메뉴 건너뛰기




Volumn 106, Issue 12, 2009, Pages 1103-1110

Influence of antiangiogenetic therapy on retinal thickness values in age-related macular degeneration;Beeinflussung von Netzhautdickenwerten durch antiangiogenetische Therapie bei altersbedingter Makuladegeneration

Author keywords

Age related Macular Degeneration; Central retinal thickness; High definition OCT; Optical Coherence Tomography; Ranibizumab

Indexed keywords

ANGIOGENESIS INHIBITOR; MONOCLONAL ANTIBODY; RANIBIZUMAB;

EID: 75549084354     PISSN: 0941293X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00347-008-1880-2     Document Type: Article
Times cited : (6)

References (14)
  • 1
    • 48149084442 scopus 로고    scopus 로고
    • Time course of morphologic effects on different retinal compartments after ranibizumab therapy in age-related macular degeneration
    • Ahlers C, Golbaz I, Stock G et al. (2008) Time course of morphologic effects on different retinal compartments after ranibizumab therapy in age-related macular degeneration. Ophthalmology 115(8):e39-e46
    • (2008) Ophthalmology , vol.115 , Issue.8
    • Ahlers, C.1    Golbaz, I.2    Stock, G.3
  • 2
    • 41149130631 scopus 로고    scopus 로고
    • New perspectives in diagnostics: High-resolution optical coherence tomography for age-related macular degeneration
    • Ahlers C, Geitzenauer W, Simader C et al. (2008) New perspectives in diagnostics: High-resolution optical coherence tomography for age-related macular degeneration. Ophthalmologe 105(3):248-254
    • (2008) Ophthalmologe , vol.105 , Issue.3 , pp. 248-254
    • Ahlers, C.1    Geitzenauer, W.2    Simader, C.3
  • 3
    • 47849092576 scopus 로고    scopus 로고
    • The role of Stratus OCT in anti-VEGF therapy: Qualitative and quantitative assessment of neovascular AMD
    • Bolz M, Ritter M, Polak K et al. (2008) The role of Stratus OCT in anti-VEGF therapy: Qualitative and quantitative assessment of neovascular AMD. Ophthalmologe 105:650-655
    • (2008) Ophthalmologe , vol.105 , pp. 650-655
    • Bolz, M.1    Ritter, M.2    Polak, K.3
  • 4
    • 3142617365 scopus 로고    scopus 로고
    • Optical coherence tomography 3: Automatic delineation of the outer neural retinal boundary and its influence on retinal thickness measurements
    • Costa RA, Calucci D, Skaf M et al. (2004) Optical coherence tomography 3: Automatic delineation of the outer neural retinal boundary and its influence on retinal thickness measurements. Invest Ophthalmol Vis Sci 45(7):2399-2406
    • (2004) Invest Ophthalmol Vis Sci , vol.45 , Issue.7 , pp. 2399-2406
    • Costa, R.A.1    Calucci, D.2    Skaf, M.3
  • 5
    • 38649091069 scopus 로고    scopus 로고
    • State-of-the-art retinal optical coherence tomography
    • Drexler W, Fujimoto JG (2008) State-of-the-art retinal optical coherence tomography. Prog Retin Eye Res 27(1):45-88
    • (2008) Prog Retin Eye Res , vol.27 , Issue.1 , pp. 45-88
    • Drexler, W.1    Fujimoto, J.G.2
  • 6
    • 75549088986 scopus 로고    scopus 로고
    • 1Dept. of Ophthalmology, Medical University of Vienna, Vienna, Austria; 2Carl Zeiss Meditec, Inc., Dublin, CA; 3Northern California Retina and Vitreous Associates, Mountain View, CA; 4Wilmer Eye Institute, Johns Hopkins University, Baltimore, MD; 5Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami FL 2008
    • Geitzenauer W,KC Durbin M, Wieland M et al. (2008) Comparing Retinal Thickness Measurements From Cirrus Spectral-Domain and Stratus Time-Domain Optical Coherence Tomography. 1Dept. of Ophthalmology, Medical University of Vienna, Vienna, Austria; 2Carl Zeiss Meditec, Inc., Dublin, CA; 3Northern California Retina and Vitreous Associates, Mountain View, CA; 4Wilmer Eye Institute, Johns Hopkins University, Baltimore, MD; 5Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami FL 2008
    • (2008) Comparing Retinal Thickness Measurements From Cirrus Spectral-Domain and Stratus Time-Domain Optical Coherence Tomography
    • Geitzenauer, W.1    Durbin, K.C.M.2    Wieland, M.3
  • 7
    • 35148901507 scopus 로고    scopus 로고
    • Reproducibility of quantitative optical coherence tomography subanalysis in neovascular age-related macular degeneration
    • Joeres S, Tsong JW, Updike PG et al. (2007) Reproducibility of quantitative optical coherence tomography subanalysis in neovascular age-related macular degeneration. Invest Ophthalmol Vis Sci 48(9):4300-4307
    • (2007) Invest Ophthalmol Vis Sci , vol.48 , Issue.9 , pp. 4300-4307
    • Joeres, S.1    Tsong, J.W.2    Updike, P.G.3
  • 8
    • 27644479517 scopus 로고    scopus 로고
    • Comparison of ultrahigh- and standard-resolution optical coherence tomography for imaging macular pathology
    • Ko TH, Fujimoto JG, Schuman JS et al. (2005) Comparison of ultrahigh- and standard-resolution optical coherence tomography for imaging macular pathology. Ophthalmology 112(11):1922 e1-1915 e1
    • (2005) Ophthalmology , vol.112 , Issue.11 , pp. 1922-1915
    • Ko, T.H.1    Fujimoto, J.G.2    Schuman, J.S.3
  • 9
    • 57649201772 scopus 로고    scopus 로고
    • Optical coherence tomography-high resolution imaging of structure and function
    • Leitgeb RA (2007) Optical coherence tomography-high resolution imaging of structure and function. Conf Proc IEEE Eng Med Biol Soc 2007:530-532
    • (2007) Conf Proc IEEE Eng Med Biol Soc , vol.2007 , pp. 530-532
    • Leitgeb, R.A.1
  • 10
    • 33846534650 scopus 로고    scopus 로고
    • Alignment artifacts in optical coherence tomography analyzed images
    • Leung CK, Chan WM, Chong KK et al. (2007) Alignment artifacts in optical coherence tomography analyzed images. Ophthalmology 114(2): 263-270
    • (2007) Ophthalmology , vol.114 , Issue.2 , pp. 263-270
    • Leung, C.K.1    Chan, W.M.2    Chong, K.K.3
  • 11
    • 41949085490 scopus 로고    scopus 로고
    • Repeatability of stratus optical coherence tomography measures in neovascular age-related macular degeneration
    • Patel PJ, Chen FK, Ikeji F et al. (2008) Repeatability of stratus optical coherence tomography measures in neovascular age-related macular degeneration. Invest Ophthalmol Vis Sci 49(3):1084-1088
    • (2008) Invest Ophthalmol Vis Sci , vol.49 , Issue.3 , pp. 1084-1088
    • Patel, P.J.1    Chen, F.K.2    Ikeji, F.3
  • 12
    • 33847739340 scopus 로고    scopus 로고
    • Error correction and quantitative subanalysis of optical coherence tomography data using computer-assisted grading
    • Sadda SR, Joeres S, Wu Z et al. (2007) Error correction and quantitative subanalysis of optical coherence tomography data using computer-assisted grading. Invest Ophthalmol Vis Sci 48(2):839-848
    • (2007) Invest Ophthalmol Vis Sci , vol.48 , Issue.2 , pp. 839-848
    • Sadda, S.R.1    Joeres, S.2    Wu, Z.3
  • 13
    • 31644448419 scopus 로고    scopus 로고
    • Errors in retinal thickness measurements obtained by optical coherence tomography
    • Sadda SR, Wu Z, Walsh AC et al. (2006) Errors in retinal thickness measurements obtained by optical coherence tomography. Ophthalmology 113(2):285-293
    • (2006) Ophthalmology , vol.113 , Issue.2 , pp. 285-293
    • Sadda, S.R.1    Wu, Z.2    Walsh, A.C.3
  • 14
    • 27244454186 scopus 로고    scopus 로고
    • Three-dimensional ultrahigh-resolution optical coherence tomography of macular diseases
    • Schmidt-Erfurth U, Leitgeb RA, Michels S et al. (2005) Three-dimensional ultrahigh-resolution optical coherence tomography of macular diseases. Invest Ophthalmol Vis Sci 46(9):3393-3402
    • (2005) Invest Ophthalmol Vis Sci , vol.46 , Issue.9 , pp. 3393-3402
    • Schmidt-Erfurth, U.1    Leitgeb, R.A.2    Michels, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.