-
1
-
-
33750970326
-
Pacemakers and implantable cardioverter-defibrillators in pediatric patients
-
Silka MJ, Bar-Cohen Y. Pacemakers and implantable cardioverter- defibrillators in pediatric patients. Heart Rhythm 2006 3: 1360 1366.
-
(2006)
Heart Rhythm
, vol.3
, pp. 1360-1366
-
-
Silka, M.J.1
Bar-Cohen, Y.2
-
2
-
-
34248579318
-
Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of>10 years
-
Kleemann T, Becker T, Doenges K, Vater M, Senges J, Schneider S, Saggau W, et al. Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of>10 years. Circulation 2007 115: 2474 2480.
-
(2007)
Circulation
, vol.115
, pp. 2474-2480
-
-
Kleemann, T.1
Becker, T.2
Doenges, K.3
Vater, M.4
Senges, J.5
Schneider, S.6
Saggau, W.7
-
3
-
-
0037281531
-
Transvenous defibrillation leads: High incidence of failure during long-term follow-up
-
Dorwarth U, Frey B, Dugas M, Matis T, Fiek M, Schmoeckel M, Remp T, et al. Transvenous defibrillation leads: High incidence of failure during long-term follow-up. J Cardiovasc Electrophysiol 2003 14: 38 43.
-
(2003)
J Cardiovasc Electrophysiol
, vol.14
, pp. 38-43
-
-
Dorwarth, U.1
Frey, B.2
Dugas, M.3
Matis, T.4
Fiek, M.5
Schmoeckel, M.6
Remp, T.7
-
4
-
-
0036630486
-
Implantable cardioverter defibrillator therapy for life-threatening arrhythmias in young patients
-
Stefanelli CB, Bradley DJ, Leroy S, Dick M, 2nd., Serwer GA, Fischbach PS. Implantable cardioverter defibrillator therapy for life-threatening arrhythmias in young patients. J Intervent Card Electrophysiol 2002 6: 235 244.
-
(2002)
J Intervent Card Electrophysiol
, vol.6
, pp. 235-244
-
-
Stefanelli, C.B.1
Bradley, D.J.2
Leroy, S.3
Dick II, M.4
Serwer, G.A.5
Fischbach, P.S.6
-
5
-
-
0033556152
-
Comparison of frequency of complications of implantable cardioverter-defibrillators in children versus adults
-
Link MS, Hill SL, Cliff DL, Swygman CA, Foote CB, Homoud MK, Wang PJ, et al. Comparison of frequency of complications of implantable cardioverter- defibrillators in children versus adults. Amer J Cardiol 1999 83: 263 266.
-
(1999)
Amer J Cardiol
, vol.83
, pp. 263-266
-
-
Link, M.S.1
Hill, S.L.2
Cliff, D.L.3
Swygman, C.A.4
Foote, C.B.5
Homoud, M.K.6
Wang, P.J.7
-
6
-
-
0037623303
-
Implantable cardioverter defibrillator lead complications and laser extraction in children and young adults with congenital heart disease: Implications for implantation and management
-
Cooper JM, Stephenson EA, Berul CI, Walsh EP, Epstein LM. Implantable cardioverter defibrillator lead complications and laser extraction in children and young adults with congenital heart disease: Implications for implantation and management. J Cardiovasc Electrophysiol 2003 14: 344 349.
-
(2003)
J Cardiovasc Electrophysiol
, vol.14
, pp. 344-349
-
-
Cooper, J.M.1
Stephenson, E.A.2
Berul, C.I.3
Walsh, E.P.4
Epstein, L.M.5
-
7
-
-
0742324990
-
Implications of implantable cardioverter defibrillator therapy in congenital heart disease and pediatrics
-
[see comment]
-
Alexander ME, Cecchin F, Walsh EP, Triedman JK, Bevilacqua LM, Berul CI. Implications of implantable cardioverter defibrillator therapy in congenital heart disease and pediatrics [see comment]. J Cardiovasc Electrophysiol 2004 15: 72 76.
-
(2004)
J Cardiovasc Electrophysiol
, vol.15
, pp. 72-76
-
-
Alexander, M.E.1
Cecchin, F.2
Walsh, E.P.3
Triedman, J.K.4
Bevilacqua, L.M.5
Berul, C.I.6
-
8
-
-
43049118272
-
Results of a multicenter retrospective implantable cardioverter- defibrillator registry of pediatric and congenital heart disease patients
-
Berul CI, Van Hare GF, Kertesz NJ, Dubin AM, Cecchin F, Collins KK, Cannon BC, et al. Results of a multicenter retrospective implantable cardioverter-defibrillator registry of pediatric and congenital heart disease patients. J Amer Coll Cardiol 2008 51: 1685 1691.
-
(2008)
J Amer Coll Cardiol
, vol.51
, pp. 1685-1691
-
-
Berul, C.I.1
Van Hare, G.F.2
Kertesz, N.J.3
Dubin, A.M.4
Cecchin, F.5
Collins, K.K.6
Cannon, B.C.7
-
9
-
-
34250749315
-
Early failure of a small-diameter high-voltage implantable cardioverter-defibrillator lead
-
Hauser RG, Kallinen LM, Almquist AK, Gornick CC, Katsiyiannis WT. Early failure of a small-diameter high-voltage implantable cardioverter-defibrillator lead. Heart Rhythm 2007 4: 892 896.
-
(2007)
Heart Rhythm
, vol.4
, pp. 892-896
-
-
Hauser, R.G.1
Kallinen, L.M.2
Almquist, A.K.3
Gornick, C.C.4
Katsiyiannis, W.T.5
-
10
-
-
0035169738
-
Lead- and device-related complications in the antiarrhythmics versus implantable defibrillators trial
-
DOI 10.1067/mhj.2001.111261
-
Kron J, Herre J, Renfroe EG, Rizo-Patron C, Raitt M, Halperin B, Gold M, et al. Lead-and device-related complications in the antiarrhythmics versus implantable defibrillators trial. Amer Heart J 2001 141: 92 98. (Pubitemid 32061317)
-
(2001)
American Heart Journal
, vol.141
, Issue.1
, pp. 92-98
-
-
Kron, J.1
Herre, J.2
Renfroe, E.G.3
Rizo-Patron, C.4
Raitt, M.5
Halperin, B.6
Gold, M.7
Goldner, B.8
Wathen, M.9
Wilkoff, B.10
Olarte, A.11
Yao, Q.12
-
11
-
-
0025823921
-
Transvenous pacemakers in children: Relation of lead length to anticipated growth
-
Gheissari A, Hordof AJ, Spotnitz HM. Transvenous pacemakers in children: Relation of lead length to anticipated growth. Ann Thorac Surg 1991 52: 118 121.
-
(1991)
Ann Thorac Surg
, vol.52
, pp. 118-121
-
-
Gheissari, A.1
Hordof, A.J.2
Spotnitz, H.M.3
-
12
-
-
0034494712
-
Inferior vena cava loop of the implantable cardioverter defibrillator endocardial lead: A possible solution of the growth problem in pediatric implantation
-
[see comment]
-
Gasparini M, Mantica M, Galimberti P, Coltorti F, Ceriotti C, Priori SG. Inferior vena cava loop of the implantable cardioverter defibrillator endocardial lead: A possible solution of the growth problem in pediatric implantation [see comment]. Pacing Clin Electrophysiol 2000 23: 2108 2112.
-
(2000)
Pacing Clin Electrophysiol
, vol.23
, pp. 2108-2112
-
-
Gasparini, M.1
Mantica, M.2
Galimberti, P.3
Coltorti, F.4
Ceriotti, C.5
Priori, S.G.6
|