-
1
-
-
0029809781
-
Magnetic resonance images lipid, fibrous, calcified, hemorrhagic, and thrombotic components of human atherosclerosis in vivo
-
Toussaint JF, LaMuraglia GM, Southern JF, Fuster V, Kantor HL. Magnetic resonance images lipid, fibrous, calcified, hemorrhagic, and thrombotic components of human atherosclerosis in vivo. Circulation 1996;94:932-938.
-
(1996)
Circulation
, vol.94
, pp. 932-938
-
-
Toussaint, J.F.1
LaMuraglia, G.M.2
Southern, J.F.3
Fuster, V.4
Kantor, H.L.5
-
2
-
-
0022444930
-
Proton relaxation times in arterial wall and atheromatous lesions in man
-
Soila K, Nummi P, Ekfors T, Viamonte M, Kormano M. Proton relaxation times in arterial wall and atheromatous lesions in man. Invest Radiol 1986;21:411-415.
-
(1986)
Invest Radiol
, vol.21
, pp. 411-415
-
-
Soila, K.1
Nummi, P.2
Ekfors, T.3
Viamonte, M.4
Kormano, M.5
-
3
-
-
0032724813
-
The diagnostic accuracy of ex vivo MRI for human atherosclerotic plaque characterization
-
Shinnar M, Fallon JT, Wehrli S, et al. The diagnostic accuracy of ex vivo MRI for human atherosclerotic plaque characterization. Arterioscler Thromb Vasc Biol 1999;19:2756-2761.
-
(1999)
Arterioscler Thromb Vasc Biol
, vol.19
, pp. 2756-2761
-
-
Shinnar, M.1
Fallon, J.T.2
Wehrli, S.3
-
4
-
-
0035940373
-
In vivo accuracy of multispectral magnetic resonance imaging for identifying lipidrich necrotic cores and intraplaque hemorrhage in advanced human carotid plaques
-
Yuan C, Mitsumori LM, Ferguson MS, et al. In vivo accuracy of multispectral magnetic resonance imaging for identifying lipidrich necrotic cores and intraplaque hemorrhage in advanced human carotid plaques. Circulation 2001;104:2051-2056.
-
(2001)
Circulation
, vol.104
, pp. 2051-2056
-
-
Yuan, C.1
Mitsumori, L.M.2
Ferguson, M.S.3
-
5
-
-
33646183558
-
Multislice dark-blood carotid artery wall imaging: A 1.5 T and 3.0 T comparison
-
Koktzoglou I, Chung Y, Mani V, et al. Multislice dark-blood carotid artery wall imaging: a 1.5 T and 3.0 T comparison. J Magn Reson Imaging 2006;23:699-705.
-
(2006)
J Magn Reson Imaging
, vol.23
, pp. 699-705
-
-
Koktzoglou, I.1
Chung, Y.2
Mani, V.3
-
6
-
-
33646200963
-
Multicontrast blackblood MRI of carotid arteries: Comparison between 1.5 and 3 Tesla magnetic field strengths
-
Yarnykh VL, Terashima M, Hayes CE, et al. Multicontrast blackblood MRI of carotid arteries: comparison between 1.5 and 3 Tesla magnetic field strengths. J Magn Reson Imaging 2006;23: 691-698.
-
(2006)
J Magn Reson Imaging
, vol.23
, pp. 691-698
-
-
Yarnykh, V.L.1
Terashima, M.2
Hayes, C.E.3
-
7
-
-
10044268779
-
Triple contrast technique for black blood imaging with double inversion preparation
-
Kim SE, Kholmovski EG, Jeong EK, Buswell HR, Tsuruda JS, Parker DL. Triple contrast technique for black blood imaging with double inversion preparation. Magn Reson Med 2004;52: 1379-1387.
-
(2004)
Magn Reson Med
, vol.52
, pp. 1379-1387
-
-
Kim, S.E.1
Kholmovski, E.G.2
Jeong, E.K.3
Buswell, H.R.4
Tsuruda, J.S.5
Parker, D.L.6
-
8
-
-
2942705883
-
Rapid extended coverage simultaneous multisection black-blood vessel wall MR imaging
-
Mani V, Itskovich VV, Szimtenings M, et al. Rapid extended coverage simultaneous multisection black-blood vessel wall MR imaging. Radiology 2004;232:281-288.
-
(2004)
Radiology
, vol.232
, pp. 281-288
-
-
Mani, V.1
Itskovich, V.V.2
Szimtenings, M.3
-
9
-
-
0036184749
-
Multislice double inversion pulse sequence for efficient black-blood MRI
-
Song HK, Wright AC, Wolf RL, Wehrli FW. Multislice double inversion pulse sequence for efficient black-blood MRI. Magn Reson Med 2002;47:616-620.
-
(2002)
Magn Reson Med
, vol.47
, pp. 616-620
-
-
Song, H.K.1
Wright, A.C.2
Wolf, R.L.3
Wehrli, F.W.4
-
10
-
-
0037380401
-
Multislice double inversion-recovery black-blood imaging with simultaneous slice reinversion
-
Yarnykh VL, Yuan C. Multislice double inversion-recovery black-blood imaging with simultaneous slice reinversion. J Magn Reson Imaging 2003;17:478-483.
-
(2003)
J Magn Reson Imaging
, vol.17
, pp. 478-483
-
-
Yarnykh, V.L.1
Yuan, C.2
-
11
-
-
1842433586
-
Parallel and nonparallel simultaneous multislice black-blood double inversion recovery techniques for vessel wall imaging
-
Itskovich VV, Mani V, Mizsei G, et al. Parallel and nonparallel simultaneous multislice black-blood double inversion recovery techniques for vessel wall imaging. J Magn Reson Imaging 2004; 19:459-467.
-
(2004)
J Magn Reson Imaging
, vol.19
, pp. 459-467
-
-
Itskovich, V.V.1
Mani, V.2
Mizsei, G.3
-
12
-
-
75749155444
-
Increased slice coverage for black blood arterial wall imaging with double-inversion FSE
-
Kyoto, Japan, Abstract 450
-
Hardy CJ, Dixon WT, Blezek DJ, Saranathan M, Zong X, Raman SV. Increased slice coverage for black blood arterial wall imaging with double-inversion FSE. In: Proceedings of the 12th Annual Meeting of ISMRM, Kyoto, Japan, 2004 (Abstract 450).
-
(2004)
Proceedings of the 12th Annual Meeting of ISMRM
-
-
Hardy, C.J.1
Dixon, W.T.2
Blezek, D.J.3
Saranathan, M.4
Zong, X.5
Raman, S.V.6
-
13
-
-
0038640448
-
Volume-selective 3D turbo spin echo imaging for vascular wall imaging and distensibility measurement
-
Crowe LA, Gatehouse P, Yang GZ, et al. Volume-selective 3D turbo spin echo imaging for vascular wall imaging and distensibility measurement. J Magn Reson Imaging 2003;17:572-580.
-
(2003)
J Magn Reson Imaging
, vol.17
, pp. 572-580
-
-
Crowe, L.A.1
Gatehouse, P.2
Yang, G.Z.3
-
14
-
-
0023911454
-
Rapid local rectangular views and magnifications: Reduced phase encoding of orthogonally excited spin echoes
-
Conturo TE, Price RR, Beth AH. Rapid local rectangular views and magnifications: reduced phase encoding of orthogonally excited spin echoes. Magn Reson Med 1988;6:418-429.
-
(1988)
Magn Reson Med
, vol.6
, pp. 418-429
-
-
Conturo, T.E.1
Price, R.R.2
Beth, A.H.3
-
15
-
-
31044435179
-
Strategies for inner volume 3D fast spin echo magnetic resonance imaging using nonselective refocusing radio frequency pulses
-
Mitsouras D, Mulkern RV, Rybicki FJ. Strategies for inner volume 3D fast spin echo magnetic resonance imaging using nonselective refocusing radio frequency pulses. Med Phys 2006;33: 173-186.
-
(2006)
Med Phys
, vol.33
, pp. 173-186
-
-
Mitsouras, D.1
Mulkern, R.V.2
Rybicki, F.J.3
-
16
-
-
33644835410
-
Elimination of residual blood flow-related signal in 3D volumeselective TSE arterial wall imaging using velocity-sensitive phase reconstruction
-
Crowe LA, Varghese A, Mohiaddin RH, Yang GZ, Firmin DN. Elimination of residual blood flow-related signal in 3D volumeselective TSE arterial wall imaging using velocity-sensitive phase reconstruction. J Magn Reson Imaging 2006;23:416-421.
-
(2006)
J Magn Reson Imaging
, vol.23
, pp. 416-421
-
-
Crowe, L.A.1
Varghese, A.2
Mohiaddin, R.H.3
Yang, G.Z.4
Firmin, D.N.5
-
17
-
-
0031899393
-
On the nature and reduction of plaquemimicking flow artifacts in black blood MRI of the carotid bifurcation
-
Steinman DA, Rutt BK. On the nature and reduction of plaquemimicking flow artifacts in black blood MRI of the carotid bifurcation. Magn Reson Med 1998;39:635-641.
-
(1998)
Magn Reson Med
, vol.39
, pp. 635-641
-
-
Steinman, D.A.1
Rutt, B.K.2
-
18
-
-
2942670674
-
Lipid-rich atherosclerotic plaques detected by gadofluorine-enhanced in vivo magnetic resonance imaging
-
Sirol M, Itskovich VV, Mani V, et al. Lipid-rich atherosclerotic plaques detected by gadofluorine-enhanced in vivo magnetic resonance imaging. Circulation 2004;109:2890-2896.
-
(2004)
Circulation
, vol.109
, pp. 2890-2896
-
-
Sirol, M.1
Itskovich, V.V.2
Mani, V.3
-
19
-
-
33845904636
-
Diffusion-prepared segmented steady-state free precession: Application to 3D black-blood cardiovascular magnetic resonance of the thoracic aorta and carotid artery walls
-
Koktzoglou I, Li D. Diffusion-prepared segmented steady-state free precession: Application to 3D black-blood cardiovascular magnetic resonance of the thoracic aorta and carotid artery walls. J Cardiovasc Magn Reson 2007;9:33-42.
-
(2007)
J Cardiovasc Magn Reson
, vol.9
, pp. 33-42
-
-
Koktzoglou, I.1
Li, D.2
-
20
-
-
35948971057
-
Improved suppression of plaque-mimicking artifacts in blackblood carotid atherosclerosis imaging using a multislice motionsensitized driven equilibrium (MSDE) turbo spin-echo (TSE) sequence
-
Wang J, Yarnykh VL, Hatsukami T, Chu B, Balu N, Yuan C. Improved suppression of plaque-mimicking artifacts in blackblood carotid atherosclerosis imaging using a multislice motionsensitized driven equilibrium (MSDE) turbo spin-echo (TSE) sequence. Magn Reson Med 2007;58:973-981.
-
(2007)
Magn Reson Med
, vol.58
, pp. 973-981
-
-
Wang, J.1
Yarnykh, V.L.2
Hatsukami, T.3
Chu, B.4
Balu, N.5
Yuan, C.6
-
21
-
-
0026320313
-
Fast selective black blood MR imaging
-
Edelman RR, Chien D, Kim D. Fast selective black blood MR imaging. Radiology 1991;181:655-660.
-
(1991)
Radiology
, vol.181
, pp. 655-660
-
-
Edelman, R.R.1
Chien, D.2
Kim, D.3
-
22
-
-
75749158551
-
Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla
-
Lu H, Fuster V, Clingman C, Golay X, VanZijl PCM. Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla. Circulation 2000;102:506-510.
-
(2000)
Circulation
, vol.102
, pp. 506-510
-
-
Lu, H.1
Fuster, V.2
Clingman, C.3
Golay, X.4
VanZijl, P.C.M.5
-
23
-
-
0034255293
-
Noninvasive in vivo human coronary artery lumen and wall imaging using black-blood magnetic resonance imaging
-
Fayad ZA, Fuster V, Fallon JT, et al. Noninvasive in vivo human coronary artery lumen and wall imaging using black-blood magnetic resonance imaging. Circulation 2000;102:506-510.
-
(2000)
Circulation
, vol.102
, pp. 506-510
-
-
Fayad, Z.A.1
Fuster, V.2
Fallon, J.T.3
-
25
-
-
27644437673
-
Comparison of gated and non-gated fast multislice black-blood carotid imaging using rapid extended coverage and inflow/outflow saturation techniques
-
Mani V, Itskovich VV, Aguiar SH, et al. Comparison of gated and non-gated fast multislice black-blood carotid imaging using rapid extended coverage and inflow/outflow saturation techniques. J Magn Reson Imaging 2005;22:628-633.
-
(2005)
J Magn Reson Imaging
, vol.22
, pp. 628-633
-
-
Mani, V.1
Itskovich, V.V.2
Aguiar, S.H.3
-
26
-
-
0035200124
-
Improved common carotid elasticity and intima-media thickness measurements from computer analysis of sequential ultrasound frames
-
Selzer RH, Mack WJ, Lee PL, Fu HK, Hodis HN. Improved common carotid elasticity and intima-media thickness measurements from computer analysis of sequential ultrasound frames. Atherosclerosis 2001;154:185-193.
-
(2001)
Atherosclerosis
, vol.154
, pp. 185-193
-
-
Selzer, R.H.1
Mack, W.J.2
Lee, P.L.3
Fu, H.K.4
Hodis, H.N.5
|