메뉴 건너뛰기




Volumn 37, Issue 2, 2010, Pages 694-703

Filtered region of interest cone-beam rotational angiography

Author keywords

Computed tomography; Dose reduction in CT; Region of interest imaging

Indexed keywords

ANGIOGRAPHY; IMAGE QUALITY; IMAGE RECONSTRUCTION; IMAGE SEGMENTATION; QUALITY CONTROL; X RAY DETECTORS; X RAYS;

EID: 75749155510     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3284540     Document Type: Article
Times cited : (21)

References (31)
  • 1
    • 0034076908 scopus 로고    scopus 로고
    • Three-dimensional reconstructed rotational digital subtraction angiography in planning treatment of intracranial aneurysms
    • ZZZZZZ 0938-7994,. 10.1007/s003300050961
    • U. Missler, M. Wiesmann, T. Mayer, and H. Brackmann, " Three-dimensional reconstructed rotational digital subtraction angiography in planning treatment of intracranial aneurysms.," Eur. Radiol. ZZZZZZ 0938-7994 10, 564-568 (2000). 10.1007/s003300050961
    • (2000) Eur. Radiol. , vol.10 , pp. 564-568
    • Missler, U.1    Wiesmann, M.2    Mayer, T.3    Brackmann, H.4
  • 2
    • 0036677920 scopus 로고    scopus 로고
    • Comparison of three-dimensional rotational angiography with digital subtraction angiography in the assessment of ruptured cerebral aneurysms
    • ZZZZZZ 0195-6108.
    • A. Hochmuth, U. Spetzger, and M. Schumacher, " Comparison of three-dimensional rotational angiography with digital subtraction angiography in the assessment of ruptured cerebral aneurysms.," AJNR Am. J. Neuroradiol. ZZZZZZ 0195-6108 25, 1199-1205 (2002).
    • (2002) AJNR Am. J. Neuroradiol. , vol.25 , pp. 1199-1205
    • Hochmuth, A.1    Spetzger, U.2    Schumacher, M.3
  • 3
    • 16644376545 scopus 로고    scopus 로고
    • Simultaneous bilaterial internal carotid artery 3D rotational angiography
    • ZZZZZZ 0195-6108.
    • J. K. Song, Y. Niimi, J. L. Brisman, and A. Berenstein, " Simultaneous bilaterial internal carotid artery 3D rotational angiography.," AJNR Am. J. Neuroradiol. ZZZZZZ 0195-6108 27, 1787-1789 (2004).
    • (2004) AJNR Am. J. Neuroradiol. , vol.27 , pp. 1787-1789
    • Song, J.K.1    Niimi, Y.2    Brisman, J.L.3    Berenstein, A.4
  • 4
    • 33845328849 scopus 로고    scopus 로고
    • Dose and image quality for a cone-beam C-arm CT system
    • DOI 10.1118/1.2370508, 013612MPH
    • R. Fahrig, R. Dixon, T. Payne, R. L. Morin, A. Ganguly, and N. Strobel, " Dose and image quality for cone-beam C-arm CT system.," Med. Phys. MPHYA6 0094-2405 33 (12), 4541-4550 (2006). 10.1118/1.2370508 (Pubitemid 44868090)
    • (2006) Medical Physics , vol.33 , Issue.12 , pp. 4541-4550
    • Fahrig, R.1    Dixon, R.2    Payne, T.3    Morin, R.L.4    Ganguly, A.5    Strobel, N.6
  • 5
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography - An increasing source of radiation exposure
    • DOI 10.1056/NEJMra072149
    • D. J. Brenner and E. J. Hall, " Computed tomography-An increasing source of radiation exposure.," N. Engl. J. Med. NEJMAG 0028-4793 357, 2277-2284 (2007). 10.1056/NEJMra072149 (Pubitemid 350190758)
    • (2007) New England Journal of Medicine , vol.357 , Issue.22 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 6
    • 33645562681 scopus 로고    scopus 로고
    • CT dose reduction and dose management tools: Overview of available options
    • ZZZZZZ 0271-5333,. 10.1148/rg.262055138
    • C. H. McCollough, M. R. Bruesewitz, and J. M. Kofler, " CT dose reduction and dose management tools: Overview of available options.," Radiographics ZZZZZZ 0271-5333 26, 503-512 (2006). 10.1148/rg.262055138
    • (2006) Radiographics , vol.26 , pp. 503-512
    • McCollough, C.H.1    Bruesewitz, M.R.2    Kofler, J.M.3
  • 7
    • 0021386140 scopus 로고
    • A reconstruction algorithm from truncated projections
    • 10.1109/TMI.1984.4307648
    • K. Ogawa, M. Nakajima, and Y. Shin'Ichi, " A reconstruction algorithm from truncated projections.," IEEE. Trans. Med. Imaging 3 (1), 34-40 (1984). 10.1109/TMI.1984.4307648
    • (1984) IEEE. Trans. Med. Imaging , vol.3 , Issue.1 , pp. 34-40
    • Ogawa, K.1    Nakajima, M.2    Shin'Ichi, Y.3
  • 9
    • 0033342434 scopus 로고    scopus 로고
    • Cone beam local tomography
    • ZZZZZZ 1110-757X ().
    • A. Katsevich, " Cone beam local tomography.," J. Appl. Math. ZZZZZZ 1110-757X 59 (6), 2224-2246 (1999).
    • (1999) J. Appl. Math. , vol.59 , Issue.6 , pp. 2224-2246
    • Katsevich, A.1
  • 10
    • 0033954645 scopus 로고    scopus 로고
    • Efficient correction for CT image artifacts caused by objects extending outside the scan field of view
    • DOI 10.1118/1.598855
    • B. Ohnesorge, T. Flohr, K. Schwarz, J. P. Heiken, and K. T. Bae, " Efficient correction for CT image artifacts caused by objects extending outside the scan field of view.," Med. Phys. MPHYA6 0094-2405 27 (1), 39-46 (2000). 10.1118/1.598855 (Pubitemid 30051909)
    • (2000) Medical Physics , vol.27 , Issue.1 , pp. 39-46
    • Ohnesorge, B.1    Flohr, T.2    Schwarz, K.3    Heiken, J.P.4    Bae, K.T.5
  • 11
    • 5644235370 scopus 로고    scopus 로고
    • A new algorithm for 2D region of interest tomography
    • PSISDG 0277-786X,. 10.1117/12.536685
    • G. Van Gompel, G. Tisson, D. Van Dyck, and J. Sijbers, " A new algorithm for 2D region of interest tomography.," Proc. SPIE PSISDG 0277-786X 5370, 2105-2113 (2004). 10.1117/12.536685
    • (2004) Proc. SPIE , vol.5370 , pp. 2105-2113
    • Van Gompel, G.1    Tisson, G.2    Van Dyck, D.3    Sijbers, J.4
  • 12
    • 36649008065 scopus 로고    scopus 로고
    • Region-of-interest image reconstruction in circular cone-beam microCT
    • DOI 10.1118/1.2804924
    • S. Cho, J. Bian, C. A. Pelizzari, C. -T. Chen, T. -C. He, and X. Pan, " Region-of-interest reconstruction in circular cone-beam microCT'.," Med. Phys. MPHYA6 0094-2405 34 (12), 4923-4933 (2007). 10.1118/1.2804924 (Pubitemid 350197727)
    • (2007) Medical Physics , vol.34 , Issue.12 , pp. 4923-4933
    • Cho, S.1    Bian, J.2    Pelizzari, C.A.3    Chen, C.-T.4    He, T.-C.5    Pan, X.6
  • 13
    • 67649892573 scopus 로고    scopus 로고
    • Compressed sensing based interior tomography
    • PHMBA7 0031-9155,. 10.1088/0031-9155/54/9/014
    • H. Yu and G. Wang, " Compressed sensing based interior tomography.," Phys. Med. Biol. PHMBA7 0031-9155 54, 2791-2805 (2009). 10.1088/0031-9155/54/9/014
    • (2009) Phys. Med. Biol. , vol.54 , pp. 2791-2805
    • Yu, H.1    Wang, G.2
  • 14
    • 42449133835 scopus 로고    scopus 로고
    • Tiny a priori knowledge solves the interior problem in computed tomography
    • DOI 10.1088/0031-9155/53/9/001, PII S0031915508723194
    • H. Kudo, M. Courdurier, F. Noo, and M. Defrise, " Tiny a priori knowledge solves the interior problem in computed tomography.," Phys. Med. Biol. PHMBA7 0031-9155 53, 2207-2231 (2008). 10.1088/0031-9155/53/9/001 (Pubitemid 351570907)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.9 , pp. 2207-2231
    • Kudo, H.1    Courdurier, M.2    Noo, F.3    Defrise, M.4
  • 17
    • 0026806132 scopus 로고
    • Region of interest fluoroscopy
    • MPHYA6 0094-2405 (),. 10.1118/1.596792
    • S. Rudin and D. R. Bednarek, " Region of interest fluoroscopy.," Med. Phys. MPHYA6 0094-2405 19 (5), 1183-1192 (1992). 10.1118/1.596792
    • (1992) Med. Phys. , vol.19 , Issue.5 , pp. 1183-1192
    • Rudin, S.1    Bednarek, D.R.2
  • 18
    • 0030014209 scopus 로고    scopus 로고
    • Application of region-of-interest imaging techniques to neurointerventional radiology
    • S. Rudin, L. R. Gutterman, W. E. Granger, D. R. Bednarek, and L. N. Hopkins, " Applications of region-of-interest imaging techniques in neurointerventional radiology.," Radiology RADLAX 0033-8419 199, 870-873 (1996). (Pubitemid 26157499)
    • (1996) Radiology , vol.199 , Issue.3 , pp. 870-873
    • Rudin, S.1    Guterman, L.R.2    Granger, W.E.3    Bednarek, D.R.4    Hopkins, L.N.5
  • 19
    • 0032767843 scopus 로고    scopus 로고
    • Real-time equalization of region-of-interest fluoroscopic images using binary masks
    • DOI 10.1118/1.598631
    • S. Rudin, D. R. Bednarek, and C. H. J. Yang, " Real-time equalization of region-of-interest fluoroscopic images using binary masks.," Med. Phys. MPHYA6 0094-2405 26 (7), 1359-1364 (1999). 10.1118/1.598631 (Pubitemid 29334804)
    • (1999) Medical Physics , vol.26 , Issue.7 , pp. 1359-1364
    • Rudin, S.1    Bednarek, D.R.2    Yang, C.-Y.J.3
  • 21
    • 48449101393 scopus 로고    scopus 로고
    • Feasibility of volume-of-interest (VOI) scanning technique in cone beam breast CT-A preliminary study
    • MPHYA6 0094-2405 (),. 10.1118/1.2948397
    • L. Chen, C. C. Shaw, M. C. Altunbas, C. J. Lai, X. Liu, T. Han, T. Wang, W. T. Yang, and G. J. Whitman, " Feasibility of volume-of-interest (VOI) scanning technique in cone beam breast CT-A preliminary study.," Med. Phys. MPHYA6 0094-2405 35 (8), 3482-3490 (2008). 10.1118/1.2948397
    • (2008) Med. Phys. , vol.35 , Issue.8 , pp. 3482-3490
    • Chen, L.1    Shaw, C.C.2    Altunbas, M.C.3    Lai, C.J.4    Liu, X.5    Han, T.6    Wang, T.7    Yang, W.T.8    Whitman, G.J.9
  • 22
    • 63849324256 scopus 로고    scopus 로고
    • Region-of-interest image reconstruction with intensity weighting in circular cone-beam CT for image-guided radiation therapy
    • MPHYA6 0094-2405 (),. 10.1118/1.3085825
    • S. Cho, E. Pearson, and X. Pelizzari Cam Pan, " Region-of-interest image reconstruction with intensity weighting in circular cone-beam CT for image-guided radiation therapy.," Med. Phys. MPHYA6 0094-2405 36 (4), 1184-1192 (2009). 10.1118/1.3085825
    • (2009) Med. Phys. , vol.36 , Issue.4 , pp. 1184-1192
    • Cho, S.1    Pearson, E.2    Pelizzari Cam Pan, X.3
  • 23
    • 3242756880 scopus 로고    scopus 로고
    • Image reconstruction on PI-lines by use of filtered backprojection in helical cone-beam CT
    • DOI 10.1088/0031-9155/49/12/017, PII S0031915504774345
    • Y. Zou and X. Pan, " Image reconstruction on PI-lines by use of filtered back projection in helical cone-beam CT.," Phys. Med. Biol. PHMBA7 0031-9155 49, 2717-2731 (2004). 10.1088/0031-9155/49/12/017 (Pubitemid 38967955)
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.12 , pp. 2717-2731
    • Zou, Y.1    Pan, X.2
  • 24
    • 0031885354 scopus 로고    scopus 로고
    • Filter material selection for region of interest radiologic imaging
    • DOI 10.1118/1.598191
    • P. Massoumzadeh, S. Rudin, and D. R. Bednarek, " Filter material selection for region of interest radiologic imaging.," Med. Phys. MPHYA6 0094-2405 25 (2), 161-171 (1998). 10.1118/1.598191 (Pubitemid 28099847)
    • (1998) Medical Physics , vol.25 , Issue.2 , pp. 161-171
    • Massoumzadeh, P.1    Rudin, S.2    Bednarek, D.R.3
  • 25
    • 0021445363 scopus 로고
    • Practical cone-beam algorithm
    • JOSAAH 0030-3941,. 10.1364/JOSAA.1.000612
    • L. A. Feldkamp, L. C. Davis, and J. W. Kress, " Practical cone-beam algorithm.," J. Opt. Soc. Am. JOSAAH 0030-3941 1, 612-619 (1984). 10.1364/JOSAA.1.000612
    • (1984) J. Opt. Soc. Am. , vol.1 , pp. 612-619
    • Feldkamp, L.A.1    Davis, L.C.2    Kress, J.W.3
  • 27
    • 33744593145 scopus 로고
    • The measurement of patient dose
    • BJRAAP 0007-1285,. 10.1259/0007-1285-38-454-766
    • G. M. Ardran and H. E. Crooks, " The measurement of patient dose.," Br. J. Radiol. BJRAAP 0007-1285 38, 766-770 (1965). 10.1259/0007-1285-38-454-766
    • (1965) Br. J. Radiol. , vol.38 , pp. 766-770
    • Ardran, G.M.1    Crooks, H.E.2
  • 28
    • 85027221048 scopus 로고    scopus 로고
    • accessed 30 January.
    • http://physics.nist.gov/PhysRefData/XrayMassCoef/cover.html, accessed 30 January 2009.
    • (2009)
  • 30
    • 0022455545 scopus 로고
    • Scatter correction algorithm for digitally acquired radiographics: Theory and results
    • DOI 10.1118/1.595920
    • J. M. Boone, " Scatter algorithm for digitally acquired radiographs: Theory and results.," Med. Phys. MPHYA6 0094-2405 13 (3), 319-328 (1986). 10.1118/1.595920 (Pubitemid 16062263)
    • (1986) Medical Physics , vol.13 , Issue.3 , pp. 319-328
    • Boone, J.M.1
  • 31
    • 58149115069 scopus 로고    scopus 로고
    • The influence of bowtie filtration on cone-beam CT image quality
    • MPHYA6 0094-2405 (),. 10.1118/1.3017470
    • N. Mail, D. J. Moseley, J. H. Siewerdsen, and D. A. Jaffray, " The influence of bowtie filtration on cone-beam CT image quality.," Med. Phys. MPHYA6 0094-2405 36 (1), 22-32 (2009). 10.1118/1.3017470
    • (2009) Med. Phys. , vol.36 , Issue.1 , pp. 22-32
    • Mail, N.1    Moseley, D.J.2    Siewerdsen, J.H.3    Jaffray, D.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.