus 로고    scopus 로고
    • Numerical simulation of two-dimensional room air flow with and without buoyancy
    • Sinha S.L., Aroraand R.C., and Roy S. Numerical simulation of two-dimensional room air flow with and without buoyancy. Energy and Buildings 32 (2000) 121-129
    • (2000) Energy and Buildings , vol.32 , pp. 121-129
    • Sinha, S.L.1    Aroraand, R.C.2    Roy, S.3
  • 14
    • 0029390545 scopus 로고
    • Comparison of different k-ε models for indoor air flow computations
    • Chen Q. Comparison of different k-ε models for indoor air flow computations. Numerical Heat Transfer 28 (1995) 353-369
    • (1995) Numerical Heat Transfer , vol.28 , pp. 353-369
    • Chen, Q.1
  • 15
    • 0035400788 scopus 로고    scopus 로고
    • A two-layer turbulence model for simulating indoor airflow - Part I: model development
    • Xu W., and Chen Q. A two-layer turbulence model for simulating indoor airflow - Part I: model development. Energy and Buildings 33 (2001) 613-625
    • (2001) Energy and Buildings , vol.33 , pp. 613-625
    • Xu, W.1    Chen, Q.2
  • 16
    • 0035400562 scopus 로고    scopus 로고
    • A two-layer turbulence model for simulating indoor airflow - Part II: applications
    • Xu W., and Chen Q. A two-layer turbulence model for simulating indoor airflow - Part II: applications. Energy and Buildings 33 (2001) 627-639
    • (2001) Energy and Buildings , vol.33 , pp. 627-639
    • Xu, W.1    Chen, Q.2
  • 17
    • 75949100161 scopus 로고
    • Airflow and temperature distribution within an open-plan building space using a displacement ventilation system
    • Alamdari F, Bennett KM, Rose PM. Airflow and temperature distribution within an open-plan building space using a displacement ventilation system. In: Proceeding of room vent; 1994.
    • (1994) Proceeding of room vent
    • Alamdari, F.1    Bennett, K.M.2    Rose, P.M.3
  • 18
    • 0034745038 scopus 로고    scopus 로고
    • CFD analysis and energy simulation of a gymnasium
    • Lam J.C., and Chan A.L.S. CFD analysis and energy simulation of a gymnasium. Building and Environment 36 (2001) 351-358
    • (2001) Building and Environment , vol.36 , pp. 351-358
    • Lam, J.C.1    Chan, A.L.S.2
  • 19
    • 0033880292 scopus 로고    scopus 로고
    • Mathematical modeling of environmental conditions inside historical buildings - the case of the archaeological museum of Athens
    • Papakonstantinou K.A., Kiranoudis C.T., and Markatos N.C. Mathematical modeling of environmental conditions inside historical buildings - the case of the archaeological museum of Athens. Energy and Buildings 31 (2000) 211-220
    • (2000) Energy and Buildings , vol.31 , pp. 211-220
    • Papakonstantinou, K.A.1    Kiranoudis, C.T.2    Markatos, N.C.3
  • 20
    • 33749328141 scopus 로고    scopus 로고
    • Two-step optimal design method using genetic algorithms and CFD-coupled simulation for indoor thermal environments
    • Kim T., Song D., Kato S., and Murakami S. Two-step optimal design method using genetic algorithms and CFD-coupled simulation for indoor thermal environments. Applied Thermal Engineering 27 (2007) 3-11
    • (2007) Applied Thermal Engineering , vol.27 , pp. 3-11
    • Kim, T.1    Song, D.2    Kato, S.3    Murakami, S.4
  • 23
    • 0032643161 scopus 로고    scopus 로고
    • Dynamic simulation of building VAV air-conditioning system and evaluation of EMCS on-line control
    • Wang S.W. Dynamic simulation of building VAV air-conditioning system and evaluation of EMCS on-line control. Build Environment 34 (1999) 681-705
    • (1999) Build Environment , vol.34 , pp. 681-705
    • Wang, S.W.1
  • 24
    • 0037409023 scopus 로고    scopus 로고
    • Measurement and prediction of indoor air flow in a model room
    • Posner J.D., Buchanan C.R., and Dunn-Rankin D. Measurement and prediction of indoor air flow in a model room. Energy and Building 35 (2003) 515-526
    • (2003) Energy and Building , vol.35 , pp. 515-526
    • Posner, J.D.1    Buchanan, C.R.2    Dunn-Rankin, D.3
  • 26
    • 0032647807 scopus 로고    scopus 로고
    • COMIS - an international multizone air-flow and contaminant transport model
    • Feustel H.E. COMIS - an international multizone air-flow and contaminant transport model. Energy and Buildings 30 (1999) 3-18
    • (1999) Energy and Buildings , vol.30 , pp. 3-18
    • Feustel, H.E.1
  • 27
    • 0037333676 scopus 로고    scopus 로고
    • Simulating air flow and temperature distribution inside buildings using a modified version of COMIS with sub-zonal divisions
    • Ren Z., and Stewart J. Simulating air flow and temperature distribution inside buildings using a modified version of COMIS with sub-zonal divisions. Energy and Buildings 35 (2003) 257-271
    • (2003) Energy and Buildings , vol.35 , pp. 257-271
    • Ren, Z.1    Stewart, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.