메뉴 건너뛰기




Volumn 51, Issue 2, 2010, Pages 198-203

Definition of vascular territories on myocardial perfusion images by integration with true coronary anatomy: A hybrid PET/CT analysis

Author keywords

CT coronary angiography; Hybrid imaging; PET CT; Vascular territories

Indexed keywords

ADULT; ANATOMY; ANIMAL EXPERIMENT; ARTICLE; CARDIOVASCULAR SYSTEM; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; COMPUTER ASSISTED EMISSION TOMOGRAPHY; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; CORONARY ARTERY; CORONARY ARTERY CIRCUMFLEX BRANCH; CORONARY ARTERY DISEASE; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; DOG; EX VIVO STUDY; FEMALE; HEART MUSCLE PERFUSION; HUMAN; MAJOR CLINICAL STUDY; MALE; MEDICAL SOCIETY; NONHUMAN; POSITRON EMISSION TOMOGRAPHY; PRIORITY JOURNAL; RIGHT CORONARY ARTERY;

EID: 75749143512     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: 10.2967/jnumed.109.067488     Document Type: Article
Times cited : (78)

References (24)
  • 1
    • 0037192118 scopus 로고    scopus 로고
    • Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association
    • Cerqueira MD, Weissman NJ, Dilsizian V, et al. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation. 2002;105:539-542.
    • (2002) Circulation , vol.105 , pp. 539-542
    • Cerqueira, M.D.1    Weissman, N.J.2    Dilsizian, V.3
  • 2
    • 26844552946 scopus 로고    scopus 로고
    • ACCF/ASNC appropriateness criteria for single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI): A report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group and the American Society of Nuclear Cardiology endorsed by the American Heart Association
    • Brindis RG, Douglas PS, Hendel RC, et al. ACCF/ASNC appropriateness criteria for single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI): a report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group and the American Society of Nuclear Cardiology endorsed by the American Heart Association. J Am Coll Cardiol. 2005;46:1587-1605.
    • (2005) J Am Coll Cardiol , vol.46 , pp. 1587-1605
    • Brindis, R.G.1    Douglas, P.S.2    Hendel, R.C.3
  • 3
    • 34147101153 scopus 로고    scopus 로고
    • New technology for noninvasive evaluation of coronary artery disease
    • Di Carli MF, Hachamovitch R. New technology for noninvasive evaluation of coronary artery disease. Circulation. 2007;115:1464-1480.
    • (2007) Circulation , vol.115 , pp. 1464-1480
    • Di Carli, M.F.1    Hachamovitch, R.2
  • 4
    • 36148932978 scopus 로고    scopus 로고
    • Relationship between CT coronary angiography and stress perfusion imaging in patients with suspected ischemic heart disease assessed by integrated PET-CT imaging
    • Di Carli MF, Dorbala S, Curillova Z, et al. Relationship between CT coronary angiography and stress perfusion imaging in patients with suspected ischemic heart disease assessed by integrated PET-CT imaging. J Nucl Cardiol. 2007;14:799-809.
    • (2007) J Nucl Cardiol , vol.14 , pp. 799-809
    • Di Carli, M.F.1    Dorbala, S.2    Curillova, Z.3
  • 5
    • 34249775027 scopus 로고    scopus 로고
    • Accuracy of 64-slice CTangiography for the detection of functionally relevant coronary stenoses as assessed with myocardial perfusion SPECT
    • Gaemperli O, Schepis T, Koepfli P, et al. Accuracy of 64-slice CTangiography for the detection of functionally relevant coronary stenoses as assessed with myocardial perfusion SPECT. Eur J NuclMed Mol Imaging. 2007;34:1162-1171.
    • (2007) Eur J NuclMed Mol Imaging , vol.34 , pp. 1162-1171
    • Gaemperli, O.1    Schepis, T.2    Koepfli, P.3
  • 6
    • 25444483065 scopus 로고    scopus 로고
    • Comparison of spiral multidetector CT angiography and myocardial perfusion imaging in the noninvasive detection of functionally relevant coronary artery lesions: First clinical experiences
    • Hacker M, Jakobs T, Matthiesen F, et al. Comparison of spiral multidetector CT angiography and myocardial perfusion imaging in the noninvasive detection of functionally relevant coronary artery lesions: first clinical experiences. J Nucl Med. 2005;46:1294-1300.
    • (2005) J Nucl Med , vol.46 , pp. 1294-1300
    • Hacker, M.1    Jakobs, T.2    Matthiesen, F.3
  • 7
    • 33847655108 scopus 로고    scopus 로고
    • Integrated single-photon emission computed tomography and computed tomography coronary angiography for the assessment of hemodynamically significant coronary artery lesions
    • Rispler S, Keidar Z, Ghersin E, et al. Integrated single-photon emission computed tomography and computed tomography coronary angiography for the assessment of hemodynamically significant coronary artery lesions. J Am Coll Cardiol. 2007;49:1059-1067.
    • (2007) J Am Coll Cardiol , vol.49 , pp. 1059-1067
    • Rispler, S.1    Keidar, Z.2    Ghersin, E.3
  • 8
    • 33845329177 scopus 로고    scopus 로고
    • Relationship between noninvasive coronary angiography with multi-slice computed tomography and myocardial perfusion imaging
    • Schuijf JD, Wijns W, Jukema JW, et al. Relationship between noninvasive coronary angiography with multi-slice computed tomography and myocardial perfusion imaging. J Am Coll Cardiol. 2006;48:2508-2514.
    • (2006) J Am Coll Cardiol , vol.48 , pp. 2508-2514
    • Schuijf, J.D.1    Wijns, W.2    Jukema, J.W.3
  • 9
    • 59749092047 scopus 로고    scopus 로고
    • Prognostic value of multislice computed tomography and gated single-photon emission computed tomography in patients with suspected coronary artery disease
    • van Werkhoven JM, Schuijf JD, Gaemperli O, et al. Prognostic value of multislice computed tomography and gated single-photon emission computed tomography in patients with suspected coronary artery disease. J Am Coll Cardiol. 2009;53:623-632.
    • (2009) J Am Coll Cardiol , vol.53 , pp. 623-632
    • van Werkhoven, J.M.1    Schuijf, J.D.2    Gaemperli, O.3
  • 10
    • 34249825903 scopus 로고    scopus 로고
    • Validation of a new cardiac image fusion software for three-dimensional integration of myocardial perfusion SPECT and stand-alone 64-slice CT angiography
    • Gaemperli O, Schepis T, Kalff V, et al. Validation of a new cardiac image fusion software for three-dimensional integration of myocardial perfusion SPECT and stand-alone 64-slice CT angiography. Eur J Nucl Med Mol Imaging. 2007;34: 1097-1106.
    • (2007) Eur J Nucl Med Mol Imaging , vol.34 , pp. 1097-1106
    • Gaemperli, O.1    Schepis, T.2    Kalff, V.3
  • 11
    • 34250654581 scopus 로고    scopus 로고
    • Cardiac image fusion from stand-alone SPECT and CT: Clinical experience
    • Gaemperli O, Schepis T, Valenta I, et al. Cardiac image fusion from stand-alone SPECT and CT: clinical experience. J Nucl Med. 2007;48:696-703.
    • (2007) J Nucl Med , vol.48 , pp. 696-703
    • Gaemperli, O.1    Schepis, T.2    Valenta, I.3
  • 12
    • 38349117091 scopus 로고    scopus 로고
    • CT-based attenuation correction in 82Rb-myocardial perfusion PET-CT: Incidence of misalignment and effect on regional tracer distribution
    • Lautamaki R, Brown TL, Merrill J, Bengel FM. CT-based attenuation correction in 82Rb-myocardial perfusion PET-CT: incidence of misalignment and effect on regional tracer distribution. Eur J Nucl Med Mol Imaging. 2008;35:305-310.
    • (2008) Eur J Nucl Med Mol Imaging , vol.35 , pp. 305-310
    • Lautamaki, R.1    Brown, T.L.2    Merrill, J.3    Bengel, F.M.4
  • 13
    • 54449086666 scopus 로고    scopus 로고
    • Lowering radiation dose for integrated assessment of coronary morphology and physiology: First experience with step-and-shoot CT angiography in a rubidium 82 PET-CT protocol
    • Javadi M, Mahesh M, McBride G, et al. Lowering radiation dose for integrated assessment of coronary morphology and physiology: first experience with step-and-shoot CT angiography in a rubidium 82 PET-CT protocol. J Nucl Cardiol. 2008;15:783-790.
    • (2008) J Nucl Cardiol , vol.15 , pp. 783-790
    • Javadi, M.1    Mahesh, M.2    McBride, G.3
  • 14
    • 0031670083 scopus 로고    scopus 로고
    • Reproducibility of polar map generation and assessment of defect severity and extent assessment in myocardial perfusion imaging using positron emission tomography
    • Nekolla SG, Miethaner C, Nguyen N, Ziegler SI, Schwaiger M. Reproducibility of polar map generation and assessment of defect severity and extent assessment in myocardial perfusion imaging using positron emission tomography. Eur J Nucl Med. 1998;25:1313-1321.
    • (1998) Eur J Nucl Med , vol.25 , pp. 1313-1321
    • Nekolla, S.G.1    Miethaner, C.2    Nguyen, N.3    Ziegler, S.I.4    Schwaiger, M.5
  • 15
    • 62149148841 scopus 로고    scopus 로고
    • Rubidium-82 PET-CT for quantitative assessment of myocardial blood flow: Validation in a canine model of coronary artery stenosis
    • Lautamaki R, George RT, Kitagawa K, et al. Rubidium-82 PET-CT for quantitative assessment of myocardial blood flow: validation in a canine model of coronary artery stenosis. Eur J Nucl Med Mol Imaging. 2009;36:576-586.
    • (2009) Eur J Nucl Med Mol Imaging , vol.36 , pp. 576-586
    • Lautamaki, R.1    George, R.T.2    Kitagawa, K.3
  • 16
    • 34447313914 scopus 로고    scopus 로고
    • Attenuation correction in myocardial perfusion SPECT/CT: Effects of misregistration and value of reregistration
    • Goetze S, Brown TL, Lavely WC, Zhang Z, Bengel FM. Attenuation correction in myocardial perfusion SPECT/CT: effects of misregistration and value of reregistration. J Nucl Med. 2007;48:1090-1095.
    • (2007) J Nucl Med , vol.48 , pp. 1090-1095
    • Goetze, S.1    Brown, T.L.2    Lavely, W.C.3    Zhang, Z.4    Bengel, F.M.5
  • 17
    • 33845373161 scopus 로고    scopus 로고
    • Use of coronary calcium score scans from stand-alone multislice computed tomography for attenuation correction of myocardial perfusion SPECT
    • Schepis T, Gaemperli O, Koepfli P, et al. Use of coronary calcium score scans from stand-alone multislice computed tomography for attenuation correction of myocardial perfusion SPECT. Eur J Nucl Med Mol Imaging. 2007;34:11-19.
    • (2007) Eur J Nucl Med Mol Imaging , vol.34 , pp. 11-19
    • Schepis, T.1    Gaemperli, O.2    Koepfli, P.3
  • 18
    • 41649101202 scopus 로고    scopus 로고
    • Interrelation of coronary calcification, myocardial ischemia, and outcomes in patients with intermediate likelihood of coronary artery disease: A combined positron emission tomography/computed tomography study
    • Schenker MP, Dorbala S, Hong EC, et al. Interrelation of coronary calcification, myocardial ischemia, and outcomes in patients with intermediate likelihood of coronary artery disease: a combined positron emission tomography/computed tomography study. Circulation. 2008;117:1693-1700.
    • (2008) Circulation , vol.117 , pp. 1693-1700
    • Schenker, M.P.1    Dorbala, S.2    Hong, E.C.3
  • 19
    • 67650004076 scopus 로고    scopus 로고
    • Diagnostic performance of fusion of myocardial perfusion imaging (MPI) and computed tomography coronary angiography
    • Santana CA, Garcia EV, Faber TL, et al. Diagnostic performance of fusion of myocardial perfusion imaging (MPI) and computed tomography coronary angiography. J Nucl Cardiol. 2009;16:201-211.
    • (2009) J Nucl Cardiol , vol.16 , pp. 201-211
    • Santana, C.A.1    Garcia, E.V.2    Faber, T.L.3
  • 20
    • 28544444396 scopus 로고    scopus 로고
    • Correspondence between left ventricular 17 myocardial segments and coronary arteries
    • Pereztol-Valdes O, Candell-Riera J, Santana-Boado C, et al. Correspondence between left ventricular 17 myocardial segments and coronary arteries. Eur Heart J. 2005;26:2637-2643.
    • (2005) Eur Heart J , vol.26 , pp. 2637-2643
    • Pereztol-Valdes, O.1    Candell-Riera, J.2    Santana-Boado, C.3
  • 21
    • 43749111812 scopus 로고    scopus 로고
    • Correspondence between the 17-segment model and coronary arterial anatomy using contrast-enhanced cardiac magnetic resonance imaging
    • Ortiz-Perez JT, Rodriguez J, Meyers SN, Lee DC, Davidson C, Wu E. Correspondence between the 17-segment model and coronary arterial anatomy using contrast-enhanced cardiac magnetic resonance imaging. JACC Cardiovasc Imaging. 2008;1:282-293.
    • (2008) JACC Cardiovasc Imaging , vol.1 , pp. 282-293
    • Ortiz-Perez, J.T.1    Rodriguez, J.2    Meyers, S.N.3    Lee, D.C.4    Davidson, C.5    Wu, E.6
  • 22
    • 2642573585 scopus 로고    scopus 로고
    • Three-dimensional fusion of coronary arteries with myocardial perfusion distributions: Clinical validation
    • Faber TL, Santana CA, Garcia EV, et al. Three-dimensional fusion of coronary arteries with myocardial perfusion distributions: clinical validation. J Nucl Med. 2004;45:745-753.
    • (2004) J Nucl Med , vol.45 , pp. 745-753
    • Faber, T.L.1    Santana, C.A.2    Garcia, E.V.3
  • 23
    • 68049129738 scopus 로고    scopus 로고
    • New software methods to cope with reduced counting statistics: Shorter SPECT acquisitions and many more possibilities
    • Depuey EG. New software methods to cope with reduced counting statistics: shorter SPECT acquisitions and many more possibilities. J Nucl Cardiol. 2009;16:335-338.
    • (2009) J Nucl Cardiol , vol.16 , pp. 335-338
    • Depuey, E.G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.