메뉴 건너뛰기




Volumn 169, Issue SUPPL., 2009, Pages

The Double sensor-A non-invasive device to continuously monitor core temperature in humans on earth and in space

Author keywords

Circadian rhythm; Heat flux; Occupational health; Thermoregulation; Validation

Indexed keywords

ADULT; ARTICLE; BODY TEMPERATURE; HUMAN; INSTRUMENTATION; MALE; METHODOLOGY; MICROCLIMATE; MONITORING; PHYSIOLOGY; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; SKIN TEMPERATURE; THERMOGRAPHY;

EID: 75549088253     PISSN: 15699048     EISSN: 18781519     Source Type: Journal    
DOI: 10.1016/j.resp.2009.04.005     Document Type: Article
Times cited : (93)

References (13)
  • 1
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement inmethod comparison studies
    • Bland, J.M., Altman, D.G., 1999. Measuring agreement inmethod comparison studies. Stat. Methods Med. Res. 8 (2), 683-688.
    • (1999) Stat. Methods Med. Res. , vol.8 , Issue.2 , pp. 683-688
    • Bland, J.M.1    Altman, D.G.2
  • 3
    • 0000639777 scopus 로고
    • Temperature in the external auditorymeatus as an index of central temperature changes
    • Cooper, K.E., Cranston, W.I., Snell, S., 1964. Temperature in the external auditorymeatus as an index of central temperature changes. J. Appl. Physiol. 19, 1032-1035.
    • (1964) J. Appl. Physiol. , vol.19 , pp. 1032-1035
    • Cooper, K.E.1    Cranston, W.I.2    Snell, S.3
  • 4
    • 0014987164 scopus 로고
    • A new technique formonitoring the deep body temperature in man from the intact skin surface
    • Fox, R.H., Solman, A.J., 1971. A new technique formonitoring the deep body temperature in man from the intact skin surface. J. Physiol. 212 (2), 8-10.
    • (1971) J. Physiol. , vol.212 , Issue.2 , pp. 8-10
    • Fox, R.H.1    Solman, A.J.2
  • 7
    • 0025361566 scopus 로고
    • Body temperature and anaesthesia
    • Imrie, M.M., Hall, G.M., 1990. Body temperature and anaesthesia. Br. J. Anaesth. 64, 346-354.
    • (1990) Br. J. Anaesth. , vol.64 , pp. 346-354
    • Imrie, M.M.1    Hall, G.M.2
  • 8
    • 0024521543 scopus 로고
    • A concordance correlation coefficient to evaluate reproducibility
    • Lin, L.I., 1989. A concordance correlation coefficient to evaluate reproducibility. Biometrics 40, 255-268.
    • (1989) Biometrics , vol.40 , pp. 255-268
    • Lin, L.I.1
  • 9
    • 84975207356 scopus 로고    scopus 로고
    • A note on the concordance correlation coefficient
    • Lin, L.I., 2000. A note on the concordance correlation coefficient. Biometrics 56, 324-325.
    • (2000) Biometrics , vol.56 , pp. 324-325
    • Lin, L.I.1
  • 11
    • 0022541360 scopus 로고
    • Esophageal and tympanic temperature responses to core blood temperature changes during hyperthermia
    • Shiraki, K., Konda, N., Sagawa, S., 1986. Esophageal and tympanic temperature responses to core blood temperature changes during hyperthermia. J. Appl. Physiol. 61, 98-102.
    • (1986) J. Appl. Physiol. , vol.61 , pp. 98-102
    • Shiraki, K.1    Konda, N.2    Sagawa, S.3
  • 12
    • 0018853261 scopus 로고
    • Continuous field monitoring of deep body temperature from the skin surface using subject-borne portable equipment: some preliminary observations
    • Smith, P., Davies, G., Christie, M.J., 1980. Continuous field monitoring of deep body temperature from the skin surface using subject-borne portable equipment: some preliminary observations. Ergonomics 23 (1), 85-86.
    • (1980) Ergonomics , vol.23 , Issue.1 , pp. 85-86
    • Smith, P.1    Davies, G.2    Christie, M.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.