메뉴 건너뛰기




Volumn 2009, Issue , 2009, Pages

Circle plus partial helical scan scheme for a flat panel detector-based cone beam breast x-ray CT

Author keywords

[No Author keywords available]

Indexed keywords

3-D IMAGE; BREAST IMAGING; BREAST PHANTOM; CIRCULAR SCANNING; CONE ANGLE; CONE BEAM; CONE-BEAM BREAST CT; FLAT PANEL DETECTORS; FUNCTIONAL IMAGING; GEOMETRICAL CONFIGURATIONS; GEOMETRICAL DISTORTION; POTENTIAL APPLICATIONS; RECONSTRUCTED IMAGE; RECONSTRUCTION IMAGE; SPATIAL RESOLUTION; STRAIGHT LINES; X-RAY CT; X-RAY PROJECTIONS;

EID: 75649121865     PISSN: 16874188     EISSN: 16874196     Source Type: Journal    
DOI: 10.1155/2009/637867     Document Type: Article
Times cited : (6)

References (22)
  • 1
    • 0035999405 scopus 로고    scopus 로고
    • Cone-beam volume CT breast imaging: Feasibility study
    • Chen B., Ning R., Cone-beam volume CT breast imaging: feasibility study Medical Physics 2002 29 5 755 770
    • (2002) Medical Physics , vol.29 , Issue.5 , pp. 755-770
    • Chen, B.1    Ning, R.2
  • 2
    • 0036033581 scopus 로고    scopus 로고
    • Investigation of optimal kVp settings for CT mammography using a flat panel detector
    • Medical Imaging 2002: Physics of Medical Imaging February 2002 San Diego, Calif, USA
    • Glick S., Vedantham S., Karellas A., Investigation of optimal kVp settings for CT mammography using a flat panel detector 4682 Medical Imaging 2002: Physics of Medical Imaging February 2002 San Diego, Calif, USA 392 402 Proceedings of SPIE
    • Proceedings of SPIE , vol.4682 , pp. 392-402
    • Glick, S.1    Vedantham, S.2    Karellas, A.3
  • 3
    • 23844455030 scopus 로고    scopus 로고
    • Investigation of cone-beam acquisitions implemented using a novel dedicated mammotomography system with unique arbitrary orbit capability
    • Medical Imaging 2005: Physics of Medical Imaging February 2005 San Diego, Calif, USA
    • McKinley R. L., Brzymialkiewicz C. N., Madhav P., Tornai M. P., Investigation of cone-beam acquisitions implemented using a novel dedicated mammotomography system with unique arbitrary orbit capability 5745 Medical Imaging 2005: Physics of Medical Imaging February 2005 San Diego, Calif, USA 609 617 Proceedings of SPIE
    • Proceedings of SPIE , vol.5745 , pp. 609-617
    • McKinley, R.L.1    Brzymialkiewicz, C.N.2    Madhav, P.3    Tornai, M.P.4
  • 4
    • 23844551628 scopus 로고    scopus 로고
    • Performance assessment of a pendant-geometry CT scanner for breast cancer detection
    • Medical Imaging 2005: Physics of Medical Imaging February 2005 San Diego, Calif, USA
    • Boone J. M., Kwan A. L. C., Nelson T. R., Performance assessment of a pendant-geometry CT scanner for breast cancer detection 5745 Medical Imaging 2005: Physics of Medical Imaging February 2005 San Diego, Calif, USA 319 323 Proceedings of SPIE
    • Proceedings of SPIE , vol.5745 , pp. 319-323
    • Boone, J.M.1    Kwan, A.L.C.2    Nelson, T.R.3
  • 5
    • 0035190741 scopus 로고    scopus 로고
    • Dedicated breast CT: Radiation dose and image quality evaluation
    • Boone J. M., Nelson T. R., Lindfors K. K., Seibert J. A., Dedicated breast CT: radiation dose and image quality evaluation Radiology 2001 221 3 657 667
    • (2001) Radiology , vol.221 , Issue.3 , pp. 657-667
    • Boone, J.M.1    Nelson, T.R.2    Lindfors, K.K.3    Seibert, J.A.4
  • 6
    • 33745373479 scopus 로고    scopus 로고
    • Preliminary investigation of dose for a dedicated mammotomography system
    • Medical Imaging 2006: Physics of Medical Imaging February 2006 San Diego, Calif, USA
    • McKinley R. L., Tornai M. P., Preliminary investigation of dose for a dedicated mammotomography system 6142 Medical Imaging 2006: Physics of Medical Imaging February 2006 San Diego, Calif, USA 1 9 Proceedings of SPIE
    • Proceedings of SPIE , vol.6142 , pp. 1-9
    • McKinley, R.L.1    Tornai, M.P.2
  • 9
    • 0020764170 scopus 로고
    • Inversion formula for cone-beam reconstruction
    • Tuy H. K., Inversion formula for cone-beam reconstruction SIAM Journal on Applied Mathematics 1983 43 3 546 552
    • (1983) SIAM Journal on Applied Mathematics , vol.43 , Issue.3 , pp. 546-552
    • Tuy, H.K.1
  • 12
    • 0001211585 scopus 로고    scopus 로고
    • An improved cone-beam reconstruction algorithm for the circular orbit
    • Hu H., An improved cone-beam reconstruction algorithm for the circular orbit Scanning 1996 18 572 581
    • (1996) Scanning , vol.18 , pp. 572-581
    • Hu, H.1
  • 13
    • 9744276664 scopus 로고    scopus 로고
    • Image reconstruction for the circle and line trajectory
    • Katsevich A., Image reconstruction for the circle and line trajectory Physics in Medicine and Biology 2004 49 22 5059 5072
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.22 , pp. 5059-5072
    • Katsevich, A.1
  • 15
    • 0033181294 scopus 로고    scopus 로고
    • A cone-beam reconstruction algorithm for circle-plus-arc data-acquisition geometry
    • Wang X., Ning R., A cone-beam reconstruction algorithm for circle-plus-arc data-acquisition geometry IEEE Transactions on Medical Imaging 1999 18 9 815 824
    • (1999) IEEE Transactions on Medical Imaging , vol.18 , Issue.9 , pp. 815-824
    • Wang, X.1    Ning, R.2
  • 16
    • 0034977534 scopus 로고    scopus 로고
    • A cone beam filtered backprojection (CB-FBP) reconstruction algorithm for a circle-plus-two-arc orbit
    • Tang X., Ning R., A cone beam filtered backprojection (CB-FBP) reconstruction algorithm for a circle-plus-two-arc orbit Medical Physics 2001 28 6 1042 1055
    • (2001) Medical Physics , vol.28 , Issue.6 , pp. 1042-1055
    • Tang, X.1    Ning, R.2
  • 17
    • 0026552271 scopus 로고
    • A cone-beam tomography algorithm for orthogonal circle-and-line orbit
    • Zeng G. L., Gullberg G. T., A cone-beam tomography algorithm for orthogonal circle-and-line orbit Physics in Medicine and Biology 1992 37 3 563 577
    • (1992) Physics in Medicine and Biology , vol.37 , Issue.3 , pp. 563-577
    • Zeng, G.L.1    Gullberg, G.T.2
  • 20
    • 0346752328 scopus 로고    scopus 로고
    • Exact helical reconstruction using native cone-beam geometries
    • Noo F., Pack J., Heuscher D., Exact helical reconstruction using native cone-beam geometries Physics in Medicine and Biology 2003 48 23 3787 3818
    • (2003) Physics in Medicine and Biology , vol.48 , Issue.23 , pp. 3787-3818
    • Noo, F.1    Pack, J.2    Heuscher, D.3
  • 21
    • 3142535242 scopus 로고    scopus 로고
    • Studies on implementation of the Katsevich algorithm for spiral cone-beam CT
    • Yu H., Wang G., Studies on implementation of the Katsevich algorithm for spiral cone-beam CT Journal of X-Ray Science and Technology 2004 12 2 97 116
    • (2004) Journal of X-Ray Science and Technology , vol.12 , Issue.2 , pp. 97-116
    • Yu, H.1    Wang, G.2
  • 22
    • 23844497876 scopus 로고    scopus 로고
    • Image noise due to quantum fluctuations in flat-panel detector based cone-beam CT imaging
    • Medical Imaging 2005: Physics of Medical Imaging February 2005 San Diego, Calif, USA
    • Zhang Y., Ning R., Conover D., Yu Y., Image noise due to quantum fluctuations in flat-panel detector based cone-beam CT imaging 5745 Medical Imaging 2005: Physics of Medical Imaging February 2005 San Diego, Calif, USA 656 663 Proceedings of SPIE
    • Proceedings of SPIE , vol.5745 , pp. 656-663
    • Zhang, Y.1    Ning, R.2    Conover, D.3    Yu, Y.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.