메뉴 건너뛰기




Volumn 87, Issue 2, 2010, Pages 703-709

Shower water heat recovery in high-rise residential buildings of Hong Kong

Author keywords

Hot water shower; Residential buildings; Waste heat recovery

Indexed keywords

FLOW OF WATER; HEAT EXCHANGERS; HOUSING; MONTE CARLO METHODS; TALL BUILDINGS; WASTE HEAT; WATER HEATERS; WATER SUPPLY;

EID: 75449109881     PISSN: 03062619     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apenergy.2009.08.008     Document Type: Article
Times cited : (141)

References (34)
  • 1
    • 52649131079 scopus 로고    scopus 로고
    • Hong Kong Electrical and Mechanical Services Department. Hong Kong: The Energy Efficiency Office
    • Hong Kong Electrical and Mechanical Services Department. Hong Kong Energy End-use Data 2007. Hong Kong: The Energy Efficiency Office; 2007.
    • (2007) Hong Kong Energy End-use Data 2007
  • 2
    • 33751291772 scopus 로고    scopus 로고
    • European residential buildings and empirical assessment of the Hellenic building stock, energy consumption, emissions and potential energy savings
    • Balaras CA, Gaglia AG, Georgopoulou E, Mirasgedis S, Sarafidis Y, Lalas DP. European residential buildings and empirical assessment of the Hellenic building stock, energy consumption, emissions and potential energy savings. Build Environ 2007;42(3):1298-314.
    • (2007) Build Environ , vol.42 , Issue.3 , pp. 1298-1314
    • Balaras, C.A.1    Gaglia, A.G.2    Georgopoulou, E.3    Mirasgedis, S.4    Sarafidis, Y.5    Lalas, D.P.6
  • 4
    • 59249088554 scopus 로고    scopus 로고
    • Annual performance of buildingintegrated photovoltaic/water-heating system for warm climate application
    • Chow TT, Chan ALS, Fong KF, Lin Z, He W, Ji J. Annual performance of buildingintegrated photovoltaic/water-heating system for warm climate application. Appl Energy 2009;86(5):689-96.
    • (2009) Appl Energy , vol.86 , Issue.5 , pp. 689-696
    • Chow, T.T.1    Chan, A.L.S.2    Fong, K.F.3    Lin, Z.4    He, W.5    Ji, J.6
  • 5
    • 36549048819 scopus 로고    scopus 로고
    • Achieving total domestic hot water production with renewable energy
    • Biaou AL, Bernier MA. Achieving total domestic hot water production with renewable energy. Build Environ 2008;43(4):651-60.
    • (2008) Build Environ , vol.43 , Issue.4 , pp. 651-660
    • Biaou, A.L.1    Bernier, M.A.2
  • 6
    • 33344454892 scopus 로고    scopus 로고
    • Residential cogeneration systems: review of the current technology
    • Onovwiona HI, Ugursal VI. Residential cogeneration systems: review of the current technology. Renew Sustain Energy Rev 2006;10(5):389-431.
    • (2006) Renew Sustain Energy Rev , vol.10 , Issue.5 , pp. 389-431
    • Onovwiona, H.I.1    Ugursal, V.I.2
  • 7
    • 33845564843 scopus 로고    scopus 로고
    • Modeling water consumption and flow rates for flushing water systems in high-rise residential buildings in Hong Kong
    • Wong LT, Mui KW. Modeling water consumption and flow rates for flushing water systems in high-rise residential buildings in Hong Kong. Build Environ 2007;42(5):2024-34.
    • (2007) Build Environ , vol.42 , Issue.5 , pp. 2024-2034
    • Wong, L.T.1    Mui, K.W.2
  • 8
    • 36949005431 scopus 로고    scopus 로고
    • Domestic water consumption benchmark development for Hong Kong
    • Mui KW, Wong LT, Law LY. Domestic water consumption benchmark development for Hong Kong. Build Serv Eng Res Technol 2007;28(4):329-35.
    • (2007) Build Serv Eng Res Technol , vol.28 , Issue.4 , pp. 329-335
    • Mui, K.W.1    Wong, L.T.2    Law, L.Y.3
  • 9
    • 0342936353 scopus 로고    scopus 로고
    • Fernández Viar P. Feasibility study for the installation of HVAC for a spa by means of energy recovery from thermal water-Part I: analysis of conditions
    • López González LM, Míguez Tabarés JL, Gándara Alvarez M, Fernández Viar P. Feasibility study for the installation of HVAC for a spa by means of energy recovery from thermal water-Part I: analysis of conditions. Renew Energy 2001;23(1):123-34.
    • (2001) Renew Energy , vol.23 , Issue.1 , pp. 123-134
    • López González, L.M.1    Míguez Tabarés, J.L.2    Gándara Alvarez, M.3
  • 10
    • 33646753146 scopus 로고    scopus 로고
    • Performances of modern domestic hot-water stores
    • Spur R, Fiala D, Nevrala D, Probert D. Performances of modern domestic hot-water stores. Appl Energy 2006;83(8):893-910.
    • (2006) Appl Energy , vol.83 , Issue.8 , pp. 893-910
    • Spur, R.1    Fiala, D.2    Nevrala, D.3    Probert, D.4
  • 11
    • 0032296604 scopus 로고    scopus 로고
    • Water heating through electric shower and energy demand
    • Prado RTA, Goncalves OM. Water heating through electric shower and energy demand. Energy Build 1998;29(1):77-82.
    • (1998) Energy Build , vol.29 , Issue.1 , pp. 77-82
    • Prado, R.T.A.1    Goncalves, O.M.2
  • 12
    • 17644402740 scopus 로고    scopus 로고
    • The field synergy (coordination) principle and its applications in enhancing single phase convective heat transfer
    • Guo ZY, Tao WQ, Shah RK. The field synergy (coordination) principle and its applications in enhancing single phase convective heat transfer. Int J Heat Mass Trans 2005;48(9):1797-807.
    • (2005) Int J Heat Mass Trans , vol.48 , Issue.9 , pp. 1797-1807
    • Guo, Z.Y.1    Tao, W.Q.2    Shah, R.K.3
  • 13
    • 29244467723 scopus 로고    scopus 로고
    • A new design approach for shell-and-tube heat exchangers using genetic algorithms from economic point of view
    • Selbas R, Ki{dotless}zi{dotless}lkan O, Reppich M. A new design approach for shell-and-tube heat exchangers using genetic algorithms from economic point of view. Chem Eng Process 2006;45(4):268-75.
    • (2006) Chem Eng Process , vol.45 , Issue.4 , pp. 268-275
    • Selbas, R.1    Kizilkan, O.2    Reppich, M.3
  • 14
    • 64649087030 scopus 로고    scopus 로고
    • The application of field synergy number in shell-andtube heat exchanger optimization design
    • Guo JF, Xu MT, Cheng L. The application of field synergy number in shell-andtube heat exchanger optimization design. Appl Energy 2009;86(10):2079-87.
    • (2009) Appl Energy , vol.86 , Issue.10 , pp. 2079-2087
    • Guo, J.F.1    Xu, M.T.2    Cheng, L.3
  • 15
    • 61749083484 scopus 로고    scopus 로고
    • A robust stochastic approach for design optimization of air cooled heat exchangers
    • Doodman AR, Fesanghary M, Hosseini R. A robust stochastic approach for design optimization of air cooled heat exchangers. Appl Energy 2009;86(7-8):1240-5.
    • (2009) Appl Energy , vol.86 , Issue.7-8 , pp. 1240-1245
    • Doodman, A.R.1    Fesanghary, M.2    Hosseini, R.3
  • 16
    • 33846068110 scopus 로고    scopus 로고
    • Seasonal autoregressive modelling of water and fuel consumptions in buildings
    • Lowry G, Bianeyin FU, Shah N. Seasonal autoregressive modelling of water and fuel consumptions in buildings. Appl Energy 2007;84(5):542-52.
    • (2007) Appl Energy , vol.84 , Issue.5 , pp. 542-552
    • Lowry, G.1    Bianeyin, F.U.2    Shah, N.3
  • 17
    • 2642538304 scopus 로고    scopus 로고
    • Modeling of the space and domestic hotwater heating energy-consumption in the residential sector using neural networks
    • Aydinalp M, Ugursal VI, Fung AS. Modeling of the space and domestic hotwater heating energy-consumption in the residential sector using neural networks. Appl Energy 2004;79(2):159-78.
    • (2004) Appl Energy , vol.79 , Issue.2 , pp. 159-178
    • Aydinalp, M.1    Ugursal, V.I.2    Fung, A.S.3
  • 19
    • 33745642470 scopus 로고    scopus 로고
    • Empirical prediction method of transmission heat loss in hot water plumbing
    • Cheng CL, Lee MC, Lin YH. Empirical prediction method of transmission heat loss in hot water plumbing. Energy Build 2006;38(10):1220-9.
    • (2006) Energy Build , vol.38 , Issue.10 , pp. 1220-1229
    • Cheng, C.L.1    Lee, M.C.2    Lin, Y.H.3
  • 20
    • 65449158959 scopus 로고    scopus 로고
    • Drainage demands of domestic washrooms in Hong Kong
    • Wong LT, Mui KW. Drainage demands of domestic washrooms in Hong Kong. Build Serv Eng Res Technol 2009;30(2):121-33.
    • (2009) Build Serv Eng Res Technol , vol.30 , Issue.2 , pp. 121-133
    • Wong, L.T.1    Mui, K.W.2
  • 23
    • 0016026826 scopus 로고
    • Household wastewater characterization
    • Ligman K, Hutzler N, Boyle WC. Household wastewater characterization. J Environ Eng Div 1974;100(2EE1):201-13.
    • (1974) J Environ Eng Div , vol.100 , Issue.2 EE1 , pp. 201-213
    • Ligman, K.1    Hutzler, N.2    Boyle, W.C.3
  • 24
    • 38849097608 scopus 로고    scopus 로고
    • Epistemic water consumption benchmarks for residential buildings
    • Wong LT, Mui KW. Epistemic water consumption benchmarks for residential buildings. Build Environ 2008;43(6):1031-5.
    • (2008) Build Environ , vol.43 , Issue.6 , pp. 1031-1035
    • Wong, L.T.1    Mui, K.W.2
  • 28
    • 44349191488 scopus 로고    scopus 로고
    • Stochastic modelling of water demand by domestic washrooms in residential tower blocks
    • Wong LT, Mui KW. Stochastic modelling of water demand by domestic washrooms in residential tower blocks. Water Environ J 2008;22(2):125-30.
    • (2008) Water Environ J , vol.22 , Issue.2 , pp. 125-130
    • Wong, L.T.1    Mui, K.W.2
  • 29
    • 0024090481 scopus 로고
    • Random number generators: good ones are hard to find
    • Park SK, Miller KW. Random number generators: good ones are hard to find. Commun ACM 1988;31(10):1192-201.
    • (1988) Commun ACM , vol.31 , Issue.10 , pp. 1192-1201
    • Park, S.K.1    Miller, K.W.2
  • 30
    • 18844422754 scopus 로고    scopus 로고
    • Determination of domestic flushing water consumption in Hong Kong
    • Wong LT, Mui KW. Determination of domestic flushing water consumption in Hong Kong. Facilities 2005;23(1/2):82-92.
    • (2005) Facilities , vol.23 , Issue.1-2 , pp. 82-92
    • Wong, L.T.1    Mui, K.W.2
  • 31
    • 41549156589 scopus 로고    scopus 로고
    • A transient ventilation demand model for air-conditioned offices
    • Wong LT, Mui KW. A transient ventilation demand model for air-conditioned offices. Appl Energy 2008;85(7):545-54.
    • (2008) Appl Energy , vol.85 , Issue.7 , pp. 545-554
    • Wong, L.T.1    Mui, K.W.2
  • 32
    • 38849167430 scopus 로고    scopus 로고
    • An approach to assessing the probability of unsatisfactory radon in air-conditioned offices of Hong Kong
    • Mui KW, Wong LT, Hui PS. An approach to assessing the probability of unsatisfactory radon in air-conditioned offices of Hong Kong. J Environ Radioactiv 2008;99(2):248-59.
    • (2008) J Environ Radioactiv , vol.99 , Issue.2 , pp. 248-259
    • Mui, K.W.1    Wong, L.T.2    Hui, P.S.3
  • 33
    • 62649143660 scopus 로고    scopus 로고
    • An energy performance assessment for indoor environmental quality (IEQ) acceptance in air-conditioned offices
    • Wong LT, Mui KW. An energy performance assessment for indoor environmental quality (IEQ) acceptance in air-conditioned offices. Energy Convers Manage 2009;50(5):1362-7.
    • (2009) Energy Convers Manage , vol.50 , Issue.5 , pp. 1362-1367
    • Wong, L.T.1    Mui, K.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.